<!-- 第 1 页 -->
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
62841-2-14
STANDARD FOR SAFETY
Electric Motor-Operated Hand-Held Tools,
Transportable Tools And Lawn And Garden
Machinery – Safety – Part 2-14: Particular
Requirements For Hand-Held Planers
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 2 页 -->
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 3 页 -->
AUGUST 12, 2016 −UL 62841-2-14
tr1
UL Standard for Safety for Electric Motor-Operated Hand-Held Tools, Transportable Tools And Lawn And
Garden Machinery – Part 2-14: Particular Requirements For Hand-Held Planers, UL 62841-2-14
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
First Edition, Dated August 12, 2016
Summary of Topics
Adoption Of The First Edition Of IEC 62841-2-14, Standard For Electric Motor-Operated
Hand-Held Tools, Transportable Tools And Lawn And Garden Machinery – Safety – Part
2-14: Particular Requirements for Hand-Held Planers, As The First Edition Of UL
62841-2-14
This standard is an adoption of IEC 62841-2-14, Edition 1, published by the IEC June 2015. There
are no technical national differences for this standard.
The new requirements are substantially in accordance with Proposal(s) on this subject dated March 18,
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or
transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise
without prior permission of UL.
UL provides this Standard ″as is″ without warranty of any kind, either expressed or implied, including but
not limited to, the implied warranties of merchantability or ﬁtness for any purpose.
In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,
including loss of proﬁts, lost savings, loss of data, or any other damages arising out of the use of or the
inability to use this Standard, even if UL or an authorized UL representative has been advised of the
possibility of such damage. In no event shall UL’s liability for any damage ever exceed the price paid for
this Standard, regardless of the form of the claim.
Users of the electronic versions of UL’s Standards for Safety agree to defend, indemnify, and hold UL
harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable
attorney’s fees) resulting from any error or deviation introduced while purchaser is storing an electronic
Standard on the purchaser’s computer system.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 4 页 -->
AUGUST 12, 2016 −UL 62841-2-14
tr2
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
No Text on This Page
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 5 页 -->
CSA Group
CAN/CSA-C22.2 No. 62841-2-14:16
First Edition
(IEC 62841-2-14:2015)
Underwriters Laboratories Inc.
UL 62841-2-14
First Edition
Electric Motor-Operated Hand-Held Tools, Transportable Tools And
Lawn And Garden Machinery – Safety – Part 2-14: Particular
Requirements For Hand-Held Planers
August 12, 2016
This national standard is based on publication IEC 62841-2-14 First Edition (2015).
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
ANSI/UL 62841-2-14-2016
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
Approved by

<!-- 第 6 页 -->
Commitment for Amendments
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
This standard is issued jointly by the Canadian Standards Association (operating as “CSA Group”) and
Underwriters Laboratories Inc. (UL). Comments or proposals for revisions on any part of the standard
may be submitted to CSA Group or UL at any time. Revisions to this standard will be made only after
processing according to the standards development procedures of CSA Group and UL. CSA Group and
UL will issue revisions to this standard by means of a new edition or revised or additional pages bearing
their date of issue.
ISBN 978-1-4883-0484-2 © 2016 CSA Group
All rights reserved. No part of this publication may be reproduced in any form whatsoever without the
prior permission of the publisher.
This Standard is subject to review ﬁve years from the date of publication, and suggestions for its
improvement will be referred to the appropriate committee. To submit a proposal for change, please
send the following information to inquires@csagroup.org and include ″Proposal for change″ in the
subject line: Standard designation (number); relevant clause, table, and/or ﬁgure number; wording of
the proposed change; and rationale for the change.
To purchase CSA Group Standards and related publications, visit CSA Group’s Online Store at
shop.csa.ca or call toll-free 1-800-463-6727 or 416-747-4044.
Copyright © 2016 Underwriters Laboratories Inc.
Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time.
Proposals should be submitted via a Proposal Request in UL’s On-Line Collaborative Standards
Development System (CSDS) at http://csds.ul.com.
This ANSI/UL Standard for Safety consists of the First Edition. The most recent designation of ANSI/UL
62841-2-14 as an American National Standard (ANSI) occurred on August 12, 2016. The ANSI
approval for this standard does not include the Cover Page, Transmittal Pages, Title Page, Preface
Page, National Difference Page or IEC Foreword.
Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time.
Proposals should be submitted via a Proposal Request in UL’s On-Line Collaborative Standards
Development System (CSDS) at http://csds.ul.com.
To purchase UL Standards, visit Comm 2000 at http://www.comm-2000.com/help/how_to_order.aspx
or call toll-free 1-888-853-3503.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 7 页 -->
CONTENTS
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
NATIONAL DIFFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
FOREWORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
1 Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
2 Normative references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
3 Terms and deﬁnitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
4 General requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
5 General conditions for the tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
6 Radiation, toxicity and similar hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
7 Classiﬁcation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
8 Marking and instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
9 Protection against access to live parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
10 Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
11 Input and current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
12 Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
13 Resistance to heat and ﬁre . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
14 Moisture resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
15 Resistance to rusting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
16 Overload protection of transformers and associated circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
17 Endurance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
18 Abnormal operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
19 Mechanical hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
19.111 Lift-off device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
20 Mechanical strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
21 Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
22 Internal wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
23 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
24 Supply connection and external ﬂexible cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
25 Terminals for external conductors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
26 Provision for earthing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
27 Screws and connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
28 Creepage distances, clearances and distances through insulation . . . . . . . . . . . . . . . . . . . . . . . .17
Annexes
Annex I (informative) Measurement of noise and vibration emissions
I.2 Noise test code (grade 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
I.2.4 Installation and mounting conditions of the power tools during noise tests . . . . . . . . . . .22
I.2.5 Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
I.3 Vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
I.3.3.2 Location of measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
I.3.5.3 Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
I.3.6.2 Declaration of the vibration total value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 8 页 -->
Annex K (normative) Battery tools and battery packs
Annex L (normative) Battery tools and battery packs provided with mains connection or
non-isolated sources
Bibliography
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM

<!-- 第 9 页 -->
Preface
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
This is the harmonized CSA Group and UL Standard For Electric Motor-Operated Hand-Held Tools,
Transportable Tools And Lawn And Garden Machinery – Safety – Part 2-14: Particular Requirements for
Hand-Held Planers. It is the First edition of CAN/CSA-C22.2 No. 62841-2-14 and the First edition of UL
62841-2-14.
This harmonized standard is based on IEC Publication 62841-2-14: First edition Standard For Electric
Motor-Operated Hand-Held Tools, Transportable Tools And Lawn And Garden Machinery – Safety – Part
2-14: Particular Requirements for Hand-Held Planers issued June 2015. IEC publication 62841-2-14 is
copyrighted by the IEC.
Note: At the time of publication, 62841-2-14:2015 is available from IEC in English only. CSA will publish the
French version when it becomes available from IEC.
This harmonized standard was prepared by CSA Group and Underwriters Laboratories Inc. (UL). The
efforts and support of the International Harmonization Committee (IHC) for the adoption of the IEC series
of standards for Hand-Held, Motor-Operated, and Transportable Tools and Lawn and Garden Machinery
UL are gratefully acknowledged.
This standard is considered suitable for use for conformity assessment within the stated scope of the
standard.
This standard was reviewed by the CSA Subcommittee on Safety of Hand-Held Motor-Operated Electric
Tools, under the jurisdiction of the CSA Technical Committee on Consumer and Commercial Products and
the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally
approved by the CSA Technical Committee.
This standard has been approved as a National Standard of Canada by the Standards Council of Canada
(SCC).
This standard has been approved by the American National Standards Institute (ANSI) as an American
National Standard.
Application of Standard
Where reference is made to a speciﬁc number of samples to be tested, the speciﬁed number is to be
considered a minimum quantity.
Note: Although the intended primary application of this standard is stated in its scope, it is important to note that
it remains the responsibility of the users of the standard to judge its suitability for their particular purpose.
This CAN/CSA-C22.2 No. 62841-2-14, Standard For Electric Motor-Operated Hand-Held Tools,
Transportable Tools And Lawn And Garden Machinery – Safety – Part 2-14: Particular Requirements for
Hand-Held Planers is to be used in conjunction with the First edition of CAN/CSA-C22.2 No. 62841-1. The
requirements for hand-held planers are contained in this Part 2 Standard and CAN/CSA-C22.2 No.
62841-1. Requirements of this Part 2 Standard, where stated, amend the requirements of
CAN/CSA-C22.2 No. 62841-1. Where a particular subclause of CAN/CSA-C22.2 No. 62841-1 is not
mentioned in CAN/CSA-C22.2 No. 62841-2-14, the CAN/CSA-C22.2 No. 62841-1 subclause applies.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 10 页 -->
This UL 62841-2-14 Standard For Electric Motor-Operated Hand-Held Tools, Transportable Tools And
Lawn And Garden Machinery – Safety – Part 2-14: Particular Requirements for Hand-Held Planers, is to
be used in conjunction with the First edition of UL 62841-1. The requirements for hand-held planers are
contained in this Part 2 Standard and UL 62841-1. Requirements of this Part 2 Standard, where stated,
amend the requirements of UL 62841-1. Where a particular subclause of UL 62841-1 is not mentioned in
UL 62841-2-14, the UL 62841-1 subclause applies.
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
Level of harmonization
This standard adopts the IEC text with editorial national differences.
This standard is published as an equivalent standard for CSA Group and UL.
An equivalent standard is a standard that is substantially the same in technical content, except as follows:
Technical national differences are allowed for codes and governmental regulations as well as those
recognized as being in accordance with NAFTA Article 905, for example, because of fundamental climatic,
geographical, technological, or infrastructural factors, scientiﬁc justiﬁcation, or the level of protection that
the country considers appropriate. Presentation is word for word except for editorial changes.
All national differences from the IEC text are included in the CSA Group and UL versions of the standard.
While the technical content is the same in each organization’s version, the format and presentation may
differ.
Reasons for Differences From IEC
National Differences from the IEC are being added in order to address safety and regulatory situations
present in the US and Canada.
Interpretations
The interpretation by the standards development organization of an identical or equivalent standard is
based on the literal text to determine compliance with the standard in accordance with the procedural
rules of the standards development organization. If more than one interpretation of the literal text has been
identiﬁed, a revision is to be proposed as soon as possible to each of the standards development
organizations to more accurately reﬂect the intent.
IEC Copyright
For CSA Group, the text, ﬁgures, and tables of International Electrotechnical Commission Publication IEC
62841-2-14 Electric Motor-Operated Hand-Held Tools, Transportable Tools And Lawn And Garden
Machinery – Safety – Part 2-14: Particular Requirements for Hand-Held Planers, copyright 2015, are used
in this standard with the consent of the International Electrotechnical Commission. The IEC Foreword is
not a part of the requirements of this standard but is included for information purposes only.
For UL, the text, ﬁgures and tables of IEC publication IEC 62841-2-14, Standard For Electric
Motor-Operated Hand-Held Tools, Transportable Tools And Lawn And Garden Machinery – Safety – Part
2-14: Particular Requirements for Hand-Held Planers, copyright 2015 are used in this standard with the
consent of the IEC and the American National Standards Institute (ANSI). The IEC copyrighted material
has been reproduced with permission from ANSI. ANSI should be contacted regarding the reproduction of
any portion of the IEC material. The IEC Foreword is not a part of the requirements of this standard but
is included for information purposes only. Copies of IEC Publication IEC 62841-2-14 may be purchased
from ANSI, 25 West 43rd Street, 4th Floor, New York, New York, 10036, (212) 642- 4900.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 11 页 -->
NATIONAL DIFFERENCES
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
National Differences from the text of International Electrotechnical Commission (IEC) Publication IEC
62841-2-14, Electric Motor-Operated Hand-Held Tools, Transportable Tools And Lawn And Garden
Machinery – Safety – Part 2-14: Particular Requirements for Hand-Held Planers) copyright 2015 are
indicated by notations (differences) and are presented in bold text. The national difference type is included
in the body.
There are ﬁve types of National Differences as noted below. The difference type is noted on the ﬁrst line
of the National Difference in the standard. The standard may not include all types of these National
Differences.
DR – These are National Differences based on the national regulatory requirements.
D1 – These are National Differences which are based on basic safety principles and
requirements, elimination of which would compromise safety for consumers and users of
products.
D2 – These are national differences from IEC requirements based on existing safety practices.
These requirements reﬂect national safety practices, where empirical substantiation (for the IEC
or national requirement) is not available or the text has not been included in the IEC standard.
DC – These are National Differences based on the component standards and will not be
deleted until a particular component standard is harmonized with the IEC component standard.
DE – These are National Differences based on editorial comments or corrections.
Each national difference contains a description of what the national difference entails. Typically one of the
following words is used to explain how the text of the national difference is to be applied to the base IEC
text:
Addition / Add - An addition entails adding a complete new numbered clause, subclause,
table, ﬁgure, or annex. Addition is not meant to include adding select words to the base IEC
text.
Modiﬁcation / Modify - A modiﬁcation is an altering of the existing base IEC text such as the
addition, replacement or deletion of certain words or the replacement of an entire clause,
subclause, table, ﬁgure, or annex of the base IEC text.
Deletion / Delete - A deletion entails complete deletion of an entire numbered clause,
subclause, table, ﬁgure, or annex without any replacement text.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 12 页 -->
INTERNATIONAL ELECTROTECHNICAL COMMISSION
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
ELECTRIC MOTOR-OPERATED HAND-HELD TOOLS, TRANSPORTABLE TOOLS AND LAWN AND
GARDEN MACHINERY – SAFETY – PART 2-14: PARTICULAR REQUIREMENTS FOR HAND-HELD
PLANERS
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national
electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions
concerning standardization in the electrical and electronic ﬁelds. To this end and in addition to other activities, IEC publishes
International Standards, Technical Speciﬁcations, Technical Reports, Publicly Available Speciﬁcations (PAS) and Guides (hereafter
referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and nongovernmental organizations
liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of
opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that
sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be
held responsible for the way in which they are used or for any misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the
maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the
corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certiﬁcation bodies provide conformity assessment services
and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent
certiﬁcation bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its
technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature
whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or
reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the
correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC
shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62841-2-14 has been prepared by IEC technical committee 116: Safety of
motor-operated electric tools.
The text of this standard is based on the following documents:
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 13 页 -->
FDIS
Report on voting
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
116/222/FDIS
116/236/RVD
Full information on the voting for the approval of this standard can be found in the report on voting
indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
This Part 2-14 is to be used in conjunction with the ﬁrst edition of IEC 62841-1:2014.
This Part 2-14 supplements or modiﬁes the corresponding clauses in IEC 62841-1, so as to convert it into
the IEC Standard: Particular requirements for hand-held planers.
Where a particular subclause of Part 1 is not mentioned in this Part 2-14, that subclause applies as far as
reasonable. Where this standard states ″addition″, ″modiﬁcation″ or ″replacement″, the relevant text in
Part 1 is to be adapted accordingly.
The following print types are used:
– requirements: in roman type
– test speciﬁcations: in italic type;
NOTES: IN SMALLER ROMAN TYPE
The terms deﬁned in Clause 3 are printed in bold typeface.
Subclauses, notes and ﬁgures which are additional to those in Part 1 are numbered starting from 101.
A list of all parts of the IEC 62841 series, under the general title: Electric motor-operated hand-held tools,
transportable tools and lawn and garden machinery – Safety, can be found on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until the stability
date indicated on the IEC web site under ″http://webstore.iec.ch″ in the data related to the speciﬁc
publication. At this date, the publication will be
• reconﬁrmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.
NOTE The attention of National Committees is drawn to the fact that equipment manufacturers and testing organizations may need
a transitional period following publication of a new, amended or revised IEC publication in which to make products in accordance
with the new requirements and to equip themselves for conducting new or revised tests.
It is the recommendation of the committee that the content of this publication be adopted for implementation nationally not earlier
than 36 months from the date of publication.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 14 页 -->
101DV
DE Modiﬁcation: Add the following to the IEC Foreword:
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
The numbering system in the standard uses a space instead of a comma to indicate
thousands and uses a comma instead of a period to indicate a decimal point. For example,
1 000 means 1,000 and 1,01 means 1.01.
102DV
DE Modiﬁcation: Add the following to the IEC Foreword:
For this Standard, all references to ″Part 1″ refer to CAN/CSA-C22.2 No. 62841-1 and UL
62841-1.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 15 页 -->
ELECTRIC MOTOR-OPERATED HAND-HELD TOOLS,
TRANSPORTABLE TOOLS AND LAWN AND GARDEN MACHINERY –
SAFETY – PART 2-14: PARTICULAR REQUIREMENTS FOR
TRANSPORTABLE HAND-HELD PLANERS
1 Scope
This clause of Part 1 is applicable, except as follows:
Addition:
This part of IEC 62841 applies to planers.
2 Normative references
This clause of Part 1 is applicable.
3 Terms and deﬁnitions
This clause of Part 1 is applicable, except as follows:
Additional deﬁnitions:
3.101 planer: tool intended for removing surface material, equipped with a rotating cutting head where
the axis of rotation of the cutting head is parallel to the plane of the base plate, which is the part
supporting the planer on the workpiece
Note 1 to entry: The base plate consists of a ﬁxed shoe and an adjustable shoe that determines the depth of cut.
3.102 lift-off device: device which keeps the blade(s) from making contact with a ﬂat surface when the
base plate of the planer is attempted to be placed on the ﬂat surface
3.103 cutting head: assembly of blades, cutter block, blade ﬁxing elements, relevant screws and spindle,
the whole being ready for working
4 General requirements
This clause of Part 1 is applicable.
5 General conditions for the tests
This clause of Part 1 is applicable, except as follows:
5.17 Addition:
The mass of the tool includes the cutting head including blades and the dust extraction adapter, if any.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM

<!-- 第 16 页 -->
6 Radiation, toxicity and similar hazards
This clause of Part 1 is applicable.
7 Classiﬁcation
This clause of Part 1 is applicable.
8 Marking and instructions
This clause of Part 1 is applicable, except as follows:
8.1 Addition:
– rated no-load speed.
8.3 Addition:
– direction of rotation of the working spindle. This shall be indicated by an arrow, raised or
sunk, or by other means no less visible and indelible.
8.14.1 Addition:
For planers, the additional safety instructions as speciﬁed in 8.14.1.101 shall be given. This part may be
printed separately from the ″General power tool safety warnings″.
8.14.1.101 Safety instructions for planers
a) Wait for the cutter to stop before setting the tool down. An exposed rotating cutter may
engage the surface leading to possible loss of control and serious injury.
b) Hold the power tool by insulated gripping surfaces, because the cutter may contact its
own cord. Cutting a ″live″ wire may make exposed metal parts of the power tool ″live″ and
could give the operator an electric shock.
c) Use clamps or another practical way to secure and support the workpiece to a stable
platform. Holding the workpiece by your hand or against the body leaves it unstable and may
lead to loss of control.
8.14.2 b) Addition:
101) instructions on how to adjust the entire range of the depth of cut;
102) instruction on the correct use of the dust collection system.
8.14.2 c) Addition:
101) information about types of cutting heads which can be used, if applicable;
102) instructions for the changing of the blades and their adjustment to the correct position;
103) instruction on how to properly clean/clear the chip ejection opening.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM

<!-- 第 17 页 -->
9 Protection against access to live parts
This clause of Part 1 is applicable.
10 Starting
This clause of Part 1 is applicable.
11 Input and current
This clause of Part 1 is applicable.
12 Heating
This clause of Part 1 is applicable.
13 Resistance to heat and ﬁre
This clause of Part 1 is applicable.
14 Moisture resistance
This clause of Part 1 is applicable.
15 Resistance to rusting
This clause of Part 1 is applicable.
16 Overload protection of transformers and associated circuits
This clause of Part 1 is applicable.
17 Endurance
This clause of Part 1 is applicable, except as follows:
17.101 If a lift-off device is provided to meet the requirements of 18.8 or 21.18.1.1, it shall be sufficiently
durable.
Compliance is checked by a new tool sample completing the following test.
The planer is to be set in horizontal position. The lift-off device is cycled through its intended range of
operation for 50 000 cycles. This sequence is repeated at a rate not less than 10 cycles per minute.
After completion of the cycling test as speciﬁed above, the planer shall then comply with 19.111.
18 Abnormal operation
This clause of Part 1 is applicable, except as follows:
18.8 Replacement of Table 4 by the following:
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM

<!-- 第 18 页 -->
Table 4 – Required performance levels
Power switch – prevent unwanted switch-on
c
Power switch – provide desired switch-off for planers with lift-off device
a
Power switch – provide desired switch-off for planers without lift-off device
b
Any electronic control to pass the test of 18.3
a
Overspeed prevention to prevent output speed above 130% of rated no-load
speed
Provide desired direction of rotation
a
Prevent exceeding thermal limits as in Clause 18
a
Prevent self-resetting as required in 23.3
b
Lock-off function as required by 21.18.1.2
b
19 Mechanical hazards
This clause of Part 1 is applicable, except as follows:
19.1 Addition:
For the requirements given in 19.107, 19.108 and 19.109, only the test probe shown in Figure 102 is used.
19.4.101 Planers with a mass according to 5.17 exceeding 3 kg shall have at least two handles. The
auxiliary handle, if any, may also be used for the depth-of-cut setting, provided the adjustment of depth of
cut is achieved by a rotary action.
Compliance is checked by inspection and by measurement.
19.101 The cutting head shall be cylindrically shaped except for the blades, the gullet and the blade
clamping means.
The maximum gullet width s shall be
smax = 0,235 d + 7,2 mm
where d is the diameter of the rotating circle of the cutting edges. See Figure 101.
Compliance is checked by inspection and by measurement.
19.102 The blades when aligned with the ﬁxed shoe shall not project by more than 1,1 mm radially
beyond the cutter block (as per dimension ″a″ in Figure 101).
Compliance is checked by measurement.
19.103 At any depth of cut, the distance ″b″ (see Figure 101) between the rotating circle of the cutting
edges and the trailing edge on the adjustable shoe shall not exceed 5 mm measured radially.
Compliance is checked by inspection and by measurement.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
DISTRIBUTION WITHOUT PERMISSION FROM UL
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
Type and purpose of SCF
Minimum Performance Level (PL)
b

<!-- 第 19 页 -->
19.104 The blades shall be secured in the cutter block in such a way that friction alone is not relied upon
to prevent the radial ejection of the blades.
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
Compliance is checked by inspection.
19.105 Cutting heads shall be designed and made of such materials that they withstand the forces and
loads expected in normal use.
Compliance is checked by the following test:
An overspeed test shall be made on a sample cutting head, equipped with blades for the largest cutting
diameter and the largest cutting edge width, the test speed being 1,5 times the rated no-load speed. If
applicable, tension elements such as clamping screws shall be tightened in accordance with the
instructions required by 8.14.2 b).
After the test, the cutting head shall not be deformed or cracked, no screws shall be loosened and
displacements of separable parts shall be less than speciﬁed in the test procedure.
The test procedure is as follows:
1) Measure the cutting head dimensions.
2) Bring the cutting head to the rated no-load speed, for 1 min.
3) Stop and re-measure the cutting head; measured displacements of the separable parts of
the cutting head shall not be greater than 0,15 mm.
4) Bring the cutting head to the test speed, for 1 min.
5) Stop and re-measure the cutting head and compare the results with those obtained from
step 3. The compared displacements shall not exceed 0,15 mm.
19.106 Clamping screws or bolts shall not project beyond the cutter block as shown in Figure 101.
Compliance is checked by inspection.
19.107 It shall not be possible to inadvertently touch rotating parts from the sides of the planer, except
for the cases covered by 19.108.
Compliance is checked by the following test:
The planer is set to minimum depth of cut and is positioned with the shoes resting on a ﬂat surface that
extends beyond the planer by at least 100 mm in all directions. Any lift-off device is disabled. The
accessibility is checked by means of the test probe shown in Figure 102 with a force not exceeding 5 N.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 20 页 -->
19.108 Planers with rabbeting facilities shall be provided with a guard that avoids inadvertent contact at
the sides with the blades.
NOTE Rabbeting is also known as rebating.
Compliance is checked by inspection and by the following test:
The planer is set to minimum depth of cut and is positioned with the shoes resting on a ﬂat surface that
extends beyond the planer by at least 100 mm in all directions. Any lift-off device is disabled. The
accessibility is checked by means of the test probe shown in Figure 102 without any force.
19.109 It shall not be possible to touch the blades through the chip ejection opening.
Compliance is checked by testing all apertures for chip ejection with the test probe of Figure 102. It shall
not be possible to touch the blades in the cutting head at any angle of the probe.
19.110 Planers shall stop within 10 s after switching off.
Compliance is checked by inspection and by measurement.
19.111 Lift-off device
19.111.1 If a lift-off device is provided to meet the requirements of 18.8 or 21.18.1.1, it shall meet the
requirements of 19.111.2 and 19.111.3, which are checked only after completing the endurance test of
17.101.
19.111.2 If a lift-off device is provided, it shall be designed so that
– it is automatically activated, when the planer is lifted up from a horizontal surface; and
– the blade(s) do not make contact, when the planer is set at maximum depth of cut in
accordance with 8.14.2 b) 101) and placed on a horizontal surface.
Compliance is checked by inspection.
19.111.3 A lift-off device shall provide sufficient stability.
Compliance is checked by the following test:
The planer is set to maximum depth of cut in accordance with 8.14.2 b) 101) and with the supply cord,
if any, removed. The planer is then placed on a ﬂat board of medium density ﬁbreboard (MDF) having a
density of 650 kg/m3 to 850 kg/m3 that is inclined at an angle of 10°, such that the rear of the planer is
nearest to the high side of the board and allowed to rest freely for 10 s to 12 s. During the test, the planer
is permitted to slide, however, the liftoff device shall not collapse such that the planer blades come into
contact with the board.
20 Mechanical strength
This clause of Part 1 is applicable.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM

<!-- 第 21 页 -->
21 Construction
This clause of Part 1 is applicable, except as follows:
21.18.1.1 Addition:
Planers whose blade(s) make contact with a ﬂat surface when the base plate is placed on the ﬂat surface
and without a lift-off device are regarded as tools having a risk associated with continued locked-on
operation.
NOTE In Europe (EN 62841-2-14), the above text is replaced by the following:
For planers, the switch shall not have any locking device to lock it in the ″on″ position.
21.18.1.2 Addition:
Planers are regarded as tools having a risk associated with inadvertent starting.
21.35 This subclause of Part 1 is applicable.
22 Internal wiring
This clause of Part 1 is applicable.
23 Components
This clause of Part 1 is applicable.
24 Supply connection and external ﬂexible cords
This clause of Part 1 is applicable.
25 Terminals for external conductors
This clause of Part 1 is applicable.
26 Provision for earthing
This clause of Part 1 is applicable.
27 Screws and connections
This clause of Part 1 is applicable.
28 Creepage distances, clearances and distances through insulation
This clause of Part 1 is applicable.
This is generated text for ﬁgtxt.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM

<!-- 第 22 页 -->
This is generated text for ﬁgtxt.
Figure 101 – Examples of cutting heads with basic dimensions
a) Example 1 and explanation of basic dimensions
Key
1 ﬁxed shoe
2 adjustable shoe
3 trailing edge
a radial projection of the blades beyond the cutter block
b distance between the rotating circle of the cutting edges and the trailing edge of the adjustable shoe
d diameter of the rotating circle of the cutting edges
s gullet width
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM

<!-- 第 23 页 -->
This is generated text for ﬁgtxt.
Figure 101 – Examples of cutting heads with basic dimensions
b) Example 2
Key
1 ﬁxed shoe
2 adjustable shoe
3 trailing edge
a radial projection of the blades beyond the cutter block
b distance between the rotating circle of the cutting edges and the trailing edge of the adjustable shoe
d diameter of the rotating circle of the cutting edges
s gullet width
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM

<!-- 第 24 页 -->
Figure 102 – Test probe
Key
1 handle section
2 test section
3 probe’s ﬂange
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
Dimensions in millimetres

<!-- 第 25 页 -->
Annexes
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
The annexes of Part 1 are applicable except as follows.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 26 页 -->
Annex I
(informative)
Measurement of noise and vibration emissions
NOTE In Europe (EN 62841-2-14), Annex I is normative.
I.2 Noise test code (grade 2)
This clause of Part 1 is applicable except as follows:
I.2.4 Installation and mounting conditions of the power tools during noise tests
Addition:
Planers are held and used as speciﬁed in I.2.5.
I.2.5 Operating conditions
Addition:
Planers are tested under load observing the conditions shown in Table I.101.
The temperature requirements of 5.6 are not applicable.
Table I.101 – Test conditions
Orientation
Planing along a horizontal surface of a softwood workpiece free of knots and having a residual
moisture not exceeding 14 %.
To prevent absorption of airborne noise, the resilient material shall either
– not extend the contact area between workpiece and test bench; or
– be of non airborne-sound absorbing material, such as rubber.
If a parallel guide is provided, this may be used.
NOTE Examples of softwood are pine and ﬁr.
Tool bit
Blade as speciﬁed for planing softwood. The depth of cut shall be set to maximum capacity.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
DISTRIBUTION WITHOUT PERMISSION FROM UL
Table I.101 – Test conditions Continued on Next Page
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
The workpiece shall have a minimum length of 600 mm, a minimum height of 90 mm and a width B,
where B is the maximum planing width of the tool minus (15 ±2) mm.
The workpiece shall be supported on resilient material and ﬁxed vertically by screws, clamps, air
cylinders or the like to a test bench of Figure I.1, see Figure I.101. For the ﬁxing, the workpiece may
have recesses or the like; an example is shown in Figure I.101. The resilient material shall be
mounted so that it does not have any signiﬁcant resonance in the frequency range that can
inﬂuence the test result.

<!-- 第 27 页 -->
Table I.101 – Test conditions Continued
Feed force
As necessary to achieve a constant feed rate resulting in 10 s to 15 s planing time for one test
cycle (600 mm). Equal forces are applied to the main handle and the auxiliary handle, if applicable,
avoiding excessive gripping forces.
Test cycle
Planing the complete length of 600 mm at maximum depth of cut.
I.3 Vibration
This clause of Part 1 is applicable except as follows:
I.3.3.2 Location of measurement
Addition:
Figures I.102 shows the positions on the main handle and the auxiliary handle, if applicable.
I.3.5.3 Operating conditions
Addition:
Planers are tested under load according to the conditions shown in Table I.101.
I.3.6.2 Declaration of the vibration total value
Addition:
The vibration total value ah of the handle with the highest emission and the uncertainty K shall be
declared.
This is generated text for ﬁgtxt.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
DISTRIBUTION WITHOUT PERMISSION FROM UL
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
However, if it is not possible to plane the whole surface length within the given time, because the
planer may stall, a longer test cycle time is permitted using a feed force as high as possible without
stalling the planer.
The measurement takes place over a length of approximately 400 mm that does not include the
ends of the workpiece.

<!-- 第 28 页 -->
This is generated text for ﬁgtxt.
Figure I.101 – Test set-up for planers
a) Side view
Key
1 test bench of Figure I.1
2 resilient material
3 workpiece
4 ﬁxing means (e.g. clamps)
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM

<!-- 第 29 页 -->
This is generated text for ﬁgtxt.
Figure I.101 – Test set-up for planers
b) Front view
Key
1 test bench of Figure I.1
2 resilient material
3 workpiece
4 ﬁxing means (e.g. clamps)
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM

<!-- 第 30 页 -->
Figure I.102 – Position of transducers
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 31 页 -->
Annex K
(normative)
Battery tools and battery packs
K.1 Scope
Addition:
All clauses of this Part 2-14 apply unless otherwise speciﬁed in this annex.
K.8.14.1.101 Item b) is not applicable.
K.12.2.1 This subclause is not applicable.
K.20.5 This subclause is not applicable.
K.21.18.1.2 Addition:
Two separate and dissimilar actions shall be necessary before the motor is switched on (e.g. a power
switch which has to be pushed in before it can be moved laterally to close the contacts to start the motor).
It shall not be possible to achieve these two actions with a single grasping motion or a straight line motion.
Compliance is checked by inspection and by manual test.
K.21.30 This subclause is not applicable.
NOTE In Europe (EN 62841-2-14), the following additional subclause applies:
K.21.18.Z101 Isolation device
Planers with an integral battery shall be equipped with an isolation device to prevent the risk of injury
from mechanical hazards during user maintenance that
– ensures a reliable disconnection of at least one pole of the battery from the relevant load(s);
– has a reliable mechanical link between the manual control and the disconnecting element(s);
– is equipped with an unambiguous indication of the state of the disconnection device which
corresponds to each position of its manual control (actuator);
– protects against accidental reconnection.
NOTE 1 Examples of methods to achieve this disconnection include removable jumpers, removable batteries or a
electromechanical power switch with a direct mechanical link between the actuator and the contact.
NOTE 2 The risk of accidental reconnection for a power switch is addressed by the requirement of 21.18.1.2. The other examples
in Note 1 achieve this by the necessary actions for reconnection.
Compliance is checked by inspection.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM

<!-- 第 32 页 -->
Annex L
(normative)
Battery tools and battery packs provided with mains connection or non-isolated sources
L.1 Scope
Addition:
All clauses of this Part 2-14 apply unless otherwise speciﬁed in this annex.
L.21.18.1.2 Addition:
Two separate and dissimilar actions shall be necessary before the motor is switched on (e.g. a power
switch which has to be pushed in before it can be moved laterally to close the contacts to start the motor).
It shall not be possible to achieve these two actions with a single grasping motion or a straight line motion.
Compliance is checked by inspection and by manual test.
NOTE In Europe (EN 62841-2-14), the following additional subclause applies:
L.21.18.Z101 Isolation device
Planers with an integral battery shall be equipped with an isolation device to prevent the risk of injury
from mechanical hazards during user maintenance that
– ensures a reliable disconnection of at least one pole of the battery from the relevant load(s);
– has a reliable mechanical link between the manual control and the disconnecting element(s);
– is equipped with an unambiguous indication of the state of the disconnection device which
corresponds to each position of its manual control (actuator);
– protects against accidental reconnection.
NOTE 1 Examples of methods to achieve this disconnection include removable jumpers, removable batteries or a
electromechanical power switch with a direct mechanical link between the actuator and the contact.
NOTE 2 The risk of accidental reconnection for a power switch is addressed by the requirement of 21.18.1.2. The other examples
in Note 1 achieve this by the necessary actions for reconnection.
Compliance is checked by inspection.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM

<!-- 第 33 页 -->
Bibliography
The bibliography of Part 1 is applicable.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM

<!-- 第 34 页 -->
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
No Text on This Page
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 35 页 -->
This document is only permissible for use by claire.hu@intertek.com of Intertek, Electrical/Wireless, Qinzhou, Shanghai, China. 1/5/2017 5:06:55 AM
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR