<!-- 第 1 页 -->
UL 60745-1
STANDARD FOR SAFETY
Hand-Held Motor-Operated Electric
Tools – Safety – Part 1: General
Requirements

<!-- 第 2 页 -->
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 3 页 -->
APRIL 30, 2020 - UL 60745-1
tr1
UL Standard for Safety for Hand-Held Motor-Operated Electric Tools – Safety – Part 1: General
Requirements, UL 60745-1
Fourth Edition, Dated July 31, 2007
SUMMARY OF TOPICS
The revisions dated of ANSI/UL 60745-1 dated April 30, 2020 includes the following changes in
requirements:
Addition Of National Differences To Clause L.18.201 To Align Abnormal Testing
Requirements With The Inherent System Protections Of Electronically Commutated Motors
Addition Of A National Difference To Clause 8.12.1 To Allow Substituting The Marking And
Instruction Requirements With Those In The Standard For Electric Motor-Operated Hand-
Held Tools, Transportable Tools And Lawn And Garden Machinery – Safety – Part 1: General
Requirements, UL 62841-1
Text that has been changed in any manner or impacted by UL's electronic publishing system is marked
with a vertical line in the margin.
The new and revised requirements are substantially in accordance with Proposal(s) on this subject dated
January 24, 2020.
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or
transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise
without prior permission of UL.
UL provides this Standard "as is" without warranty of any kind, either expressed or implied, including but
not limited to, the implied warranties of merchantability or fitness for any purpose.
In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,
including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or the
inability to use this Standard, even if UL or an authorized UL representative has been advised of the
possibility of such damage. In no event shall UL's liability for any damage ever exceed the price paid for
this Standard, regardless of the form of the claim.
Users of the electronic versions of UL's Standards for Safety agree to defend, indemnify, and hold UL
harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable
attorney's fees) resulting from any error or deviation introduced while purchaser is storing an electronic
Standard on the purchaser's computer system.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 4 页 -->
tr2
APRIL 30, 2020 - UL 60745-1
No Text on This Page
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 5 页 -->
CSA Group
CAN/CSA-C22.2 No. 60745-1-07
Third Edition
(IEC 60745-1:2006, MOD)
Underwriters Laboratories Inc.
UL 60745-1
Fourth Edition
Hand-Held Motor-Operated Electric Tools – Safety – Part 1:
General Requirements
July 31, 2007
(Title Page Reprinted: April 30, 2020)
This national standard is based on publication IEC 60745-1, 4th Edition (2006).
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
ANSI/UL 60745-1-20i20

<!-- 第 6 页 -->
Commitment for Amendments
This standard is issued jointly by the Canadian Standards Association (operating as “CSA Group”) and
Underwriters Laboratories Inc. (UL). Comments or proposals for revisions on any part of the standard
may be submitted to CSA Group or UL at anytime. Revisions to this standard will be made only after
processing according to the standards development procedures of CSA Group and UL. CSA Group and
UL will issue revisions to this standard by means of a new edition or revised or additional pages bearing
their date of issue.
ISBN 1-55436-444-2 © 2007 Canadian Standards Association
All rights reserved. No part of this publication may be reproduced in any form whatsoever without the
prior permission of the publisher.
This Standard is subject to review within five years from the date of publication, and suggestions for its
improvement will be referred to the appropriate committee. The technical content of IEC and ISO
publications is kept under constant review by IEC and ISO. To submit a proposal for change, please
send the following information to inquiries@csagroup. org and include "Proposal for change" in the
subject line: Standard designation (number); relevant clause, table, and/or figure number; wording of
the proposed change; and rationale for the change.
To purchase CSA Group Standards and related publications, visit CSA Group's Online Store at
istore.csagroup.org or call toll-free 1-800-463-6727 or 416-747-4044.
Copyright © i2020 Underwriters Laboratories Inc.
UL's Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard
should be altered in any way. All of UL's Standards and all copyrights, ownerships, and rights regarding
those Standards shall remain the sole and exclusive property of UL.
This ANSI/UL Standard for Safety consists of the Fourth editioni including revisions through
iApril 30,
2020. The most recent designation of ANSI/UL 60745-1 as an American National Standard (ANSI)
occurred on iApril 30, 2020. ANSI approval for a standard does not include the Cover Page, Transmittal
Pages, Title Page (front and back), or the Preface. The National Difference Page and IEC Foreword are
also excluded from the ANSI approval of IEC-based standards.
Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time.
Proposals should be submitted via a Proposal Request in UL's On-Line Collaborative Standards
Development System (CSDS) at https://csds.ul.com.
To purchase UL Standards, visit UL's Standards Sales Site at http://www. shopulstandards.
com/HowToOrder.aspx or call toll-free 1-888-853-3503.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 7 页 -->
CONTENTS
Preface .............................................................................................................................................9
NATIONAL DIFFERENCES..............................................................................................................11
FOREWORD ...................................................................................................................................13
INTRODUCTION..............................................................................................................................17
Scope .................................................................................................................................19
1DV
Addition: Add the following paragraph: .....................................................................19
Normative references...........................................................................................................20
2DV
Modification: Add the following: ...............................................................................20
Terms and Definitions...........................................................................................................27
3.57DV
Modification: Add the following to the end of the definition:....................................31
General requirements...........................................................................................................32
General conditions for the tests.............................................................................................32
Void ....................................................................................................................................34
Classification .......................................................................................................................34
Marking and instructions.......................................................................................................34
8.1DV
Modification: Add the following: ............................................................................35
8.1DV.1
Addition: Add the following clause: .....................................................................35
8.1DV.2
Modification: Add the following paragraph:..........................................................36
8.12.1DV
Modification: Add the following paragraph:........................................................40
8.12.1DV.1
Modification: Add the following paragraph to Clause 8.12.1: ............................41
8.13DV
Modification: Add the following: ..........................................................................45
8.13DV.1
Modification: Add the following subclause: ........................................................46
Protection against access to live parts ...................................................................................47
Starting .............................................................................................................................48
Input and current ................................................................................................................49
Heating .............................................................................................................................49
Leakage current.................................................................................................................53
13.2DV
Modification: Replace the class I tools item with the following:...............................54
Moisture resistance ............................................................................................................54
Electric strength .................................................................................................................57
Overload protection of transformers and associated circuits ..................................................59
Endurance.........................................................................................................................59
Abnormal operation............................................................................................................60
18.12DV
Modification: Replace Clause 18.12 with Clauses 18.12DV.1 to 18.12DV.3 ..........65
Mechanical hazards ...........................................................................................................67
Mechanical strength ...........................................................................................................68
Construction ......................................................................................................................69
Internal wiring ....................................................................................................................77
22.3DV
Modification: Delete the fourth paragraph and replace the third paragraph with the
following: .......................................................................................................................77
22.4DV
Modification: Replace the first paragraph with the following:..................................78
Components......................................................................................................................78
Supply connection and external flexible cords ......................................................................80
24.1DV
Modification: Add the following sentence: ............................................................81
24.4DV
Modification: Replace 24.4 with the following: ......................................................82
Table 6DV
Modification: Replace Table 6 with the following:..............................................82
24.6DV
Modification: Replace the first paragraph with the following:..................................83
Terminals for external conductors ........................................................................................88
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Table 8DV
Modification: Replace Table 8 with the following:..............................................89

<!-- 第 8 页 -->
Provision for earthing..........................................................................................................91
26.1DV
Modification: Add the following sentence to the fifth paragraph of Clause 26.1:.......91
26.2DV
Modification: Add the following paragraphs:.........................................................92
Screws and connections.....................................................................................................93
27.3DV
Modification: .....................................................................................................95
Creepage distances, clearances and distances through insulation .........................................95
Resistance to heat, fire and tracking ....................................................................................99
29.1DV
Modification: Replace the last paragraph with the following:................................100
29.2DV
Modification: Replace Clause 29.2 with the following:.........................................100
Resistance to rusting........................................................................................................101
Radiation, toxicity and similar hazards ...............................................................................102
Annex A (normative) Measurement of creepage distances and clearances .................................. 114
A.1
Measurement of creepage distances and clearances......................................................... 114
Annex B (normative) Motors not isolated from the supply mains and having basic insulation not
designed for the rated voltage of the tool........................................................................ 119
B.1
Scope ............................................................................................................................ 119
B.9
Protection against access to live parts .............................................................................. 119
B.12
Heating ........................................................................................................................ 119
B.15
Electric strength............................................................................................................ 119
B.18
Abnormal operation....................................................................................................... 119
B.21
Construction ................................................................................................................. 119
B.28
Creepage distances, clearances and distances through insulation....................................120
Annex C Void ................................................................................................................................121
Annex D Void ................................................................................................................................122
Annex E Void ................................................................................................................................123
Annex F (normative) Needle-flame test.........................................................................................124
Description of the test apparatus .........................................................................................124
5.4
Specified layer.......................................................................................................124
Severities ..........................................................................................................................124
Test procedure...................................................................................................................124
9.3
Number of test specimens ......................................................................................124
Evaluation of test results ...................................................................................................124
Annex G (normative) Proof tracking test.......................................................................................125
Test specimen ...................................................................................................................125
Test apparatus...................................................................................................................125
Basic test procedure...........................................................................................................125
Determination of erosion.....................................................................................................125
Determination of proof tracking index (PTI).........................................................................125
Determination of comparative tracking index (CTI) ..............................................................125
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 9 页 -->
Annex H Void ................................................................................................................................126
Annex I (normative) Switches .......................................................................................................127
Marking and documentation ...............................................................................................127
Mechanism......................................................................................................................127
Insulation resistance and dielectric strength .......................................................................127
Endurance.......................................................................................................................127
17.2.4.4
Test at accelerated speed (TC4) ......................................................................128
Clearances, creepage distances, solid insulation and coatings of rigid printed board
assemblies.....................................................................................................................128
Annex J(informative) Selection and sequence of the tests of clause 29 .......................................129
Annex K (normative) Battery tools and battery packs...................................................................130
K.1
Scope ...........................................................................................................................130
K.2
Normative references......................................................................................................130
K.3
Terms and Definitions......................................................................................................130
K.5
General conditions for the tests........................................................................................131
K.7
Classification..................................................................................................................131
K.8
Marking and instructions..................................................................................................131
K.8.1DV
Modification: Add the following after the last dashed item: .................................132
K.8.12.1.1DV
Modification: Add the following paragraph to Clause K.8.12.1.1:.................132
K.9
Protection against electric shock ......................................................................................133
K.10
Starting ........................................................................................................................133
K.11
Input and current...........................................................................................................133
K.12
Heating ........................................................................................................................133
K.13
Leakage current............................................................................................................134
K.14
Moisture resistance.......................................................................................................134
K.15
Electric Strength ...........................................................................................................134
K.15.1DV
Modification: Add the following sentences: ....................................................134
K.16
Overload protection of transformers and associated circuits .............................................134
K.17
Endurance....................................................................................................................135
K.18
Abnormal operation.......................................................................................................135
K.18.1DV.1
Modification: Replace Item (b) of Clause K.18.1 with the following: ................135
K.18.1.DV.2
Modification: Replace Item (c) of Clause K.18.1 with the following: ...............135
K.19
Mechanical Hazards......................................................................................................136
K.20
Mechanical strength......................................................................................................136
K.21
Construction .................................................................................................................136
K.22
Internal wiring ...............................................................................................................136
K.23
Components.................................................................................................................136
K.24
Supply connection and external flexible cords .................................................................137
K.25
Terminals for external conductors...................................................................................137
K.26
Provision for earthing ....................................................................................................137
K.27
Screws and connections................................................................................................137
K.28
Creepage distances, clearances and distances through insulation....................................137
K.29
Resistance to heat, fire and tracking ...............................................................................139
Annex L (normative) Battery tools and battery packs provided with mains connection or non-
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
isolated sources..............................................................................................................141
L.1
Scope ............................................................................................................................141

<!-- 第 10 页 -->
L.2
Normative References.....................................................................................................141
L.3
Terms and definitions.......................................................................................................141
L.5
General conditions for the tests ........................................................................................142
L.7
Classification ..................................................................................................................142
L.8
Marking and Instructions..................................................................................................142
L.8.12.1.1DV
Modification: Add the following paragraph to Clause L.8.12.1.1:..................143
L.9
Protection against electric shock ......................................................................................143
L.10
Starting.........................................................................................................................144
L.11
Input and current ...........................................................................................................144
L.12
Heating.........................................................................................................................144
L.13
Leakage current ............................................................................................................144
L.14
Moisture resistance .......................................................................................................145
L.15
Electric strength ............................................................................................................145
L.16
Overload protection of transformers and associated circuits..............................................145
L.17
Endurance....................................................................................................................145
L.18
Abnormal operation .......................................................................................................145
L.18.201DV.1
Modification: Replace Item (b) of Clause L.18.201 with the following:..........146
L.18.201DV.2
Modification: Replace Item (c) of Clause L.18.201 with the following:..........146
L.19
Mechanical Hazards .....................................................................................................146
L.20
Mechanical strength ......................................................................................................146
L.21
Construction .................................................................................................................146
L.22
Internal wiring ...............................................................................................................147
L.23
Components .................................................................................................................147
L.24
Supply connection and external flexible cords..................................................................147
L.25
Terminals for external conductors ...................................................................................148
L.26
Provision for earthing.....................................................................................................148
L.28
Creepage distances, clearances and distances through insulation ....................................148
L.29
Resistance to heat, fire and tracking ...............................................................................149
Annex M (normative) Safety of working stands for operation with hand-held motor-operated
electric tools ...................................................................................................................151
M.1
Scope............................................................................................................................151
M.2
Normative references .....................................................................................................151
M.2DV
Modification: Add the following sentence: ...........................................................151
M.3
Terms and Definitions .....................................................................................................151
M.5
General conditions for the tests .......................................................................................151
M.7
Classification .................................................................................................................152
M.8
Marking and instructions .................................................................................................152
M.10
Starting........................................................................................................................153
M.11
Input and current ..........................................................................................................153
M.17
Endurance ...................................................................................................................153
M.19
Mechanical hazards......................................................................................................153
M.21
Construction ................................................................................................................154
M.23
Components ................................................................................................................155
M.24
Supply connection and external flexible cords.................................................................156
M.25
Terminals for external conductors ..................................................................................156
Annex N (normative) Rules for routine tests.................................................................................157
N.1
General..........................................................................................................................157
N.2
Correct operation test......................................................................................................157
N.3
Electric strength test .......................................................................................................157
N.4
Earthing continuity test....................................................................................................158
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Annex DVN
National Difference Deleted .......................................................................158

<!-- 第 11 页 -->
Bibliography.................................................................................................................................159
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 12 页 -->
No Text on This Page
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 13 页 -->
Preface
This is the harmonized CSA Group and UL standard for Hand-Held Motor-Operated Electric Tools – Safety
– Part 1: General Requirements. It is the third edition of CAN/CSA-C22.2 No. 60745-1, and the fourth
edition of UL 60745-1. This harmonized standard has been jointly revised on
iApril 30, 2020. For this
purpose, CSA Group and UL are issuing revision pages dated iApril 30, 2020.
This harmonized standard is based on IEC Publication 60745-1: fourth edition Hand-Held Motor-Operated
Electric Tools – Safety – Part 1: General Requirements, issued April 2006. IEC 60745-1 is copyrighted by
the IEC.
This harmonized standard was prepared by the CSA Group and Underwriters Laboratories Inc. (UL).
This standard is considered suitable for use for conformity assessment within the stated scope of the
standard.
This standard was reviewed by the CSA Subcommittee on Safety of Hand-Held Motor-Operated Electric
Tools, under the jurisdiction of the CSA Technical Committee on Consumer and Commercial Products and
the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally
approved by the CSA Technical Committee. This standard has been developed in compliance with
Standards Council of Canada requirements for National Standards of Canada. It has been published as a
National Standard of Canada by CSA Group.
Application of Standard
Where reference is made to a specific number of samples to be tested, the specified number is to be
considered a minimum quantity.
Note: Although the intended primary application of this standard is stated in its scope, it is important to note that it remains the
responsibility of the users of the standard to judge its suitability for their particular purpose.
Level of harmonization
This standard adopts the IEC text with national differences.
This standard is published as an equivalent standard for CSA Group and UL.
An equivalent standard is a standard that is substantially the same in technical content, except as follows:
Technical national differences are allowed for codes and governmental regulations as well as those
recognized as being in accordance with NAFTA Article 905, for example, because of fundamental climatic,
geographical, technological, or infrastructural factors, scientific justification, or the level of protection that
the country considers appropriate. Presentation is word for word except for editorial changes.
All national differences from the IEC text are included in the CSA Group and UL versions of the standard.
While the technical content is the same in each organization’s version, the format and presentation may
differ.
Interpretations
The interpretation by the standards development organization of an identical or equivalent standard is
based on the literal text to determine compliance with the standard in accordance with the procedural rules
of the standards development organization. If more than one interpretation of the literal text has been
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 14 页 -->
identified, a revision is to be proposed as soon as possible to each of the standards development
organizations to more accurately reflect the intent.
IEC Copyright
For CSA Group, the text, figures, and tables of International Electrotechnical Commission Publication
60745-1 Hand-Held Motor-Operated Electric Tools – Safety – Part 1: General Requirements, copyright
2006, are used in this standard with the consent of the International Electrotechnical Commission. The
IEC Foreword and Introduction are not a part of the requirements of this standard but are included for
information purposes only.
These materials are subject to copyright claims of IEC and UL. No part of this publication may be
reproduced in any form, including an electronic retrieval system, without the prior written permission of UL.
All requests pertaining to the Hand-Held Motor-Operated Electric Tools – Safety – Part 1: General
Requirements UL 60745-1 Standard should be submitted to UL.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 15 页 -->
NATIONAL DIFFERENCES
There are five types of National Differences as noted below. The difference type is noted on the first line of
the National Difference in the standard. The standard may not include all types of these National
Differences.
In the CSA Group and UL publications of this standard, National Differences from the text of International
Electrotechnical Commission (IEC) Publication 60745-1, Safety Requirements for Hand-Held Motor-
Operated Electrical Tools – Safety – Part-1: General Requirements, copyright 2006 are indicated by
notations (differences) and are presented in bold text. The national difference type is included in the body.
DR – These are National Differences based on the national regulatory requirements.
D1 – These are National Differences which are based on basic safety principles and requirements,
elimination of which would compromise safety for consumers and users of products.
D2 – These are National Differences from IEC requirements based on existing safety practices. These
requirements reflect national safety practices, where empirical substantiation (for the IEC or national
requirement) is not available or the text has not been included in the IEC standard.
DC – These are National Differences based on the component standards and will not be deleted until a
particular component standard is harmonized with the IEC component standard.
DE – These are National Differences based on editorial comments or corrections.
Each national difference contains a description of what the national difference entails. Typically one of the
following words is used to explain how the text of the national difference is to be applied to the base IEC
text:
Addition / Add - An addition entails adding a complete new numbered clause, subclause, table,
figure, or annex. Addition is not meant to include adding select words to the base IEC text.
Modification / Modify - A modification is an altering of the existing base IEC text such as the
addition, replacement or deletion of certain words or the replacement of an entire clause,
subclause, table, figure, or annex of the base IEC text.
Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause,
table, figure, or annex without any replacement text.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 16 页 -->
No Text on This Page
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 17 页 -->
FOREWORD
INTERNATIONAL ELECTROTECHNICAL COMMISSION
HAND-HELD MOTOR-OPERATED ELECTRIC TOOLS – SAFETY – Part 1: General requirements
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national
electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions
concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes
International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter
referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in
the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations
liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of
opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that
sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held
responsible for the way in which they are used or for any misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the
maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the
corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be
in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its
technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature
whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or
reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the
correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall
not be held responsible for identifying any or all such patent rights.
International Standard IEC 60745-1 has been prepared by sub-committee 61F: Safety of hand-held motor-
operated electric tools, of IEC technical committee 61: Safety of household and similar electrical
appliances.
This fourth edition cancels and replaces the third edition published in 2001 and its Amendment 1 (2002)
and Amendment 2 (2003). It constitutes a technical revision.
Main changes in this edition include the introduction of requirements for tools with a liquid system,
particularly in Clauses 8, 14 and 21; clarification in Clause 8 on the application of safety warnings;
adaptation of Annex I to the latest version of IEC 61058-1; addition of requirements for electronic circuits in
18.10; introduction of requirements for supports or working stands in Annex M; and information about
routine tests in Annex N.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
The text of this standard is based on the following documents:

<!-- 第 18 页 -->
FDIS
Report on voting
61F/632/FDIS
61F/641/RVD
Full information on the voting for the approval of this standard can be found in the report on voting
indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
A vertical line in the margin shows where this fourth edition has been modified.
This Part 1 is to be used in conjunction with the appropriate part 2, which contains clauses that
supplement or modify the corresponding clauses in Part 1 to provide the relevant requirements for each
type of product.
NOTE 1 In this standard, the following print types are used:
– requirements: in roman type
– test specification: in italic type
– Notes: in smaller roman type
NOTE 2 In Annexes B, K, L and M, subclauses which are additional to those in the main body of the text are numbered starting from
IEC 60745 consists of the following parts, under the general title Hand-held motor-operated electric tools –
Safety:
Part 1: General requirements
Part 2-1: Particular requirements for drills and impact drills
Part 2-2: Particular requirements for screwdrivers and impact wrenches
Part 2-3: Particular requirements for grinders, polishers and disk-type sanders
Part 2-4: Particular requirements for sanders and polishers other than disk type
Part 2-5: Particular requirements for circular saws and circular knives
Part 2-6: Particular requirements for hammers
Part 2-7: Particular requirements for spray guns for non-flammable liquids
Part 2-8: Particular requirements for shears and nibblers
Part 2-9:Particular requirements for tappers
Part 2-11: Particular requirements for reciprocating saws (jig and sabre saws)
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Part 2-12: Particular requirements for concrete vibrators
Part 2-13: Particular requirements for chain saws

<!-- 第 19 页 -->
Part 2-14: Particular requirements for planers
Part 2-15: Particular requirements for hedge trimmers and grass shears
Part 2-16: Particular requirements for tackers
Part 2-17: Particular requirements for routers and trimmers
Part 2-18: Particular requirements for strapping tools
Part 2-19: Particular requirements for jointers
Part 2-20: Particular requirements for band saws
Part 2-21: Particular requirements for drain cleaners
The committee has decided that the contents of this publication will remain unchanged until the
maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in the data related to
the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 20 页 -->
No Text on This Page
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 21 页 -->
INTRODUCTION
Individual countries may wish to consider the application of this Part 1 of IEC 60745, so far as is
reasonable, to tools not mentioned in an individual part 2 and to tools designed on new principles.
If the functions of a tool are covered by the different parts 2 of IEC 60745, the relevant part 2 is applied to
each function separately, so far as is reasonable. If applicable, the influence of one function on the other is
taken into account.
A product employing materials or having forms of construction differing from those detailed in the
requirements of this standard may be examined and tested according to the intention of the requirements
and, if found to be substantially equivalent, may be judged to comply with the standard.
Standards dealing with non-safety aspects of hand-held tools are:
– IEC standards published by TC 59 on methods of measuring performance;
– CISPR 11 and 14 on radio interference suppression;
– IEC 61000-3-2 and IEC 61000-3-3 on electromagnetic compatibility.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 22 页 -->
No Text on This Page
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 23 页 -->
HAND-HELD MOTOR-OPERATED ELECTRIC TOOLS – SAFETY – Part
1: General requirements
Scope
This part of IEC 60745 deals with the safety of hand-held motor-operated or magnetically driven electric
tools, the rated voltage of the tools being not more than 250 V for single-phase a.c. or d.c. tools, and 440 V
for three-phase a.c. tools.
So far as is practicable, this standard deals with the common hazards presented by handheld tools which
are encountered by all persons in the normal use and reasonably foreseeable misuse of the tools.
Tools with an electric heating element are within the scope of this standard. They should also comply with
relevant parts of IEC 60335.
Requirements for motors not isolated from the supply, and having basic insulation not designed for the
rated voltage of the tools, are given in Annex B. Requirements for rechargeable battery-powered motor-
operated or magnetically driven tools and the battery packs for such tools are given in Annex K. Those for
such tools that are also operated and/or charged directly from the mains or a non-isolated source are
given in Annex L.
Hand-held electric tools, hereinafter referred to as tools, which can be mounted on a support or working
stand for use as fixed tools without any alteration of the tool itself, are within the scope of this standard.
Requirements for such supports or working stands are given in Annex M.
This standard does not apply to:
– hand-held tools intended to be used in the presence of explosive atmosphere (dust, vapour or
gas);
– hand-held tools used for preparing and processing food;
– hand-held tools for medical purposes (IEC 60601);
– heating tools which are covered by IEC 60335-2-45.
For hand-held tools intended to be used in vehicles or on board ships or aircraft, additional requirements
may be necessary.
For hand-held tools intended to be used in tropical countries, special requirements may be necessary.
NOTE Attention is drawn to the fact that in many countries, additional requirements are specified by the national health
authorities, the national authorities responsible for the protection of labour, the national water supply authorities, etc.
1DV DR Addition: Add the following paragraph:
This standard deals with tools used in non-hazardous locations in accordance with the
National Electrical Code, NFPA 70, and the Canadian Electric Code, Part 1, CSA C22.1, and
General Requirements – Canadian Electrical Code, Part II, CAN/CSA-C22.2 No. 0.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 24 页 -->
Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
2DV DC Modification: Add the following:
Subclause
from this
standard
Table 1, 21.36
Audio, Video and
Similar Electronic
Apparatus
IEC 60065 Audio,
video and similar
electronic apparatus –
Safety requirements
23.1.5, 23.4,
24.21
Appliance Couplers
IEC 60320 (all parts)
Appliance couplers for
household and similar
general purposes
23.1.5, 23.4,
24.4, 24.21
Attachment Plugs,
Receptacles, and
Connectors
IEC 60309 (all parts)
Plugs, socket-outlets
and couplers for
industrial purposes
IEC 60320 (all parts)
Appliance couplers for
household and similar
general purposes
IEC 60884 (all parts)
Plugs and socket-
outlets for household
and similar purposes
26.4, 26.5
Coatings
ISO 1463 Metallic and
oxide coatings –
Measurement of
coating thickness –
micro-scopical
method
– Metallic and Oxide
– Non-Magnetic
Coatings
ISO 2178 Non-
magnetic coatings on
magnetic substrates –
Measurement of
coating thickness –
Magnetic method
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
DISTRIBUTION WITHOUT PERMISSION FROM UL
Where the IEC or ISO normative documents are referenced in this standard, U. S. and
Canadian standards shall replace the IEC or ISO documents. The following is a matrix that
provides a cross-reference between CSA, UL, IEC, and ISO standards for components. The
standards listed in this table are not necessarily equivalent.
CSA, UL, IEC, and ISO Standards cross reference
Component type
IEC or ISO publication
UL Standard
CSA Standard (C22.2)
UL 60065 Audio, Video
and Similar Electronic
Apparatus – Safety
Requirements
CAN/CSA-C22.2 No.
60065 Audio, video
and similar electronic
apparatus – Safety
requirements
UL 498 Attachment
Plugs and
Receptacles
CSA C22.2 No. 182.3
Special use
attachment plugs,
receptacles, and
connectors
UL 498 Attachment
Plugs and
Receptacles
CSA C22.2 No. 42
General use
receptacles,
attachment plugs, and
similar wiring devices
UL 1682 Plugs,
Receptacles, and
Cable Connectors, of
the Pin and Sleeve
Type
CSA C22.2 No. 182.1
Plugs, receptacles,
and cable connectors
of the pin and sleeve
type
CSA C22.2 No. 182.2
Industrial locking
type, special use
attachment plugs,
receptacles, and
connectors
CSA, UL, IEC, and ISO Standards cross reference Continued on Next Page

<!-- 第 25 页 -->
Subclause
from this
standard
Annex G
Comparative Tracking
Index
IEC 60112 Method for
the determination of
the proof and
comparative tracking
indices of solid
insulating materials
Table 1,
18.10.2, 23.1.2
EMI Filters
IEC 60384-14 Fixed
capacitors for use in
electronic equipment
– Part 14: Sectional
specification: Fixed
capacitors for
electromagnetic
interference
suppression and
connection to the
supply mains
Table 1,
18.10.2, 23.1.2
Capacitors, Double
Protection
IEC 60384-14 Fixed
capacitors for use in
electronic equipment
–.Part 14: Sectional
specification: Fixed
capacitors for radio
interference
suppression and
connection to the
supply mains
20.2
Environmental Testing
– Hammer Tests
IEC 60068-2-75
Environmental testing
– Part 2-75: Tests –
Test Eh: Hammer tests
23.1.3
Flexible Cords and
Cables
IEC 60227 (all parts)
Polyvinyl chloride
insulated cables of
rated voltages up to
and including 450/750
V
IEC 60245 (all parts)
Rubber insulated
cables – rated
voltages up to and
including 450/750 V
8.6, 18.10,
18.10.3
Fuses, Low-Voltage
IEC 60127-3 Miniature
fuses – Part 3: Sub-
miniature fuse-links
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
DISTRIBUTION WITHOUT PERMISSION FROM UL
CSA, UL, IEC, and ISO Standards cross reference Continued
Component type
IEC or ISO publication
UL Standard
CSA Standard (C22.2)
UL 1283
Electromagnetic
Interference Filters
CSA C22.2 No. 8
Electromagnetic
interference (EMI)
filters
CSA E384-14 Fixed
Capacitors for use in
Electronic Equipment
– Part 14: Sectional
Specification: Fixed
Capacitors for
Electromagnetic
Interference
Suppression and
Connection to the
Supply Mains
UL 60384-14 Fixed
Capacitors for Use in
Electronic Equipment
- Part 14: Sectional
Specification: Fixed
Capacitors for
Electromagnetic
Interference
Suppression and
Connection to the
Supply Mains
CSA C22.2, No. 1
Audio, video and
similar electronic
equipment
UL 62 Flexible Cord
and Cables
CSA C22.2 No. 49
Flexible cords and
cables
UL 248 Series
CSA C22.2 No. 248
Series
UL 248-1 Low-Voltage
Fuses – Part 1:
General Requirements
CSA C22.2 No. 248.1
Low-Voltage Fuses –
Part 1: General
Requirements
UL 248-4 Low-Voltage
Fuses – Part 4: Class
CC Fuses
CSA C22.2 No. 248.4
Low-Voltage Fuses –
CSA, UL, IEC, and ISO Standards cross reference Continued on Next Page

<!-- 第 26 页 -->
Subclause
from this
standard
12.2, 15.2
Heater Elements
IEC 60335-1
Household and similar
electrical appliances –
Part 1: General
requirements
7.2, 14.1.2,
21.20
Degrees of Protection
IEC 60529 Degrees of
protection provided by
enclosures (IP Code)
29.2, Annex J
Glow Wire Test
IEC 60695-2-11 Fire
hazard testing – Part
2-11: Glowing/hot-wire
based test methods –
Glow-wire
flammability test
method for end-
products
14.6
Portable Residual
Current Devices
(PRCDs)
IEC 61540 Electrical
accessories – Portable
residual current
devices without
integral overcurrent
protection for
household and similar
use (PRCDs
Ground-Fault Circuit
Interruptors (GFCI)
23.1.3
Lampholders
IEC 60238 Edison
screw lampholders
IEC 60061-1 Lamp
caps and holders
together with gauges
for the control of
interchangeability and
Safety – Part 1: Lamp
Caps
Annex F
Plastics –
Flammability
IEC 60695-11-5 Fire
hazard testing – Part
11-5: Test flames –
Needle flame test
method – Apparatus,
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
DISTRIBUTION WITHOUT PERMISSION FROM UL
CSA, UL, IEC, and ISO Standards cross reference Continued
Component type
IEC or ISO publication
UL Standard
CSA Standard (C22.2)
Part 4: Class CC
Fuses
UL 248-8 Low-Voltage
Fuses – Part 8: Class J
Fuses
CSA C22.2 No. 248.8
Low-Voltage Fuses –
Part 8: Class J Fuses
UL 248-10 Low-Voltage
Fuses – Part 10: Class
L Fuses
CSA C22.2 No. 248.10
Low-Voltage Fuses –
Part 10: Class L Fuses
UL 248-12 Low-Voltage
Fuses – Part 12: Class
R Fuses
CSA C22.2 No. 248.12
Low-Voltage Fuses –
Part 12: Class R Fuses
UL 248-15 Low-Voltage
Fuses – Part 15: Class
T Fuses
CSA C22.2 No. 248.15
Low-Voltage Fuses –
Part 15: Class T Fuses
UL 1030 Sheathed
Heating Elements
CSA C22.2 No. 72
Heater Elements
UL 60335-1 Safety of
Household and Similar
Electrical Appliances
– Part 1: General
Requirements
CAN/CSA-E60335-1/4E
Safety of Household
and Similar Electrical
Appliances – Safety –
Part 1: General
requirements
UL 943 Ground-Fault
Circuit-Interrupters
CSA C22.2 No. 144.1
Ground-fault circuit-
interrupters
UL 496 Lampholders
CSA C22.2 No. 43
Lampholders
UL 1694 Tests for
Flammability of Small
Polymeric Component
Materials
CAN/CSA-C22.2 No.
0.17 Evaluation of
properties of
polymeric materials
CSA, UL, IEC, and ISO Standards cross reference Continued on Next Page

<!-- 第 27 页 -->
Subclause
from this
standard
confirmatory test
arrangement and
guidance
29.2
Plastics –
Flammability
IEC 60695-11-10 Fire
hazard testing Part 11-
10: Test flames – 50 W
Horizontal and vertical
flame test methods
IEC 60695-2-13 Fire
hazard testing – Part
2-13: Glowing/hot-wire
based test methods –
Glow-wire ignitability
test method for
materials
16, 23.1.4, K.2,
K.3.203, L.2,
L.3.203
Power Supplies
IEC 61558-1 Safety of
power transformers,
power supplies,
reactors and similar
products – Part 1:
General requirements
and tests
IEC 61558-2-6 Safety
of power
transformers, power
supply units and
similar – Part 2:
particular
requirements for
safety isolating
transformers for
general use
23.1.10, 23.1.11,
I, Clause 8 in
Annex I,
M.23.1.11
Switches for
Appliances
IEC 61058-1 Switches
for appliances – Part
1: General
requirements
8.10
Symbols
IEC 60417 DB
Graphical symbols for
use on equipment –
Part 1: overview and
application
Table 1, 12.6
Systems of Insulating
Material
IEC 60085 Electrical
insulation – Thermal
classification
26.2
Terminals, Quick
Connect
IEC 60760 Flat, quick-
connect terminations
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
DISTRIBUTION WITHOUT PERMISSION FROM UL
CSA, UL, IEC, and ISO Standards cross reference Continued
Component type
IEC or ISO publication
UL Standard
CSA Standard (C22.2)
UL 1012 Power Units
Other Than Class 2
CSA C22.2 No. 107.1
General use power
supplies
UL 1310 Class 2 Power
Units
CAN/CSA-C22.2 No.
107.2 Battery chargers
CAN/CSA-C22.2 No.
223 Power supplies
with extra-low-voltage
class 2 outputs
UL 61058-1 Switches
for Appliances – Part
1: General
Requirements
CAN/CSA-C22.2 No
61058-1 Switches for
appliances – Part 1:
General requirements
UL 6059 Outline of
Investigation for
Particular
Requirements for
Switches for Tools
T.I.L. A-37 Interim
Certification
Requirements for
Switches Used in
Tools
UL 1446 Systems of
Insulating Materials –
General
CAN/CSA-C22.2 No. 0
General Requirements
– Canadian Electrical
Code, Part II
UL 310 Electrical
Quick-Connect
Terminals
CSA C22.2-No. 153
Quick-connect
terminals
CSA C22.2 No. 0.4
Bonding of Electrical
Equipment
CSA, UL, IEC, and ISO Standards cross reference Continued on Next Page

<!-- 第 28 页 -->
Subclause
from this
standard
31.2
Lasers
IEC 60825-1 Safety of
laser products – Part
1: Equipment
classification,
requirements and
user’s guide
Requirements for
Equipment
Incorporating Lasers
Requirements for
Lasers Contained in
the Applicable
National Codes and
Regulations
25.1, 25.3, 26.2
Wire Connectors and
Soldering Lugs
IEC 60998-2-1
Connecting devices
for low-voltage
circuits for household
and similar purposes –
Part 2-1: Particular
requirements for
connecting devices as
separate entities with
screw-type clamping
units
IEC 60998-2-2
Connecting devices
for low-voltage
circuits for household
and similar purposes –
Part 2-2: Particular
requirements for
connecting devices as
separate entities with
screwless-type
clamping units
IEC 60999-1
Connecting devices –
Electrical copper
Conductors – Safety
requirements for
screw-type and
screwless-type
clamping units – Part
1: General
requirements and
particular
requirements for
clamping units for
conductors from 0,2
mm2 up to 35 mm2
(included)
22.3, 23.1.3
Wires and Cables
IEC 60227 (all parts)
Polyvinyl chloride
insulated cables of
rated voltages up to
and including 450/750
V
IEC 60245 (all parts)
Rubber insulated
cables – rated
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
DISTRIBUTION WITHOUT PERMISSION FROM UL
CSA, UL, IEC, and ISO Standards cross reference Continued
Component type
IEC or ISO publication
UL Standard
CSA Standard (C22.2)
See Note.
CAN/CSA-E60825-1
Safety of laser
products – Part 1:
Equipment
classification,
requirements and
user’s guide
UL 486A-486B Wire
Connectors
CSA C22.2 No. 65 Wire
connectors
UL 44 Thermoset-
Insulated Wires and
Cables
CSA C22.2 No. 38
Thermoset insulated
wires and cables
UL 83 Thermoplastic-
Insulated Wires and
Cables
CSA C22.2 No. 75
Thermoplastic-
insulated wires and
cables
CSA, UL, IEC, and ISO Standards cross reference Continued on Next Page

<!-- 第 29 页 -->
Subclause
from this
standard
8.13DV
Marking and Labeling
Systems
23.1.6
Temperature-
Indicating and
-Regulating
Equipment
IEC 60730-1 Automatic
electrical controls for
household and similar
Use – Part 1: General
requirements
8.13DV
Tests for Rubber
Property – Effect of
Liquids
8.13
Graphical Symbols –
Design Principles
ISO 3864-2 Graphical
symbols – safety
colours and safety
signs – Part 2: Design
principles for product
safety labels
8.1
Graphical Symbols –
Safety Signs
ISO 7010 Graphical
symbols – safety
colours and safety
signs – safety signs
used in workplaces
and public areas
29.2
Plastics –
Flammability
ISO 9772 Cellular
plastics –
Determination of
horizontal burning
characteristics of
small specimens
subjected to a small
flame
IEC 60061-DB1): 2005
Lamp caps and holders together with gauges for the control of interchangeability and safety
IEC 60065: 2001
Audio, video and similar electronic apparatus – Safety requirements
IEC 60068-2-75: 1997
Environmental testing – Part 2: Tests – Test Eh: Hammer tests
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
IEC 60085
Electrical insulation – Thermal classification
DISTRIBUTION WITHOUT PERMISSION FROM UL
CSA, UL, IEC, and ISO Standards cross reference Continued
Component type
IEC or ISO publication
UL Standard
CSA Standard (C22.2)
voltages up to and
including 450/750 V
UL 758 Appliance
Wiring Material
CSA C22.2 No. 127
Equipment and Lead
Wires
CSA-C22.2 No. 210
Appliance wiring
material products
UL 969 Marking and
Labeling Systems
CSA C22.2 No. 0.15
Adhesive labels
UL 60730-1A
Automatic Electrical
Controls for
Household and Similar
Use, Part 1: General
Requirements
CSA C22.2 No. 24
Temperature-
indicating and
-regulating equipment
ANSI/ASTM D 471
Tests for Rubber
Property – Effect of
Liquids
UL 94 Tests for
Flammability of Plastic
Materials for Parts in
Devices and
Appliances
CAN/CSA C22.2 No.
0.17 Evaluation of
properties of
polymeric materials
Note: Additional regulatory requirements apply to equipment incorporating lasers, which are contained in the
applicable national codes and regulations; for example, in Canada, the Radiation Emitting Devices Regulations,
(C.R.C., c. 1370) and in the US, the Code of Federal Regulations (CFR), Title 21, Part 1040.

<!-- 第 30 页 -->
IEC 60112:2003
Method for the determination of the proof and the comparative tracking indices of solid insulating materials
IEC 60127-3
Miniature fuses – Part 3: Sub-miniature fuse-links
IEC 60227 (all parts)
(Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V
IEC 60245 (all parts)
Rubber insulated cables – Rated voltages up to and including 450/750 V
IEC 60309(all parts)
Plugs, socket-outlets and couplers for industrial purposes
IEC 60320(all parts)
Appliance couplers for household and similar general purposes
IEC 60335-1:2001
Safety of household and similar electrical appliances – Part 1: General requirements Amendment 1 (2004)
IEC 60384-14
Fixed capacitors for use in electronic equipment – Part 14: Sectional specification: Fixed capacitors for
electromagnetic interference suppression and connection to the supply mains
IEC 60417-DB3:2002
Graphical symbols for use on equipment
IEC 60529:1989
Degrees of protection provided by enclosures (IP Code) Amendment 1 (1999)4
IEC 60695-2-11
Fire hazard testing – Part 2-11: Glowing/hot-wire based test methods – Glow-wire flammability test method
for end-products
IEC 60695-11-5:2004
Fire hazard testing – Part 11-5: Test flames – Needle-flame test method – Apparatus, confirmatory test
arrangement and guidance
IEC 60695-11-10
Fire hazard testing – Part 11-10: Test flames – 50 W horizontal and vertical flame test methods
IEC 60730-1:1999
Automatic electrical controls for household and similar use – Part 1: General requirements Amendment 1
(2003) 5
IEC 60760
Flat, quick connect terminations
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
IEC 60825-1
Safety of Laser Products – Part 1: Equipment classification, requirements and user’s guide
IEC 60884

<!-- 第 31 页 -->
(all parts) Plugs and socket-outlets for household and similar purposes
IEC 60998-2-1
Connecting devices for low-voltage circuits for household and similar purposes – Part 2-1: Particular
requirements for connecting devices as separate entities with screw-type clamping units
IEC 60998-2-2
Connecting devices for low-voltage circuits for household and similar purposes – Part 2-2: Particular
requirements for connecting devices as separate entities with screwless-type clamping units
IEC 60999-1:1999
Connecting devices – Electrical copper conductors – Safety requirements for screw-type and screwless-
type clamping units – Part 1: General requirements and particular requirements for clamping units for
conductors from 0,2 mm2 up to 35 mm2 (included)
IEC 61058-1:2000
Switches for appliances – Part 1: General requirements Amendment 1 (2001)6
IEC 61540: 1997
Electrical accessories – Portable residual current devices without integral overcurrent protection for
household and similar use (PRCDs) Amendment 1 (1998)7
IEC 61558-1
Safety of power transformers, power supplies, reactors and similar products – Part 1: General
requirements and tests
ISO 1463
Metallic and oxide coatings – Measurement of coating thickness – Microscopical method
ISO 2178
Non-magnetic coatings on magnetic substrates – Measurement of coating thickness – Magnetic method
ISO 3864-2
Graphical symbols – Safety colours and safety signs – Part 2: Design principles for product safety labels
ISO 7010
Graphical symbols – Safety colours and safety signs – Safety signs used in workplaces and public areas
ISO 9772
Cellular plastics – Determination of horizontal burning characteristics of small specimens subjected to a
small flame
1)“DB” refers to the on-line IEC database.
2) A consolidated edition (4.1) exists including IEC 60335-1:2001 and its Amendment 1 (2001).
3)“DB” refers to the on-line IEC database.
4) A consolidated edition (2.1) exists including IEC 60529:1989 and its Amendment 1 (1999).
5) A consolidated edition (3.1) exists including IEC 60730-1:1999 and its Amendment 1 (2003).
6) A consolidated edition (3.1) exists including IEC 61058-1:2000 and its Amendment 1 (2001).
7) A consolidated edition (1.1) exists including IEC 61540:1997 and its Amendment 1 (1998).
Terms and Definitions
For the purposes of this document, the following terms and definitions apply.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Where the terms voltage and current are used, they imply the r.m.s. values, unless otherwise specified.

<!-- 第 32 页 -->
Where in this standard the expressions "with the aid of a tool", "without the aid of a tool", and "requires the
use of a tool", are used, the word "tool" means a hand tool, for example a screwdriver, which may be used
to operate a screw or other fixing means.
3.1
accessible part: part which can be touched by means of the standard test finger in Figure 1,
including, for accessible metal parts, any metal part connected to it
3.2
accessory: device that is attached only to the output mechanism of the tool
3.3
all-pole disconnection: disconnection of all supply conductors except the protective earthing
(grounding) conductor by a single initiating action
3.4
attachment: device attached to the housing or other component of the tool and which may or may
not be attached to the output mechanism and does not modify the normal use of the tool within the scope
of this standard
3.5
basic insulation: insulation, not necessarily including insulation used for functional purposes,
applied to live parts to provide basic protection against electric shock
3.6
class I tool: tool in which protection against electric shock does not rely on basic, double or
reinforced insulation only, but which includes an additional safety precaution in that conductive accessible
parts are connected to the protective earthing conductor in the fixed wiring of the installation in such a way
that conductive accessible parts cannot become live in the event of a failure of the basic insulation. Also
considered as class I tools are tools with double insulation and/or reinforced insulation throughout having
an earthing terminal or earthing contact
3.7
class II tool: tool in which protection against electric shock does not rely on basic insulation only, but
in which additional safety precautions, such as double insulation or reinforced insulation, are provided,
there being no provision for protective earthing or reliance upon installation conditions
3.8
class III tool: tool in which protection against electric shock relies on supply at safety extra-low
voltage, and in which voltages higher than those of safety extra-low voltages are not generated
3.9
class II construction: part of a tool for which protection against electric shock relies upon double
insulation or reinforced insulation
3.10
class III construction: part of a tool for which protection against electric shock relies upon safety
extra-low voltage, and in which voltages higher than those of safety extra-low voltages are not generated
3.11
clearance: shortest distance between two conductive parts, or between a conductive part and the
outer surface of the enclosure, considered as though metal foil were pressed into contact with accessible
surfaces of insulating material, measured through air
NOTE Examples of clearance distances are given in Annex A.
3.12
creepage distance: shortest path between two conductive parts, or between a conductive part and
the outer surface of the enclosure, considered as though metal foil were pressed into contact with
accessible surfaces of insulating material, measured along the surface of the insulating material
NOTE Examples of creepage distances are given in Annex A.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
3.13
detachable cord: flexible cord, for supply, intended to be connected to the tool by means of a
suitable appliance coupler

<!-- 第 33 页 -->
3.14
detachable part: part which can be removed or opened without the aid of a tool, or a part which is
removed in accordance with the instruction for use, except user maintenance items, even if removal
requires the use of a tool
3.15
double insulation: insulation system comprising both basic insulation and supplementary
insulation
3.16
electronic circuit: circuit incorporating at least one electronic component
3.17
electronic component: part in which conduction is achieved principally by electrons moving
through a vacuum, gas or semiconductor, with the exclusion of neon indicators
3.18
manufacturer's service organization only
3.19
extra-low voltage: voltage supplied from a source within the tool and, which, when the tool is
supplied at rated voltage, does not exceed 50 V between conductors and between conductors and earth
3.20
extra-severe duty conditions of insulating material: where there is heavy deposition of
conductive material and a long period of electrical stress; or an extra heavy deposition of conductive
material and a short period of electrical stress
3.21
hand-held tool (in this standard abbreviated to "tool"): electric motor-operated or magnetically-
driven machine intended to do mechanical work, with or without provisions for mounting on a support, and
so designed that the motor and the machine form an assembly which can easily be brought to the place of
operation, and which is either held or supported by hand or suspended during operation
NOTE Hand-held tools may be provided with a flexible shaft, the motor being either fixed or portable.
3.22
intermittent operation: operation in a series of specified identical cycles, each cycle being
composed of a period of operation under normal load followed by a rest period with the tool running idle or
switched off
3.23
liquid system: system that employs water or a water-based liquid from an external or integral
supply that is necessary to complete the intended function of the tool
3.24
live part: any conductor or conductive part intended to be energized in normal use, including a
neutral conductor but, by convention, not a PEN conductor
3.25
no-load input/current: highest input or current obtained when a tool is operated at rated voltage
manufacturer and adjusted according to manufacturer's instructions, ready for use
3.26
non-detachable part: part which can only be removed or opened with the aid of a tool, or a part
which fulfils the test of 21.22
3.27
non-self-resetting thermal cut-out: thermal cut-out which requires a manual operation for
resetting, or replacement of a part, in order to restore the current
3.28
normal duty conditions of insulating material: where there is virtually no deposition of
conductive material and a long period of electrical stress; or a light deposition of conductive material and a
short period of electrical stress
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 34 页 -->
3.29
normal load: load to be applied to a tool at rated voltage or at the upper limit of the rated voltage
range, to obtain rated input or rated current, any marking of short-time or intermittent operation being
observed and, unless otherwise specified, heating elements, if any, being operated as in normal use
3.30
normal use: use of a tool for which it is designed, taking into account the manufacturer's
instructions
3.31
protective device: device the operation of which prevents a hazardous situation under abnormal
operation conditions
3.32
protective impedance: impedance connected between live parts and accessible conductive parts,
and of value so that the current is limited to a safe value
3.33
rated current: current assigned to the tool by the manufacturer. If no current rating is assigned to
the tool, the rated current for the purpose of this standard is the current measured when the tool is
operated under normal load
3.34
rated frequency: frequency assigned to the tool by the manufacturer
3.35
rated frequency range: frequency range assigned to the tool by the manufacturer, expressed by
its lower and upper limits
3.36
rated input: input in watts assigned to the tool by the manufacturer. If no input is assigned to the
tool, the rated input for the purpose of this standard is the input measured when the tool is operated under
normal load
3.37
lower and upper limits
3.38
rated no-load speed: no-load speed at rated voltage or at the upper limit of the rated voltage range
assigned to the tool by the manufacturer
3.39
rated operating time: operating time assigned to the tool by the manufacturer
3.40
rated voltage: voltage assigned to the tool by the manufacturer. For three-phase supply, it is the
voltage between phases
3.41
lower and upper limits
3.42
reinforced insulation: insulation of hazardous live parts which provides a degree of protection
against electric shock equivalent to double insulation
NOTE Examples of reinforced insulation are a single layer or several layers which cannot be tested singly as basic
insulation or supplementary insulation.
3.43
residual current device (RCD): device intended to detect a diversion of current from a circuit in a
way that may expose the user to an electric shock; in such conditions the device opens the circuit
NOTE Such a device is also known as portable residual current device (PRCD), ground fault circuit interrupter (GFCI) or
earth leakage circuit breaker (ELCB)
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
3.44
instruction manual and performed by authorized service centre

<!-- 第 35 页 -->
3.45
safety extra-low voltage: rated voltage not exceeding 42 V between conductors and between
conductors and earth, the no-load voltage not exceeding 50 V. When safety extra-low voltage is obtained
from the supply mains, it is to be through a safety isolating transformer or a convertor with separate
windings, the insulation of which complies with double or reinforced insulation requirements
3.46
safety isolating transformer: transformer, the input winding of which is electrically separated from
the output winding by an insulation at least equivalent to double insulation or reinforced insulation, and
which is intended to supply a distribution circuit, a tool or other equipment at safety extra-low voltage
3.47
self-resetting thermal cut-out: thermal cut-out which automatically restores the current after the
relevant part of the tool has cooled down to a given value
3.48
severe duty conditions of insulating material: where there is a light deposition of conductive
material and a long period of electrical stress; or a heavy deposition of conductive material and a short
period of electrical stress
3.49
short-time operation: operation under normal load for a specified period, starting from cold, the
intervals between each period of operation being sufficient to allow the tool to cool down approximately to
ambient temperature
3.50
supplementary insulation: independent insulation applied in addition to the basic insulation, in
order to provide protection against electric shock in the event of a failure of the basic insulation
3.51
supply cord: flexible cord, for supply purposes, which is fixed to the tool
3.52
temperature limiter: temperature-sensing device, the operating temperature of which may be
either fixed or adjustable, and which, during normal operation, operates by opening or closing a circuit
when the temperature of the controlled part reaches a predetermined value. It does not make the reverse
operation during the normal duty cycle of the tool
3.53
thermal cut-out: device which, during abnormal operation, limits the temperature of the controlled
part by automatically opening the circuit, or by reducing the current, and which is so constructed that its
setting cannot be altered by the user
3.54
thermal link: thermal cut-out which operates only once, and then requires partial or complete
replacement
3.55
thermostat: temperature-sensing device, the operating temperature of which may be either fixed or
adjustable; and which, during normal operation, keeps the temperature of the controlled part between
certain limits by automatically opening and closing a circuit
3.56
type X attachment: method of attachment of the supply cord so that it can easily be replaced
3.57
type Y attachment: method of attachment of the supply cord such that any replacement is intended
to be made by the manufacturer, its service agent or similar qualified person
3.57DV D2 Modification: Add the following to the end of the definition:
as recommended in the instruction manual
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
3.58
type Z attachment: method of attachment of the supply cord so that it cannot be replaced without
breaking or destroying the tool

<!-- 第 36 页 -->
3.59
user maintenance: any maintenance operation stated in the instructions for use or marked on the
tool which the manufacturer of the tool intends the user to perform
3.60
working voltage: maximum voltage, without the effect of transient voltages, to which the part under
consideration is subjected when the tool is supplied at its rated voltage and operating under normal load
General requirements
Tools shall be so constructed that in normal use they function safely so as to cause no danger to persons
or surroundings, even in the event of reasonably foreseeable misuse.
In general, this principle is achieved by fulfilling the relevant requirements specified in this standard, and
compliance is checked by carrying out all the relevant tests.
NOTE Annex N shows an example of routine tests.
General conditions for the tests
5.1
Tests according to this standard are type tests.
5.2
Unless otherwise specified, the tests are made on a single tool, which shall withstand all the relevant
tests. However, any test that requires tool modifications or disassembly after the test may be performed on
a separate sample.
Additional samples may be required, for example, if the tool is designed for different supply voltages. The
testing of components may necessitate the submission of additional samples of these components.
The cumulative stress resulting from successive tests on electronic circuits is to be avoided. It may be
necessary to replace components or to use additional samples. The number of additional samples should
be kept to a minimum by an evaluation of the relevant electronic circuits.
5.3
Unless otherwise specified, the tests are carried out in the order of the clauses. If it is evident from
the construction of the tool that a particular test is not applicable, the test is not made.
5.4
The tests are carried out with the tool, or any movable part of it, placed in the most unfavourable
position that may occur in normal use.
5.5
Tools provided with controls or switching devices are tested with these controls or devices adjusted
to their most unfavourable settings, if the setting can be altered by the user. Electronic speed control
devices are set for the highest speed.
If the adjusting means of the control is accessible without the aid of a tool, this subclause applies whether
the setting can be altered by hand or with the aid of a tool. If the adjusting means is not accessible without
the aid of a tool, and if the setting is not intended to be altered by the user, this subclause does not apply.
Adequate sealing is regarded as preventing alteration of the setting by the user.
5.6
The tests are made in a draught-free location and, in general, at an ambient temperature of
(20 ± 5) °C.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
temperature, the room temperature is, in case of doubt, maintained at (23 ±2) °C.

<!-- 第 37 页 -->
5.7.1
Tools for a.c. only are tested with a.c. at rated frequency, if marked, and those for a.c./d.c. are
tested at the more unfavourable supply.
Tools for a.c. which are not marked with rated frequency, or marked with a frequency range of 50 Hz to 60
Hz, are tested with either 50 Hz or 60 Hz, whichever is the more unfavourable.
5.7.2
Tools having more than one rated voltage are tested on the basis of the most unfavourable voltage.
When it is specified for tools marked with a rated voltage range that the supply voltage is equal to the rated
voltage multiplied by a factor, the supply voltage is equal to:
– the upper limit of the rated voltage range multiplied by this factor, if greater than 1;
– the lower limit of the rated voltage range multiplied by this factor, if smaller than 1.
When a factor is not specified, the supply voltage is the most unfavourable within the rated voltage range.
For tools having more than one rated voltage or rated voltage range, it may be necessary to make some of
the tests at the minimum, the mean, and the maximum values of the rated voltage, or the rated voltage
range, in order to establish the most unfavourable voltage.
5.7.3
For tools marked with a rated voltage range and rated input corresponding to the mean of the rated
voltage range, when it is specified that the power input is equal to rated input multiplied by a factor, the
input is equal to:
factor, if greater than 1:
factor, if smaller than 1.
When a factor is not specified, the input corresponds to the input at the most unfavourable rated voltage
within the range.
5.8
When alternative attachments are made available for the tool by its manufacturer, the tool is tested
with those attachments which give the most unfavourable results.
5.9
Unless otherwise specified, tools are tested with the appropriate flexible cord connected to the tool.
5.10
If class I tools have accessible metal parts which are not connected to an earthing terminal or
earthing contact, and are not separated from live parts by an intermediate metal part which is connected to
an earthing terminal or earthing contact, such parts are checked for compliance with the appropriate
requirements specified for class II construction.
If class I tools have accessible non-metallic parts, such parts are checked for compliance with the
appropriate requirements specified for class II construction, unless these parts are separated from live
parts by an intermediate metal part connected to an earthing terminal or earthing contact.
5.11
If class I or class II tools have parts operating at safety extra-low voltage, such parts are checked for
compliance with the appropriate requirements specified for class III tools.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
5.12
When testing electronic circuits, the supply is to be free from those perturbations from external
sources that can influence the results of the tests.

<!-- 第 38 页 -->
5.13
If, in normal use, the heating element cannot be operated unless the motor is running, the element
is tested with the motor running. If the heating element can be operated without the motor running, the
element is tested with or without the motor running, whichever is the more unfavourable. Heating elements
incorporated in the tool are connected to a separate supply unless otherwise specified.
5.14
For attachments performing a function which is within the scope of one of the relevant parts 2, the
tests are made in accordance with that part 2.
For other attachments, the tests are made in accordance with manufacturer's instructions; in the absence
of such instructions, the tool is operated continuously at a load at which rated input or rated current is
attained.
5.15
If a torque is to be applied, the method of loading is chosen so as to avoid additional stresses, such
as those caused by side thrust. Additional loads necessary for the correct operation of the tool are,
however, taken into consideration.
If a brake is used for applying a load, it must be applied gradually to assure that the starting current does
not affect the test. Modification of output means for purpose of loading is permitted for the connection to a
brake.
5.16
Tools intended to be operated at safety extra-low voltage are tested together with their supply
transformer, if this is normally sold with the tool.
Void
Classification
7.1
Tools shall be of one of the following classes with respect to protection against electric shock:
class I, class II, class III.
Compliance is checked by inspection and by the relevant tests.
7.2
Tools shall have the appropriate degree of protection against harmful ingress of water according to
IEC 60529. If a degree other than IPX0 is required this shall be specified in the part 2.
Compliance is checked by inspection and by the relevant tests.
Marking and instructions
8.1
Tools shall be marked with:
– rated voltage(s) or rated voltage range(s), in volts. Tools for star-delta connection shall be clearly
marked with the two rated voltages (for example 230 Δ/ 400 Y);
– symbol for nature of supply, unless the rated frequency is marked. The symbol for nature of
supply shall be placed next to the marking for rated voltage;
– rated input, in watts or rated current, in amperes. The rated input or current to be marked on the
tool is the total maximum input or current that can be on circuit at the same time. If a tool has
alternative components which can be selected by a control device, the rated input or rated current
is that corresponding to the highest loading possible;
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 39 页 -->
– name or trade mark or identification mark and address of the manufacturer or any other agent
responsible for placing the tool on the market;
– model or type reference;
– symbol for class II construction, for class II tools only;
– IP number according to degree of protection against ingress of water other than IPX0. If the first
numeral for the IP numbering is omitted, the omitted numeral shall be replaced by the letter X, for
example IPX5;
– “WARNING – To reduce the risk of injury, user must read instruction manual” or the sign M002 of
ISO 70108.
If used, the word “WARNING” shall be in capital letters not less than 2,4 mm high and shall not be
separated from the cautionary statement.
If used, the statement shall be verbatim except the term “operator’s manual” or “user guide” may be
used for the term “instruction manual”.
Additional markings are allowed, provided they do not give rise to misunderstanding.
Compliance is checked by inspection.
8 The future safety sign M002 is currently in DIS stage as ISO 7010:2003/DAmd4.
8.1DV D1 Modification: Add the following:
– date of manufacture.
The date of manufacture may be a dating period not exceeding any one month. The date of
manufacture may be abbreviated or in an established, accepted code or a code affirmed by
the manufacturer.
8.1DV.1 D1 Addition: Add the following clause:
If a nameplate carries a required marking and is on a part that must be removed for normal
servicing of the tool, the construction shall be such that the nameplate shall be returned to
its proper location for the tool to be operable.
A cautionary marking shall be permanent and shall be located on a part permanently
attached to the tool or on a part that cannot be removed without impairing the operation or
the appearance of the tool.
A fold-over label attached to the power supply cord is acceptable.
Cautionary markings shall be used verbatim as stated. Optional cautionary statements may
be added to the markings, as deemed necessary, by the manufacturer. Cautionary
statements having the same signal word may be combined into one paragraph under one
signal word. The order of statements shall be markings required by Part 1, markings
required by the applicable Part 2, and any optional markings.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 40 页 -->
In cases where the words "danger", "warning", and "caution" appear together, the
cautionary markings shall be in the order of severity, i.e., " danger, warning, and caution".
8.1DV.2 D1 Modification: Add the following paragraph:
Markings in accordance with the marking clause of the latest edition of the product
standard may be used.
8.2
Tools for short-time operation or intermittent operation shall be marked with rated operating time, or
construction of the tool.
The marking of short-time operation or intermittent operation shall correspond to normal use.
The marking of intermittent operation shall be such that the rated operating time precedes the rated resting
time, both markings being separated by an oblique stroke.
Compliance is checked by inspection.
8.3
The marking of tools intended to be operated without adjustment in a rated range of values (voltage,
frequency, etc.) shall be differentiated from those intended to be operated with or without adjustment under
different values of the same criteria (voltage, frequency, etc.).
The lower and upper limits of the rated range of values shall be separated by a hyphen (-).
The different rated values shall be separated by an oblique stroke (/).
Examples:
115-230 V: The tool is suitable for any value within the marked range.
115/230 V: The tool is only suitable for the marked values.
Compliance is checked by inspection.
8.4
If the tool can be adjusted to suit different rated voltages, the voltage to which the tool is adjusted
shall be clearly discernible.
This requirement does not apply to tools for star-delta connection.
For tools where frequent changes in voltage setting are not required, this requirement is considered to be
met if the rated voltage to which the tool is adjusted can be determined from a wiring diagram fixed to the
tool. The wiring diagram may be on the inside of a cover which has to be removed to connect the supply
conductors. It is not to be on a label loosely attached to the tool.
Compliance is checked by inspection.
8.5
For tools marked with more than one rated voltage or with more than one rated voltage range, the
rated power input for each of these voltages or ranges shall be marked.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 41 页 -->
The upper and lower limits of the rated power input shall be marked on the tool so that the relation
between input and voltage appears distinctly, unless the difference between the limits of a rated voltage
range does not exceed 10% of the mean value of the range, in which case the marking for rated power
input may be related to the mean value of the range.
Compliance is checked by inspection.
8.6
If units or technical data are expressed by symbols, the following symbols shall be used:
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 42 页 -->
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 43 页 -->
The dimensions for the symbol for class II tools shall be such that the length of the sides of the outer
square is about twice the length of the sides of the inner square. The length of the sides of the outer
square shall not be less than 5 mm, unless the largest dimension of the tool does not exceed 15 cm, in
which case the dimensions of the symbol may be reduced, but the length of the sides of the outer square
shall not be less than 3 mm.
The symbol for class II tools shall be so placed that it will be obvious that it is a part of the technical
information, and is unlikely to be confused with any other marking.
When other units are used, the units and their symbols shall be those of the international standardized
system.
Additional symbols other than international symbols are allowed, provided they do not give rise to
misunderstanding.
Compliance is checked by inspection and measurement.
8.7
Tools to be connected to more than two supply conductors shall be provided with a connection
diagram, fixed to the tool, unless the correct mode of connection is obvious.
The correct mode of connection is deemed to be obvious if the terminals for the supply conductors are
indicated by arrows pointing towards the terminals. The earthing conductor is not a supply conductor. For
tools for star-delta connection, the wiring diagram should show how the windings are to be connected.
Compliance is checked by inspection.
8.8
Except for type Z attachments, terminals shall be indicated as follows:
– Terminals intended exclusively for the neutral conductor shall be indicated by the letter N.
– Earthing terminals shall be indicated by the symbol
These indications shall not be placed on screws, removable washers or other parts which might be
removed when conductors are being connected.
Compliance is checked by inspection.
8.9
Unless it is obviously unnecessary, switches which may give rise to a hazard when operated shall be
marked, or so placed as to indicate clearly which part of the tool they control.
Indications used for this purpose shall, wherever practicable, be comprehensible without a knowledge of
languages, national standards, etc.
Compliance is checked by inspection.
8.10
For tools which might cause danger when started unexpectedly, the "off" position of the mains
switch shall be indicated, unless this position is obvious; the indication, if required, shall be the figure O, as
given by symbol IEC 60417-5008 (DB:2002-10).
The figure O shall not be used for any other indication.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 44 页 -->
The position of the moving contacts of the mains switch shall correspond to the indications for the different
positions of its operating means.
NOTE The figure O may, for example, also be used on a digital programming keyboard.
Compliance is checked by inspection.
8.11
Regulating devices and the like, intended to be adjusted during operation, shall be provided with an
indication for the direction of adjustment to increase or to decrease the value of the characteristic being
adjusted. An indication of + and - is considered to be sufficient.
The requirement does not apply to regulating devices provided with an adjusting means, if its fully "on"
position is opposite to its "off" position.
If figures are used for indicating the different positions, the "off" position shall be indicated by the figure O
and the other position shall be indicated by figures reflecting the greater output, input, speed, etc.
The indication for the different positions of the operating means of a control device need not to be placed
on the device itself.
Compliance is checked by inspection.
8.12
An instruction manual and safety instructions shall be provided with the tool and packaged in such a
way that is noticed by the user when the tool is removed from the packaging. The safety instructions may
be separate from the instruction manual. An explanation of the symbols required by this standard shall be
provided in either the instruction manual or the safety instructions.
They shall be written in the official language(s) of the country in which the tool is sold.
They shall be legible and contrast with the background.
They shall include the name and address of the manufacturer or supplier or any other agent responsible
for placing the tool on the market.
8.12.1
The subjects of safety instructions are the General Power Tool Safety Warnings of Part 1 as given
in 8.12.1.1, the specific tool Safety Warnings of the relevant part 2 and any additional safety warning
statements deemed necessary by the manufacturer. The General Power Tool Safety Warnings and the
specific tool Safety Warnings, if in English, shall be verbatim and in any other official language to be
equivalent.
Format of all Safety Warnings must differentiate, by font highlighting or similar means, the context of
clauses as illustrated below.
All notes in the safety instructions are not to be printed, they are information for the designer of the
manual.
8.12.1DV D1 Modification: Add the following paragraph:
An instruction manual in accordance with the instructions clause of the latest edition of the
product standard may be used.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 45 页 -->
8.12.1DV.1 D2 Modification: Add the following paragraph to Clause 8.12.1:
Clauses 8.12.1.1, 8.12.1.2, 8.12.2 (first paragraph and associated warnings only) may be
replaced in their entirety with Clauses 8.14.1.1, 8.14.1.2, and 8.14.1.3 of UL 62841-1 or
CAN/CSA C22.2 No. 62841-1. Partial substitution of the above-mentioned set of clauses
between standards is not permitted.
8.12.1.1
General Power Tool Safety Warnings
WARNING Read all safety warnings and all instructions. Failure to follow the warnings and
instructions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
The term "power tool" in the warnings refers to your mains-operated (corded) power tool or battery-
operated (cordless) power tool.
1) Work area safety
a) Keep work area clean and well lit. Cluttered or dark areas invite accidents.
b) Do not operate power tools in explosive atmospheres, such as in the presence of
flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or
fumes.
c) Keep children and bystanders away while operating a power tool. Distractions can
cause you to lose control.
2) Electrical safety
a) Power tool plugs must match the outlet. Never modify the plug in any way. Do not
use any adapter plugs with earthed (grounded) power tools. Unmodified plugs and
matching outlets will reduce risk of electric shock.
b) Avoid body contact with earthed or grounded surfaces such as pipes, radiators,
ranges and refrigerators. There is an increased risk of electric shock if your body is
earthed or grounded.
c) Do not expose power tools to rain or wet conditions. Water entering a power tool will
increase the risk of electric shock.
d) Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the
power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or
entangled cords increase the risk of electric shock.
e) When operating a power tool outdoors, use an extension cord suitable for outdoor
use. Use of a cord suitable for outdoor use reduces the risk of electric shock.
f) If operating a power tool in a damp location is unavoidable, use a residual current
device (RCD) protected supply. Use of an RCD reduces the risk of electric shock.
NOTE The term "residual current device (RCD)" may be replaced by the term "ground fault circuit
interrupter (GFCI)" or "earth leakage circuit breaker (ELCB)".
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 46 页 -->
3) Personal safety
a) Stay alert, watch what you are doing and use common sense when operating a
power tool. Do not use a power tool while you are tired or under the influence of
drugs, alcohol or medication. A moment of inattention while operating power tools may
result in serious personal injury.
b) Use personal protective equipment. Always wear eye protection. Protective
equipment such as dust mask, non-skid safety shoes, hard hat, or hearing protection used
for appropriate conditions will reduce personal injuries.
c) Prevent unintentional starting. Ensure the switch is in the off-position before
connecting to power source and/or battery pack, picking up or carrying the tool.
Carrying power tools with your finger on the switch or energising power tools that have the
switch on invites accidents.
d) Remove any adjusting key or wrench before turning the power tool on. A wrench or
a key left attached to a rotating part of the power tool may result in personal injury.
e) Do not overreach. Keep proper footing and balance at all times. This enables better
control of the power tool in unexpected situations.
f) Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing
and gloves away from moving parts. Loose clothes, jewellery or long hair can be caught
in moving parts.
g) If devices are provided for the connection of dust extraction and collection
facilities, ensure these are connected and properly used. Use of dust collection can
reduce dust-related hazards.
4) Power tool use and care
a) Do not force the power tool. Use the correct power tool for your application. The
correct power tool will do the job better and safer at the rate for which it was designed.
b) Do not use the power tool if the switch does not turn it on and off. Any power tool
that cannot be controlled with the switch is dangerous and must be repaired.
c) Disconnect the plug from the power source and/or the battery pack from the power
tool before making any adjustments, changing accessories, or storing power tools.
Such preventive safety measures reduce the risk of starting the power tool accidentally.
d) Store idle power tools out of the reach of children and do not allow persons
unfamiliar with the power tool or these instructions to operate the power tool. Power
tools are dangerous in the hands of untrained users.
e) Maintain power tools. Check for misalignment or binding of moving parts,
breakage of parts and any other condition that may affect the power tool's operation.
If damaged, have the power tool repaired before use. Many accidents are caused by
poorly maintained power tools.
f) Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting
edges are less likely to bind and are easier to control.
g) Use the power tool, accessories and tool bits etc. in accordance with these
instructions, taking into account the working conditions and the work to be
performed. Use of the power tool for operations different from those intended could result
in a hazardous situation.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 47 页 -->
5) Service
a) Have your power tool serviced by a qualified repair person using only identical
replacement parts. This will ensure that the safety of the power tool is maintained.
8.12.1.2
The order of the Safety Instructions shall be either in accordance with either item A) or B) and in
accordance with item C):
A) The Part 1 warnings are followed by the relevant part 2 warnings. The order of the warnings
within the Part 1 and the part 2 warnings shall remain as given above and in the relevant part 2.
B) The Part 1 and the part 2 warnings may be divided into the sections defined by the numbered
subtitles and the associated warnings below the numbered subtitle. The order of warnings within
each section shall remain as given above and in the relevant part 2.
When warnings are presented in this manner, the title of the Part 1 “General Power Tool Safety
Warnings” shall be omitted and the 1st sentence of the warnings in 8.12.1.1 and 8.12.2, if
applicable, shall be modified as follows:
WARNING Read all safety warnings designated by the symbol
and all
instructions.
The sections of the safety warnings shall be presented in the related topic of the Instruction
Manual.
The Instruction Manual section titles for part 1 warnings shall have a format:
General Power Tool Safety Warnings – [Section subtitle]
Example:
General Power Tool Safety Warnings – Personal Safety
The Instruction Manual section titles for part 2 warnings shall have a format:
[Tool category name] Safety Warnings – [Section subtitle]
Example:
Circular Saw Safety Warnings – Cutting Procedures
particular part 2 shall be presented in the given order and the formatting rule above shall be
followed without the [Section subtitle].
C) Any additional warnings deemed necessary by the manufacturer, shall not be inserted within
any of the part 1 or part 2 warnings. They may be either appended to the section(s) of the Part 1 or
part 2 in accordance with the topic of the safety warnings or located in any other part of the
instruction manual.
8.12.2
If the Safety Instructions are separate from the Instruction Manual, then the following warnings
shall be included in the Instruction Manual. These warnings, if in English, shall be verbatim and in any
other official language to be equivalent.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
WARNING Read all safety warnings and all instructions. Failure to follow the
warnings and instructions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.

<!-- 第 48 页 -->
The Instruction Manual shall be provided with the following information, if appropriate.
a) Instructions for putting into use
1) Setting-up or fixing power tool in a stable position as appropriate for power tools which
can be mounted on a support
2) Assembly
3) Connection to power supply, cabling, fusing, socket type and earthing requirements
4) Illustrated description of functions
5) Limitations on ambient conditions
6) List of contents
b) Operating instructions
1) Setting and testing
2) Tool changing
3) Clamping of work
4) Limits on size of workpiece
5) General instructions for use
c) Maintenance and servicing
1) Regular cleaning, maintenance, method for keeping tools sharp, and lubrication
2) Servicing by manufacturer or agent; list of addresses
3) List of user-replaceable parts
4) Special tools which may be required
5) For power tools with type X attachment, where a specially prepared cord is needed to
specially prepared cord available through the service organization.
6) For power tools with type Y attachment: if the replacement of the supply cord is
necessary, this has to be done by the manufacturer or his agent in order to avoid a safety
hazard.
7) For power tools with type Z attachment: the supply cord of this power tool cannot be
replaced, and the power tool shall be scrapped.
d) For tools with a liquid system, the substance of the following, as appropriate:
1) Instructions for
– the connection to the liquid supply;
– the use of the liquid and the use of attachments to comply with 14.4 in order to
avoid affection of the tool by liquid;
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
– the inspection of hoses and other critical parts which could deteriorate;

<!-- 第 49 页 -->
– the maximum permitted pressure of the liquid supply
2) For tools provided with an RCD
– warning and instruction never to use the tool without the RCD provided with the
tool;
– warning and instruction always to test the correct operation of the RCD before
starting work, unless the RCD is of a self-checking type
3) For tools for use in combination with an isolating transformer: warning and instruction
never to use the tool without the transformer delivered with the tool or of the type as
specified in these instructions
4) Warning and instruction that replacement of the plug or the supply cord shall always be
carried out by the manufacturer of the tool or his service organization
5) Warning and instruction to keep liquid clear off the parts of the tool and away from
persons in the working area.
8.13
Markings required by the standard shall be easily legible and durable. Signs shall be in contrast
such as colour, texture, or relief, to their background such that the information or instructions provided by
the signs are clearly legible when viewed by the naked eye from a distance of not less than 500 mm. Signs
need not be in accordance with the blue colour requirements of ISO 3864-2.
Compliance is checked by inspection and by rubbing the marking by hand for 15 s with a piece of cloth
soaked with water and again for 15 s with a piece of cloth soaked with petroleum spirit.
After all the tests of this standard, the marking shall be easily legible, it shall not be easily possible to
remove marking plates, and they shall show no curling.
In considering the durability of the marking, the effect of normal use is taken into account. Thus, for
example, marking by means of paint or enamel other than vitreous enamel on containers that are likely to
be cleaned frequently is not considered to be durable.
The petroleum spirit to be used for the test is aliphatic solvent hexane having a maximum aromatics
content of 0,1% by volume, a kauributanol value of 29, an initial boiling point of approximately 65 °C, a dry
point of approximately 69 °C and a specific mass of approximately 0,689 kg/l.
8.13DV D1 Modification: Add the following:
Additional tests are required for adhesive labels to test the durability of the adhesive
system.
Compliance is checked by inspection and, if the label is not in compliance with CSA C22.2
No. 0.15 and UL 969, the tests described in this clause shall be performed.
After being subjected to the conditions described below, a pressure-sensitive label or a
label secured by cement or adhesive shall be considered to be of a permanent nature if
immediately following removal from each test medium and after being exposed to room
temperature for 24 hours following removal from each medium:
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
a) each sample demonstrates good adhesion and the edges are not curled.

<!-- 第 50 页 -->
b) the label resists defacement or removal as demonstrated by scraping across the
test panel with a flat steel blade, held at right angles to the test panel. The blade is to
be 0,8 mm thick and of any convenient width.
c) The printing is legible and is not defaced by rubbing with thumb or finger
pressure.
Label Heating Test
Three samples of the label applied to test surfaces as in the intended application shall be
placed for 240 h in an oven maintained at the temperature specified in Table 8.13DV.
Table 8.13DV
Maximum surface temperatures
Maximum temperature during temperature test of
surface to which applied
Oven temperature
°C
°C
60 or less
80 or less
100 or less
125 or less
150 or less
a
Over 150
a A label that is applied to a surface attaining a temperature greater than 150°C during the temperature test shall
be heated at a temperature representative of the temperatures attained by the appliance during intended use
and abnormal use.
Label Immersion Tests
Six samples of the labels applied to test surfaces as in the intended application shall be
placed in a controlled atmosphere maintained at 23.0 ±2.0° C with a 50 ±5 % relative
humidity for 24 h. Three samples shall then be immersed in water and three samples
immersed in ASTM reference oil No. 3 at a temperature of 21.0 ±2.0°C for 48 h in each case.
Note: The properties of ASTM reference oil No. 3 are defined in ANSI/ASTM D471.
Label Standard Atmosphere Test
Three samples of the label applied to test surfaces as in the intended application shall be
placed for 72 hours in a controlled atmosphere maintained at 23.0 ±2.0°C with a 50 ±5 %
relative humidity.
After all the tests of this standard, the marking shall be easily legible; it shall not be easily
possible to remove marking plates and they shall show no curling.
8.13DV.1 D1 Modification: Add the following subclause:
A reagent grade hexane containing a minimum of 85% n-hexane may be used as an
alternative petroleum spirit for the test in Clause 8.13.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 51 页 -->
NOTE The designation "n-hexane" is the chemical nomenclature for a "normal" or straight chain
hydrocarbon. An example of this petroleum spirit is also known as a certified ACS (American Chemical
Society) reagent grade hexane (CAS #110-54-3).
8.14
Markings specified in 8.1 to 8.5 shall be on a main part of the tool. Markings specified in 8.1, 8.2, 8.3
and 8.5 shall be placed together.
Markings on the tool shall be clearly discernible from the outside of the tool, but after removal of a cover, if
necessary. It shall be possible to remove or open this cover without the aid of a tool.
Indications for switches and controls shall be placed on or in the vicinity of these components; they shall
not be placed on parts which can be repositioned, or positioned in such a way that the marking is
misleading.
Compliance is checked by inspection.
8.15
If compliance with this standard depends upon the operation of a replaceable thermal link or fuse-
link, the reference number or other means for identifying the link shall be marked on the link, or in a place
that it is clearly visible after the link has failed, when the tool has been dismantled to the extent necessary
for replacing the link.
This requirement does not apply to links which can only be replaced together with a part of the tool.
Compliance is checked by inspection.
Protection against access to live parts
Tools shall be so constructed and enclosed that there is adequate protection against accidental contact
with live parts.
Compliance is checked by inspection, and by the tests of 9.2 to 9.4, as applicable.
9.1
An accessible part is not considered to be live if:
– the part is supplied with safety extra-low voltage, provided that
• or a.c., the peak value of the voltage does not exceed 42 V;
• for d.c., the voltage does not exceed 42 V;
or
– he part is separated from live parts by protective impedance.
In the case of protective impedance, the current between the part and the supply source shall not exceed
2 mA for d.c., and its peak value shall not exceed 0,7 mA for a.c., and moreover:
– for voltages having a peak value over 42 V up to and including 450 V, the capacitance shall not
exceed 0,1 µF;
– for voltages having a peak value over 450 V up to and including 15 kV, the discharge shall not
exceed 45 µC.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 52 页 -->
Compliance is checked by operating the tool at rated voltage. Voltages and currents are measured
between the relevant parts and either pole of the supply source. Discharges are measured immediately
after the interruption of the supply.
9.2
The requirement of 9.1 applies for all positions of the tool when it is operated as in normal use, even
after removal of detachable parts.
Lamps located behind a detachable cover are not removed, provided the tool can be isolated from the
supply by means of a plug or an all-pole switch. However, during insertion or removal of lamps which are
located behind a detachable cover, protection against contact with live parts of the lamp cap shall be
ensured.
This excludes the use of screw type fuses and screw-type miniature circuit breakers which are accessible
without the aid of a tool.
The test finger of Figure 1 is applied without appreciable force, the tool being in every possible position.
Through openings, the test finger is applied to any depth that the finger will permit, and it is rotated or
angled before, during, and after insertion to any position.
If the opening does not allow the entry of the finger, the force on the finger in the straight position is
increased to 20 N and the test with the finger bent repeated.
It shall not be possible to touch with the test finger live parts or live parts protected only by lacquer,
enamel, ordinary paper, cotton, oxide film, beads or sealing compound.
Lacquer, enamel, ordinary paper, cotton, oxide film on metal parts, beads and sealing compound, except
self-hardening resins, are not considered to give the required protection against contact with live parts.
9.3
For openings in class II tools or class II constructions, except for those giving access to lamp caps or
live parts in socket-outlets of class I tools, the test pin of Figure 2 is applied without appreciable force. It
shall not be possible to touch live parts with the test pin.
9.4
In addition, class II tools and class II constructions shall be so constructed and enclosed that there is
adequate protection against accidental contact with basic insulation, and metal parts separated from live
parts by basic insulation only.
Parts which are not separated from live parts by double insulation or reinforced insulation shall not be
accessible.
Compliance is checked by inspection and by applying the test finger of Figure 1.
This requirement applies for all positions of the tool when it is operated as in normal use, even after
removal of detachable parts.
Starting
10.1
Motors shall start under all normal voltage conditions which may occur in use.
Compliance is checked by operating the tool with no-load 10 times at a voltage equal to 0,85 times rated
voltage, regulating devices, if any, being set as in normal use.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
In all cases, the tool shall function safely and correctly.

<!-- 第 53 页 -->
10.2
Centrifugal and other automatic starting switches shall operate reliably, and without contact
chattering.
Tools provided with a centrifugal or other automatic starting switch are, in addition, operated 10 times at a
voltage equal to 1,1 times rated voltage. The interval between consecutive starts is made sufficiently long
to prevent undue heating.
In all cases, the tool shall function safely and correctly.
10.3
Overload protection devices shall not operate under normal starting conditions.
The tests of 10.1 and 10.2 check compliance with this requirement.
Input and current
The rated power input or rated current shall be at least 110% of the measured no-load input or current.
For tools marked with one or more rated voltage ranges, the test is made at both the upper and lower limits
of the ranges, unless the marking or the rated power input is related to the mean value of the relevant
voltage range, in which case the test is made at a voltage equal to the mean value of that range.
Compliance is checked by measuring the power input or current of the tool when stabilized while all
circuits which can operate simultaneously are in operation.
Heating
12.1
Tools shall not attain excessive temperatures under normal load.
Compliance is checked by determining the temperature rise of the various parts under the conditions
specified in 12.2 to 12.5 immediately followed by the test of clause 13 with the tool in the "on" position and
under the following conditions:
For single-phase tools and for three-phase tools suitable for single-phase supply: S1 of Figure 3 in the “on”
position, for three-phase tools with the three sections connected in parallel.
For three-phase tools not suitable for single-phase supply: a, b and c in Figure 4 in the "on" position,
repeated with each of the switches a, b, c open in turn, the other two switches being closed.
For heating elements, the measurements are repeated with each of the switches a, b and c open in turn,
the other two switches being closed.
12.2
The tool is operated in still air under normal load. While the torque is maintained, the voltage is then
adjusted to 0,94 times the rated voltage or 1,06 times the rated voltage, or the mean of the rated voltage
range, whichever is the most unfavourable.
Heating elements, if any, are operated under the conditions specified in clause 11 of IEC 60335-1, when
the tool is operated at a voltage equal to 1,06 times rated voltage.
12.3
Temperature rises, other than those of windings, are determined by means of fine-wire
thermocouples so chosen and positioned that they have the minimum effect on the temperature of the part
under test.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 54 页 -->
The temperature rise of electrical insulation, other than that of windings, is determined on the surface of
insulation, at places where failure could cause a short circuit, contact between live parts and accessible
metal parts, bridging of insulation, or reduction of creepage distances or clearances below the values
specified in 28.1.
Temperature rises of windings are determined by the resistance method, unless the windings are non-
uniform, or the method involves severe complications to make the necessary connections for the
resistance measurement. In that case, the measurement is made by thermocouples.
Such temperature rises are determined by means of fine-wire thermocouples so chosen and positioned
that they have the minimum effect on the temperature of the part under test.
In determining the temperature rises of handles, knobs, grips and the like, consideration is given to all
parts which are gripped in normal use, and, if of insulating material, to those parts in contact with hot
metal.
NOTE 1 If it is necessary to dismantle the tool to position thermocouples, the power input is measured again to check that
the tool has been correctly reassembled.
NOTE 2 The point of separation of the cores of a multicore cord is an example of a place where thermocouples are
positioned.
12.4
The tool is operated:
– for the rated operating time for tools for short time operation;
– on consecutive cycles of operation, until steady conditions are established, for tools for
intermittent operation, the "on" and "off" periods being the rated "on" and "off" periods;
– until steady conditions are established for tools for continuous operation.
12.5
During the test, protective devices shall not operate. The temperature rises shall not exceed the
values shown in Table 1, except as allowed by 12.6.
Sealing compound, if any, shall not flow out.
Table 1
Maximum normal temperature rises
Parts
Temperature rise K
Windingsa), if the winding insulation according to IEC 60085 is:
– class 105
(65)
– class 120
(80)
– class 130
(85)
– class 155
– class 180
– class 200
– class 220
– class 250
Pins of appliance inlets:
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Table 1 Continued on Next Page

<!-- 第 55 页 -->
Table 1 Continued
Parts
Temperature rise K
– for hot conditions
– for cold conditions
Ambient of switches, temperature limitersb):
– without T-marking
– with T-marking
T-25
Rubber or polyvinyl chloride insulation of internal and external wiring, including
supply cords:
– without temperature rating c)
– with temperature rating (T)
T-25
Cord sheath used as supplementary insulation
Rubber, other than synthetic, used for gaskets or other parts, the deterioration of
which could affect safety:
– when used as supplementary insulation or as reinforced insulation
– in other cases
Lampholders E14 and B15:
– metal or ceramic type
– insulated type, other than ceramic
– with T-marking
T-25
Material used as insulation other than that specified for wires and windingsd)
– impregnated or varnished textile, paper or press board
– laminates bonded with:
• melamine-formaldehyde; phenol-formaldehyde or phenol-furfural resins
(175)
• urea-formaldehyde resin
(150)
– Printed circuit boards bonded with epoxy resin
– moulding of:
• phenol-formaldehyde with cellulose fillers
(175)
• phenol-formaldehyde with mineral fillers
(200)
• melamine-formaldehyde
(175)
• urea-formaldehyde
(150)
– polyester with glass-fibre reinforcement
– silicone rubber
– polytetrafluoroethylene
– pure mica and tightly sintered ceramic material when such materials are used as
supplementary insulation or reinforced insulation
– thermoplastic material e)
–
Wood, in general f)
Outer surface of capacitors g):
– with marking of maximum operating temperature (T)
T-25
– without marking of maximum operating temperature:
• small ceramic capacitors for radio and television interference suppression
• capacitors complying with IEC 60384-14 or 14.2 or IEC 60065
• other capacitors g)
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Table 1 Continued on Next Page

<!-- 第 56 页 -->
Table 1 Continued
Parts
Temperature rise K
External enclosure of tools without heating elements except handles held in normal
use
Handles, knobs, grips and the like which, in normal use, are continuously held:
– of metal
– of porcelain or vitreous material
– of moulded material, rubber or wood
Handles, knobs, grips and the like which, in normal use, are held for short periods
only (e.g. switches):
– of metal
– of porcelain or vitreous material
– of moulded material, rubber or wood
Parts in contact with oil having a flash-point of t °C
t-50
a) To allow for the fact that the average temperature of windings of universal motors, relays, solenoids, etc., is usually above the
temperature at the points on the windings where thermocouples are placed, the figures without parentheses apply when the
resistance method is used, and those within parentheses apply when thermocouples are used. For windings of vibrator coils and
a.c. motors, the figures without parentheses apply in both cases. For motors constructed so that the circulation of the air between
the inside and the outside of the case is prevented, but not necessarily sufficiently enclosed to be called airtight, the temperature
rise limits may be increased by 5 K.
b) T signifies the maximum operating temperature.
The ambient temperature of switches, thermostats and temperature limiters is the temperature of the air at the hottest point at a
distance of 5 mm from the surface of the switch and component concerned.
For the purpose of this test, switches and thermostats marked with individual ratings may be considered as having no marking for
the maximum operating temperature, if requested by the tool manufacturer.
c) This limit applies to cables, cords and wires complying with the relevant IEC standards; for others, it may be different.
d) The values in parentheses apply, if the material is used for handles, knobs, grips and the like, and is in contact with hot metal.
e) There is no specific limit for thermoplastic material, which has to withstand the tests of 29.1, for which purpose the temperature
rise must be determined.
f) The limit specified concerns the deterioration of wood, and it does not take into account deterioration of surface finishes.
g) There is no limit for the temperature rise of capacitors which are short-circuited in 18.10
If these or other materials are used, they shall not be subjected to temperatures in excess of the thermal capabilities as
determined by ageing tests made on the materials themselves.
The value of the temperature rise of a winding is calculated from the formula:
Δt = (R2 - R1/R1)/(k + t1) - (t2 - t1)
where:
Δt is the temperature rise;
R1 is the resistance at the beginning of the test;
R2 is the resistance at the end of the test;
k is the equal to 234,5 for copper windings, and 225 for aluminum windings;
t1 is the ambient temperature at the beginning of the test;
t2 is the ambient temperature at the end of the test.
At the beginning of the test, the windings are to be at ambient temperature. It is recommended that the resistance of windings at
the end of the test be determined by taking resistance measurements as soon as possible after switching off, and then at short
intervals so that a curve of resistance against time can be plotted for ascertaining the resistance at the instant of switching off.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
12.6
If the windings are classified according to IEC 60085 and the temperature rise does not exceed the
value in Table 1, the following test is not necessary.

<!-- 第 57 页 -->
Three additional samples are subjected to the following tests.
a) The samples are dismantled as far as is possible without damaging any part. Windings are kept
for 10 days (240 h) in a heating cabinet, the temperature of which is (80 ± 1) °C in excess of the
temperature rise of the windings determined according to 12.3.
b) After this treatment, the samples are reassembled and no interturn short circuit shall occur.
Interturn short circuits may be detected by means of a winding tester.
c) The samples are then subjected to a humidity treatment as specified in 14.3.
d) After this treatment, they shall withstand the tests of Clauses 13 and 15.
Faults which may occur in insulation, which did not show an excessive temperature rise during the test of
12.3, are ignored and are repaired, if necessary, in order to complete the tests of this subclause.
Leakage current
13.1
The leakage current shall not be excessive.
Compliance is checked by the following test at a supply voltage equal to 1,06 times rated voltage.
The leakage current test is made with a.c. unless the tool is for d.c. only, in which case the test is not
made.
Protective impedance is disconnected from live parts before carrying out the tests.
It is recommended that the tool be supplied through an isolating transformer; otherwise, it must be
insulated from earth.
13.2
The leakage current is measured by means of the circuit of Figure 10 between any pole of the
supply and accessible metal parts and metal foil with an area not exceeding 20 cm × 10 cm in contact with
accessible surfaces of insulating material, connected together.
The metal foil has the largest area possible on the surface under test, without exceeding the dimensions
specified. If its area is smaller than the surface under test, it is moved so as to test all parts of the surface.
The heat dissipation of the tool shall, however, not be affected by the metal foil.
Three-phase tools, which are suitable for single-phase supply, are tested as single-phase tools with the
three sections connected in parallel. For single-phase tools and three-phase tools to be tested as single-
phase tools, the leakage current is measured with the selector switch shown in Figure 3, in each of the
positions 1 and 2, and the switch SI in "on" position.
For three-phase tools not suitable for single-phase supply, the leakage current is measured according to
Figure 4 with the switches a, b and c in "on" position. For tools intended to be connected in star connection
only, the neutral is not connected.
The leakage current is measured within 5 s after the application of the test voltage and shall not exceed
the following values:
– to accessible metal parts and metal foil:
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
• for class I tools 0,75 mA;
• for class II tools 0,25 mA;

<!-- 第 58 页 -->
• for class III tools 0,5 mA.
If the tool incorporates one or more capacitors, and is provided with a single-pole switch, the
measurements are repeated with the switch in the "off" position.
13.2DV D2 Modification: Replace the class I tools item with the following:
• for class I tools 0,5 mA;
Moisture resistance
14.1
The enclosure of the tool shall provide the degree of protection against moisture in accordance with
the classification of the tool.
Compliance is checked by the appropriate treatment specified in 14.1.2, with the tool conditions as in
14.1.1.
14.1.1
The tool is not connected to the supply.
Tools are turned continuously through the most unfavourable positions during the test.
Tools with type X attachment are fitted with the lightest permissible type of flexible cord of the smallest
cross-sectional area specified in 25.2; other tools are tested as delivered.
Electrical components, covers and other parts which can be removed without the aid of a tool are removed
and subjected, if necessary, to the relevant treatment with the main part.
14.1.2
Tools other than IPX0 are subjected to tests of IEC 60529 as follows:
– IPX1 tools are subjected to the test described in 14.2.1;
– IPX2 tools are subjected to the test described in 14.2.2;
– IPX3 tools are subjected to the test described in 14.2.3;
– IPX4 tools are subjected to the test described in 14.2.4;
– IPX5 tools are subjected to the test described in 14.2.5;
– IPX6 tools are subjected to the test described in 14.2.6;
– IPX7 tools are subjected to the test described in 14.2.7.
For this last test, the tool is immersed in water containing approximately 1,0% NaCl.
Immediately after the appropriate treatment, the tool shall withstand the electric strength test of clause 15,
and inspection shall show that there is no trace of water on insulation which could result in a reduction of
creepage distances and clearances below the values specified in 28.1.
Tools which are not subject to spillage of liquid in normal use are allowed to stand in normal test-room
atmosphere for 24 h before being subjected to the test of 14.3.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 59 页 -->
14.2
Tools subject to spillage of liquid in normal use shall be so constructed that such spillage does not
affect their electrical insulation.
Compliance is checked by the following test:
Tools incorporating an appliance inlet are fitted with an appropriate connector and flexible cord; tools with
type X attachment are fitted with the lightest permissible type of flexible cord of the smallest cross-
sectional area specified in 25.2; other tools are tested as delivered.
Electrical components, covers and other parts which can be removed without the aid of a tool are
removed, except those fulfilling the test of 21.22.
The liquid container of the tool is completely filled with water containing approximately 1% NaCl, and a
further quantity, equal to 15% of the capacity of the container, or 0,25 l, whichever is the greater, is poured
in steadily over a period of 1 min.
Immediately after this treatment, the tool shall withstand an electric strength test as specified in clause 15,
and inspection shall show that there is no trace of water on insulation which could result in a reduction of
creepage distances and clearances below the values specified in 28.1.
The tool is allowed to stand in normal test-room atmosphere for 24 h before being subjected to the test of
14.3.
14.3
Tools shall be proof against humid conditions which may occur in normal use.
Compliance is checked by the following humidity test.
Cable entries, if any, are left open; if knock-outs are provided, one of them is opened.
Electrical components, covers, and other parts which can be removed without the aid of a tool are
removed and subjected, if necessary, to the humidity test with the main part.
The humidity treatment is carried out in a humidity cabinet containing air with a relative humidity of (93
±2)%, obtained e.g. by placing in the humidity cabinet a saturated solution of Na2SO4 or KNO3 in water,
having a sufficiently large contact surface with the air. The temperature of the air, at all places where
samples can be located, is maintained within 1 K of any convenient value t between 20°C and 30°C. In
order to achieve the specified conditions within the cabinet, it is necessary to ensure constant circulation of
the air within and, in general, to use a cabinet which is thermally insulated.
Before being placed in the humidity cabinet, the sample is brought to a temperature between t and
(t + 4)° C. The tool is considered to be brought to the specified temperature by keeping it at this
temperature for at least 4 h before the humidity treatment.
The tool is kept in the cabinet for 48 h.
Immediately after this test, the tool shall withstand the tests of clause 13 at rated voltage or the mean of
the rated voltage range with the tool switch in the "on" position and under the following conditions:
For single-phase tools and for three-phase tools to be tested as single-phase tools: S1 of Figure 3 in the
"off" position.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
For three-phase tools not suitable for single-phase supply: a in Figure 4 in the "on" position, b and c in "off"
position.

<!-- 第 60 页 -->
Then the tool shall withstand the test of clause 15 in the humidity cabinet, or in the room in which the tool
was brought to the prescribed temperature after reassembly of those parts which may have been
removed.
14.4
Liquid systems shall not subject the user to an increased risk of electrical shock during foreseeable
misuse.
Compliance is checked by the following test:
The residual current device, if any, shall be disabled during the test.
The tool is operated at rated voltage with approximately 1,0% NaCl solution in the following modes if
applicable:
• after overfilling of the fluid reservoir by 15% of the capacity of the container, or by 0,25 l,
whichever is the greater;
• omission of a washer or other user removable part;
• mis-assembly of liquid system connections routinely made by the user.
In each mode, the tool is operated for 1 min in all positions consistent with the relevant part 2 and the
manufacturer's instructions while monitoring the leakage current as in Clause 13. During the test the
leakage current shall not exceed:
• 2 mA for a class II tool;
• 5 mA for a class I tool.
Following this test, the tool shall meet the test of 13.1 after being allowed to dry for 24 h at ambient
temperature.
14.5
Liquid systems shall be constructed of components capable of withstanding the pressure in normal
use without leaking.
Compliance is checked by the following test:
The liquid system is closed and an approximately 1,0% NaCl solution at a hydrostatic pressure equal to
twice the pressure stated in 8.12.2 d) 1) is applied for 1 h. The leakage current of accessible parts is
measured as described in Clause 13. During the test the leakage current shall not exceed:
• 2 mA for a class II tool;
• 5 mA for a class I tool.
Following this test, the tool shall meet the test of 13.1 after being allowed to dry for 24 h at ambient
temperature.
The residual current device, if any, shall be disabled during the test.
14.6
Residual current devices used to provide protection from shock in the case of failure of the liquid
system shall comply with IEC 61540 and shall meet the following requirements a) to c):
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
a) The RCD shall disconnect both mains conductors, but not the earth conductor if provided, when
the leakage exceeds 10 mA and with a maximum response of 300 ms.

<!-- 第 61 页 -->
b) The RCD shall be reliable for its intended use.
Compliance is checked by inspection.
Electric strength
15.1
The electric strength shall be adequate.
Compliance is checked by the tests of 15.2.
Protective impedance is disconnected from live parts before carrying out the tests.
The tests are made on the tools at room temperature and not connected to the supply.
Accessible parts of insulated material are covered with metal foil.
Points of application
1. Between live parts and accessible parts separated from live
parts by
2. For parts with double insulation, between metal parts
separated from live parts by basic insulation only, and
3. Between metal enclosures or covers lined with insulating
material and metal foil in contact with the inner surface of the
lining, if the distance between live parts and these metal
enclosures or covers, measured through the lining, is less than
the appropriate clearance as specified in 28.1
APRIL 30, 2020
CAN/CSA-C22.2 No. 60745-1-07 ♦UL 60745-1
Compliance is checked by inspection and the test of 9.9.2 of IEC 61540. In addition, during the test,
the earthing conductor shall not become disconnected.
Compliance is checked at rated voltage by operating the residual current device under conditions
of simulated leakage as in (a) above during conditions of locked rotor of the tool for 50 cycles. The
residual current device shall operate correctly for all cycles.
c) This requirement is considered fulfilled if the residual current device is fixed to the tool or the
power supply cord connected to the tool.
Where fitted in the supply cord the residual current device shall be provided with Type Y
attachment or Type Z attachment for connection with the supply cord and interconnecting cord.
15.2
The insulation is subjected for 1 min to a voltage of substantially sinusoidal waveform, having a
frequency of 50 Hz or 60 Hz. The value of the test voltage and the points of application are shown in Table
2, unless otherwise specified.
Table 2
Test voltages
Test Voltage (V)
Class III tools
and construction
Class II tools and
construction
Other tools
– basic insulation only
–
1 250
– reinforced insulation
–
3 750
3 750
– live parts
–
1 250
1 250
– accessible parts
–
2 500
2 500
–
2 500
1 250
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Table 2 Continued on Next Page

<!-- 第 62 页 -->
Table 2 Continued
Test Voltage (V)
Class III tools
and construction
Class II tools and
Points of application
construction
Other tools
4. Between metal foil in contact with handles, knobs, grips and
the like and their shafts, if these shafts can become live in the
event of an insulation fault
–
2 500
2 500
5. Between accessible parts and internal diameter of cord guard
wrapped with metal foil
–
2 500
1 250
6. Between the point where a winding and a capacitor are
connected together, if a resonance voltage U occurs between this
point and any terminal for external conductors, and
– accessible parts a)
–
–
2 U + 1 000
– metal parts separated from live parts by basic insulation only
–
2 U + 1 000
–
a) The test between the point where a winding and a capacitor are connected together, and accessible parts or metal parts, is only
made where the insulation is subjected to the resonance voltage under normal running conditions. Other parts are disconnected,
and the capacitor is short-circuited.
Initially, not more than half the prescribed voltage is applied, then it is raised rapidly to the full value.
No flashover or breakdown shall occur during the test.
The high-voltage transformer used for the test must be so designed that, when the output terminals are
short-circuited after the output voltage has been adjusted to the appropriate test voltage, the output
current is at least 200 mA.
The overcurrent relay must not trip when the output current is less than 100 mA.
Care is taken that the r.m.s. value of the test voltage applied is measured within ±3%.
Care is taken that the metal foil is so placed that no flashover occurs at the edges or the edges of the
insulation.
For class II construction incorporating both reinforced insulation and double insulation, care is taken that
the voltage applied to the reinforced insulation does not overstress the basic insulation, or the
supplementary insulation.
In cases where basic insulation and supplementary insulation cannot be tested separately, the insulation
provided is subjected to the test voltages specified for reinforced insulation.
When testing insulating coatings, the metal foil may be pressed against the insulation by means of a
sandbag of such a size that the pressure is about 5 kPa (0,5 N/cm2). The test may be limited to places
where the insulation is likely to be weak, for example where there are sharp metal edges under the
insulation.
If practicable, insulating linings are tested separately.
For tools with heating elements incorporated, the test voltages specified in IEC 60335-1 apply to the
heating elements only and not to other parts of the tool.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 63 页 -->
Overload protection of transformers and associated circuits
Tools incorporating circuits supplied from a transformer shall be so constructed that, in the event of short
circuits which are likely to occur in normal use, excessive temperatures do not occur in the transformer, or
in the circuits associated to the transformer.
Examples of short-circuits which are likely to occur in normal use are the short-circuiting of bare or
inadequately insulated conductors of safety extra-low voltage circuits which are accessible, and the
internal short-circuiting of lamp filaments.
A failure of insulation complying with the requirements specified for basic insulation of class I or class II
construction is not, for the purpose of this requirement, considered as likely to occur in normal use.
Compliance is checked by applying the most unfavourable short circuit or overload which is likely to occur
in normal use, the tool being operated at a voltage equal to 1,06 times, or 0,94 times, rated voltage,
whichever is the more unfavourable.
The temperature rise of the insulation of the conductors of safety extra-low voltage circuits is determined,
and shall not exceed the relevant value specified in Table 1 by more than 15 K.
The winding temperature of transformers shall not exceed the value specified for windings in 18.9, except
for transformers which comply with IEC 61558-1.
NOTE Protection of transformer windings may be, for example, obtained by the inherent impedance of the winding, or by
means of fuses, automatic switches, thermal cut-outs or similar devices incorporated in the transformer, or similar devices
located inside the tool only accessible with the aid of a tool.
Endurance
17.1
Tools shall be so constructed that, in extended normal use, there will be no electrical or mechanical
failure that might impair compliance with this standard. The insulation shall not be damaged and contacts
and connections shall not work loose as a result of heating, vibrations, etc.
Moreover, overload protection devices shall not operate under normal running conditions.
Compliance is checked by the test of 17.2 and, for tools provided with a centrifugal or other starting switch,
also by the test of 17.3.
Immediately after these tests, the tool shall withstand an electric strength test as specified in clause 15,
the test voltages being, however, reduced to 75% of the specified values. Connections shall not have
worked loose, and there shall be no deterioration impairing safety in normal use.
17.2
The tool is operated intermittently with no load for 24 h of operation at a voltage equal to 1,1 times
rated voltage, and then for 24 h at a supply voltage equal to 0,9 times rated voltage.
The tool may be switched on and off by means of a switch other than that incorporated in the tool.
Each cycle of operation comprises an "on" period of 100 s and an "off" period of 20 s, the "off" periods
being included in the specified operating time.
The operating period for tools for short-time or intermittent operation is equal to the operating time, if this is
limited by the construction of the tool; otherwise, it is in accordance with the prescriptions given in part 2,
or with the marking, whichever is the more unfavourable.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 64 页 -->
During the test, the tool is placed in three different positions, the operating time, at each test voltage, being
approximately 8 h for each position.
During this test, replacement of the carbon brushes is allowed, and the tool is oiled and greased as in
normal use.
If the temperature rise of any part of the tool exceeds the temperature rise determined during the test of
12.1, forced cooling or rest periods are applied, the rest periods being excluded from the specified
operating time.
During these tests, overload protection devices shall not operate.
NOTE The change of position is made to prevent abnormal accumulation of carbon dust in any particular place. Examples
of the three positions are horizontal, vertically up and vertically down.
17.3
Tools provided with a centrifugal or other automatic starting switch are started 10 000 times under
normal load, and at a voltage equal to 0,9 times rated voltage, the operating cycle being that specified in
17.2.
Abnormal operation
18.1
Tools shall be so designed that the risk of fire and mechanical damage impairing safety or the
protection against electric shock as a result of abnormal operation is obviated as far as is practicable.
Fuses, thermal cut-outs, overcurrent protection devices or the like, incorporated into the tool, may be used
to provide the necessary protection.
Compliance is checked by the following tests of 18.2 to 18.9.
18.2
Tools incorporating heating elements are subjected to the tests of 18.3 and 18.4. Moreover, tools
2, are subjected to the tests of 18.5, and where applicable, to the test of 18.6.
Only one abnormal condition is simulated each time. If more than one of the tests are applicable to the
same tool, these tests are made consecutively.
Unless otherwise specified, the tests are continued until a non-self-resetting thermal cut-out operates, or
until steady conditions are established. If, during the test, a heating element or an intentionally weak part is
permanently open-circuited, the relevant test is repeated on a second sample. This second test shall be
terminated in the same way, unless the test is otherwise satisfactorily completed.
An intentionally weak part is a part intended to fail under conditions of abnormal operation so as to prevent
the occurrence of a condition which could impair compliance with this standard. Such a part may be a
replaceable component, such as a resistor, a capacitor, or a thermal link, or a part of a component to be
replaced, such as an inaccessible and non-resettable thermal cut-out incorporated in a motor.
18.3
Tools with heating elements are tested under the conditions specified in clause 12, but with
restricted heat dissipation. The supply voltage, determined prior to the test, is that required to provide a
power input of 0,85 times the rated power input under normal operation, when steady conditions have
been established. This voltage is maintained throughout the test.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
The tool is allowed to cool down to approximately room temperature before being subjected to the test of
18.4.

<!-- 第 65 页 -->
18.4
The test of 18.3 is repeated, but with a supply voltage, determined prior to the test, equal to that
required to provide a power input of 1,24 times rated power input under normal operation, when steady
conditions have been established. This voltage is maintained throughout the test.
18.5
The tool is tested under the conditions specified in clause 12, under normal operation, the supply
voltage being such that the power input is 1,15 times rated power input, but with any control which limits
the temperature during the test of clause 12 short-circuited.
If the tool is provided with more than one control, these are short-circuited in turn.
18.6
Unless an all-pole disconnection occurs during the test of 18.5 for class I tools with tubular
sheathed and embedded heating elements, but which are not intended to be permanently connected to
fixed wiring, the test of 18.5 is repeated, with the controls which limit the temperature during the test of
clause 12 not short-circuited, and one end of the element connected to earth. This test is repeated with the
polarity of the supply to the tool reversed and with the other end of the element connected to earth.
18.7
The following test is performed with cutting tools, such as sawblades, grinding wheels, etc.,
removed.
– Tools incorporating a commutator motor are operated at a voltage equal to 1,3 times rated
voltage, or the upper limit of the voltage range, for 1 min at no-load.
After these tests of 18.2 to 18.7, the safety of the tool shall not have been impaired, in particular windings
and connections shall not have worked loose. After these tests, the tool need not be capable of further
use.
18.8
The following categories of tools incorporating induction motors and:
a) with a starting torque less than the full-load torque; or
b) started by hand; or
c) provided with moving parts which are liable to be jammed, or where the moving parts can be
stopped by hand, the motor remaining switched on during this operation;
are connected, starting from cold, to their rated voltage or the upper limit of their rated voltage
range with the moving parts locked
• for 30 s for tools that are operated by hand during use;
• for 5 min for tools that are attended during use.
At the end of the test period specified, or at the instant of operation of fuses, thermal cut-outs, motor
protection devices, and the like, the temperature of the windings shall not exceed the values shown in
Table 3.
18.9
Tools incorporating three-phase motors are operated, starting from cold,
• for 30 s, if they are kept switched on by hand or continuously loaded by hand;
• or otherwise, for 5 min,
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
with one phase disconnected, and under the torque producing normal load.

<!-- 第 66 页 -->
At the end of the test period specified, or at the instant of operation of fuses, thermal cut-outs, motor
protection devices, and the like, the temperature of the windings shall not exceed the values shown in
Table 3.
Table 3
Maximum winding temperature
Limiting temperature
°C
Class
Protection of windings
impedance
Protection by protective devices
which operate during the test
18.10
Electronic circuits shall be so designed and applied so that a fault condition will not render the tool
unsafe with regard to electric shock, fire hazard, mechanical hazard or dangerous malfunction.
Compliance is checked by evaluation of the fault conditions specified in 18.10.2 for all circuits or parts of
circuits, unless they comply with the conditions specified in 18.10.1.
If the safety of the tool under any of the fault conditions depends on the operation of a miniature fuse-link
complying with IEC 60127-3, the test of 18.10.3 is made.
If a conductor of a printed circuit board becomes open-circuited, the tool is considered to have withstood
the particular test, provided all three of the following conditions are met:
– the base material of the printed circuit board withstands the test of Annex F;
– any loosened conductor does not reduce the creepage distances or clearances between live
parts and accessible metal parts below the values specified in Clause 28;
– the tool withstands the tests of 18.10.2 with the open-circuited conductor bridged.
NOTE Examination of the tool and its circuit diagram will reveal the fault conditions which have to be simulated, so that
testing can be limited to those cases which may be expected to give the most unfavourable result.
18.10.1
Fault conditions a) to f) specified in 18.10.2 are not applied to circuits or parts of circuits when
both of the following conditions are met:
– the electronic circuit is a low-power circuit as described below;
– the protection against electric shock, fire hazard, mechanical hazard or dangerous malfunction of
other parts of the tool does not rely on the correct functioning of the electronic circuit.
An example of a low-power circuit is shown in Figure 11 and is determined as follows.
The tool is operated at rated voltage or at the upper limit of the rated voltage range and a variable resistor,
adjusted to its maximum resistance, is connected between the point to be investigated and the opposite
pole of the supply source. The resistance is then decreased until the power consumed by the resistor
reaches a maximum. Any point closest to the supply at which the maximum power delivered to this resistor
does not exceed 15 W at the end of 5 s is called a low power point. The part of the circuit farther from the
supply source than a low power point is considered to be a low-power circuit.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 67 页 -->
The measurements are made from only one pole of the supply source, preferably the one that gives the
fewest low power points.
NOTE When determining the low power points, it is recommended to start with the points close to the supply source.
18.10.2
The following fault conditions are considered and, if necessary, applied one at a time,
consequential faults being taken into consideration:
a) short-circuit of creepage distances and clearances between conductive parts of different polarity,
if these distances are less than the values specified in Clause 28, unless the relevant part is
adequately encapsulated;
b) open-circuit at the terminal of any electronic component;
c) short-circuit of capacitors, unless they comply with IEC 60384-14;
d) short-circuit of any two terminals of an electronic component, other than an integrated circuit.
This fault is not applied between the two circuits of an optocoupler;
e) failure of triacs in the diode mode;
f) failure of an integrated circuit. In this case the possible hazardous situations of the tool are
assessed to ensure that safety does not rely on the correct functioning of such a component. All
possible output signals are considered under fault conditions within the integrated circuit. If it can
be shown that a particular output signal is unlikely to occur, then the relevant fault is not
considered.
Components such as thyristors and triacs are not subjected to fault condition f).
Fault condition f) is applied to encapsulated and similar components if the circuit cannot be assessed by
other methods.
NOTE Microprocessors are examples of integrated circuits.
Positive temperature coefficient resistors (PTC’s) are not short-circuited if they are used within their
manufacturer’s declared specification.
In addition, each low-power circuit is short-circuited by connecting the low power point to the pole of the
supply from which the measurements were made.
For simulation of the conditions, the tool is operated under the conditions specified in Clause 12, but at
rated voltage or at the most unfavourable voltage within the rated voltage range.
When any of the fault conditions are simulated, the duration of the test is:
– as specified in 12.4, but only if the fault cannot be recognized by the user, for example, change in
temperature;
– as specified in 18.8, if the fault can be recognized by the user, for example, when the motor
stops;
– until steady conditions are established, for circuits continuously connected to the supply mains,
for example, stand-by circuits.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
In each case, the test is ended if interruption of the supply occurs within the tool.

<!-- 第 68 页 -->
18.10.3
If safety of the tool depends upon the operation of a miniature fuse-link complying with IEC
60127-3 during any of the fault conditions specified in 18.10.2, the test is repeated but with the miniature
fuse-link replaced by an ammeter. If the current measured
– does not exceed 2,1 times the rated current of the fuse-link, the circuit is not considered to be
adequately protected and the test is carried out with the fuse-link short-circuited;
– is at least 2,75 times the rated current of the fuse-link, the circuit is considered to be adequately
protected;
– is between 2,1 times and 2,75 times the rated current of the fuse-link, the fuse-link is short-
circuited and the test is carried out
• for the relevant period or for 30 s, whichever is the shorter, for quick acting fuse-links;
• for the relevant period or for 2 min, whichever is the shorter, for time lag fuse-links.
In case of doubt, the maximum resistance of the fuse-link has to be taken into account when determining
the current.
Other fuses are considered to be intentionally weak parts in accordance with 18.2.
NOTE The verification whether the fuse-link acts as a protecting device is based on the fusing characteristics specified in
IEC 60127-3, which also gives the information necessary to calculate the maximum resistance of the fuse-link.
18.10.4
Tools incorporating electronic devices shall be so designed that, in the event of a failure in the
electronic equipment, this shall not result in a hazard.
Compliance is checked by operating the tool for 1 min, at a voltage equal to the rated voltage or the mean
value of the voltage range, at no-load with the electronic device short-circuited.
The test is then repeated with the electronic device open-circuited.
Following the tests of 18.10.1 to 18.10.4, the tool shall show no damage due to fire, mechanical damage
impairing safety and protection against electric shock. Any current flowing through protective impedance
shall not exceed the limits specified in 9.1.
Where the tool incorporates a device for limiting speed should the electronic device fail to operate, the tool
is considered to have withstood the test when the said speed-limiting device operates during the test.
18.11
Switches or other devices for motor reversal shall withstand the stresses occurring when the
sense of rotation is reversed under running conditions where such a reversal is possible in normal use.
Compliance is checked by the following test:
The tool is operated at a voltage equal to rated voltage, or at the upper limit of the rated voltage range, at
no load; the device for reversing the sense of rotation being in such a position that the rotor rotates in one
direction at full speed.
The direction of the rotation is then reversed, without the device resting in an intermediate "off" position.
This operation sequence is performed 25 times.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
After the test, the switch shall have no electrical or mechanical failure.

<!-- 第 69 页 -->
18.12
A class I tool employing class II construction (see 5.10) or a class II tool shall be able to operate
under extreme overload conditions without impairing protection against electric shock.
Compliance is checked by the following test on a separate sample.
All fuses, thermal cut-outs, overload protectors and the like specified in 18.1 that are accessible to the user
without the aid of a tool shall be shorted.
The sample is connected to a minimum 12 kVA circuit. The tool is loaded to 160% of normal load current
for either 15 min or until the tool open-circuits or flame appears. If the tool will not operate at 160%, the tool
is stalled for 15 min or until the tool open-circuits or flame appears. If either condition occurs, immediately
de-energise the tool and, if flames appear, extinguish with CO2 extinguisher. The leakage current between
live parts and accessible parts, measured in accordance with Clause 13, is monitored throughout the test
and after the test until leakage current has stabilized or decreases. Leakage current shall not exceed
2 mA.
After the tool is cooled to room temperature, an electric strength test per clause 15 is performed between
live parts and accessible parts as follows:
– If a tool does not operate after 15 min, apply a 1 500 V electric strength test.
– If a tool operates after 15 min, apply a 2 500 V electric strength test.
18.12DV D1 Modification: Replace Clause 18.12 with Clauses 18.12DV.1 to 18.12DV.3
18.12DV.1 A class II tool or a class I tool employing class II construction (see 5.10) operated
under extreme overload conditions shall not impair protection against electric shock.
Compliance is checked by the test of Clause 18.12DV.2. In the case of a Class I tool
employing a Class II armature construction, the test of Clause 18.12DV.2 may, at the
manufacturer's option, be replaced by the alternative test of Clause 18.12DV.3.
18.12DV.2 All fuses, thermal cut-outs, overload protectors, and the like specified in Clause
18.1 that are accessible to the user without the aid of a tool shall be shorted.
The tool is connected to a minimum 12 kVA circuit.
I construction, is measured in accordance with Clause 13 and is monitored throughout the
test and after the test until the leakage current has stabilized or decreases. The leakage
current shall not exceed 2 mA.
The tool is loaded to 160% of normal load current for either 15 min or until the tool open
circuits or flame appears. If the tool will not operate at 160%, the tool is stalled for 15 min or
until the tool open-circuits or flame appears. If either condition occurs, immediately open
S1 and, if flames appear, extinguish with CO2 extinguisher.
After the tool is cooled to room temperature, an electric strength test in accordance with
Clause 15 is performed between live parts and those accessible parts that are not
grounded by class I construction as follows:
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
– If a tool does not operate after 15 min, apply a 1 500 V electric strength test.
– If a tool operates after 15 min, apply a 2 500 V electric strength test.

<!-- 第 70 页 -->
18.12DV.3 A sample of the armature is connected to a minimum 12 kVA circuit.
The leakage current between the commutator segments and the armature shaft, is
measured with 1,06 times the tool’s rated voltage applied between the commutator
segments, located 180° apart, and the armature shaft (see Figure 18.12DV.1). The leakage
current is monitored throughout the test and after the test until it has stabilized or
decreases. The leakage current shall not exceed 2 mA.
The armature is subjected to carry 160% of the rated current. The current is applied to the
commutator segments that are located 180° apart. The current, without further adjustment,
is applied for either 15 min or until the armature open-circuits or flame appears. If either
condition occurs, immediately open S1 and, if flames appear, extinguish with CO2
extinguisher.
After the armature is cooled to room temperature, a 1 500 V electric strength test in
accordance with Clause 15 is performed between the commutator segments and the
armature shaft.
Figure 18.12DV.1
Overload test of a class II armature
1 = Shaft contact
2 = Commutator contacts
3 = Insulating table
4 = Armature
L1, L2 = Voltage supply for leakage current measurement
L3, L4 = Voltage supply (variable) for armature load current
M = Circuit of Figure 10 for the leakage current meter
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 71 页 -->
Mechanical hazards
19.1
Moving and other dangerous parts shall, as far as is compatible with the use and mode of function
of the tool, be so arranged or enclosed that, in normal use, adequate protection against injury is provided.
Protective enclosures, covers, guards and the like shall possess adequate mechanical strength for their
intended purpose. They shall not be removable without the aid of a tool.
When used as protection of the working element, the guard shall have an easily accessible means of
accurate adjustment with the objective of minimizing access to the dangerous parts.
The use and adjustment of a guard shall not create other dangers, for example by reducing or obstructing
the operator's view, by transferring heat, or causing other predictable hazards.
All working elements, including special features or attachments intended as part of the tool, shall be
secured so that they cannot create dangers during normal use by moving, or being released, out of the
normal working constraints of the tool.
NOTE 1 Such dangers might be caused by vibration, reversal of motion, or electric braking.
Compliance is checked by inspection, by the tests of Clause 20 and by means of a test using the standard
test finger shown in Figure 1. It shall not be possible to touch dangerous moving parts with this finger. This
test is not applicable for dust collection openings with the dust collection devices removed, as they are
tested in accordance with 19.3.
NOTE 2 In some cases, specified in the relevant part 2, a rigid test finger with the same dimensions of the test finger in
Figure 1, but without any articulation, is used.
19.2
Accessible parts likely to be touched during normal use shall be free from sharp edges, burrs,
flashes and the like.
Compliance is checked by inspection.
19.3
It shall not be possible to reach the moving parts with the provisions for dust collection removed, if
any.
Compliance is checked by a test with the rigid finger shown in Figure 1. It shall not be possible to touch
dangerous moving parts with the test finger through dust collection openings after the removing of the
removable provisions.
19.4
Tools shall have adequate grasping surfaces to ensure safe handling during use.
Compliance is checked by inspection.
19.5
Tools shall be designed and constructed to allow, where necessary, a visual check of the contact of
the cutting tool with the workpiece.
Compliance is checked by inspection.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
19.6
For all tools where the relevant part 2 requires the tool to be marked with the rated no-load speed,
the no-load speed of the spindle at rated voltage or at the upper limit of the rated voltage shall not exceed
110% of the rated no-load speed.

<!-- 第 72 页 -->
Compliance is checked by measuring the speed of the spindle after the tool has been operating for 5 min
at no-load.
Mechanical strength
20.1
Tools shall have adequate mechanical strength, and shall be so constructed that they withstand
such rough handling as may be expected in normal use.
Compliance is checked by the tests specified in 20.2, 20.3 and 20.4.
Following the tests, the tool shall withstand an electric strength test as specified in clause 15, and shall
show no damage which could impair compliance with this standard; in particular, live parts shall not have
become accessible, as specified in clause 9.
Damage to the finish, small dents which do not reduce creepage distances or clearances below the values
specified in 28.1, or small chips which do not adversely affect protection against shock or moisture are
neglected.
The function of mechanical safety devices shall not be impaired thereby.
Cracks not visible to the naked eye and surface cracks in fibre-reinforced mouldings and the like are
ignored.
If a decorative cover is backed by an inner cover, a fracture of the decorative cover is neglected when the
inner cover withstands the test after removal of the decorative cover.
20.2
Blows are applied to the tool by means of the spring-operated impact test apparatus according to
clause 5 of IEC 60068-2-75.
The spring is so adjusted that it causes the hammer to strike with an impact energy as shown in Table 4.
Table 4
Impact energies
Parts to be tested
Impact energy
Nm
Brush caps
0,5 ±0,05
Other parts
1,0 ±0,05
Three blows are applied to every point of the enclosure which is likely to be weak.
Where necessary, blows are also applied to protective devices, handles, levers, knobs and the like.
20.3
A hand-held tool shall withstand being dropped three times on a concrete surface from a height of
1 m. The sample shall be positioned to vary the point of impact.
20.4
Brush holders and their caps shall have adequate mechanical strength.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Compliance is checked by inspection and, in case of doubt, by removing and replacing the brushes 10
times, the torque applied when tightening the cap being as shown in Table 5.

<!-- 第 73 页 -->
Table 5
Test torques
Blade width of test screwdriver
Torque
mm
(Nm)
Up to and including 2,8
0,4
over 2,8 up to and including 3,0
0,5
over 3,0 up to and including 4,1
0,6
over 4,1 up to and including 4,7
0,9
over 4,7 up to and including 5,3
1,0
over 5,3 up to and including 6,0
1,25
After this test, the brush holder shall show no damage impairing its further use, the thread, if any, shall not
be damaged and the cap shall show no cracks.
The blade width of the test screwdriver shall be as large as possible, but shall not exceed the length of the
recess in the cap. If, however, the thread diameter is smaller than the length of the recess, the blade width
shall not exceed this said diameter. The torque shall not be applied in jerks.
20.5
For all tools that are likely to cut into concealed wiring or their own cord, handles and grasping
surfaces, as specified in the instruction manual, shall have adequate mechanical strength in order to
provide insulation between the grasping area and the output shaft.
Compliance is checked by the following test:
A separate sample, at the discretion of the manufacturer, is to be subjected to a single impact on each
handle and each recommended grasping surface. The impacts are carried out from a height of 1 m onto a
concrete surface followed by an electric strength test according to Clause 15 using 1 250 V a.c. between
the grasping surfaces in contact with foil and the output shaft of the tool.
Construction
21.1
Tools which can be adjusted to suit different voltages, or to different speeds, shall be so constructed
that accidental changing of the setting is unlikely to occur, if such a change might result in a hazard.
Compliance is checked by inspection and by manual test.
21.2
Tools shall be so constructed that accidental changing of the setting of control devices is unlikely to
occur.
Compliance is checked by manual test.
21.3
It shall not be possible to remove parts which ensure the required degree of protection against
moisture without the aid of a tool.
Compliance is checked by manual test.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
21.4
If handles, knobs and the like are used to indicate the position of switches or similar components, it
shall not be possible to fix them in a wrong position if this might result in a hazard.

<!-- 第 74 页 -->
Compliance is checked by inspection and by manual test.
21.5
Replacement of a flexible cable or cord requiring the moving of a switch which acts also as a
terminal for external conductors shall be possible without subjecting internal wiring to undue stress; after
repositioning the switch, and before reassembling the tool, it shall be possible to verify whether the internal
wiring is correctly positioned.
Compliance is checked by inspection and by manual test.
21.6
Wood, cotton, silk, ordinary paper and similar fibrous or hygroscopic material shall not be used as
insulation, unless impregnated.
Insulating material is considered to be impregnated if the interstices between the fibres of the material are
substantially filled with a suitable insulant.
Compliance is checked by inspection:
21.7
Asbestos shall not be used in the construction of tools.
Compliance is checked by inspection.
21.8
Driving belts shall not be relied upon to provide the required level of insulation.
This requirement does not apply if the tool incorporates a special design of belt which prevents
inappropriate replacement.
Compliance is checked by inspection.
21.9
Insulating barriers of class II tools, and parts of class II tools which serve as supplementary
insulation or reinforced insulation, and which might be omitted during reassembly after servicing, shall
either:
– be fixed in such a way that they cannot be removed without being seriously damaged; or
– be so designed that they cannot be replaced in an incorrect position, and that, if they are omitted,
the tool is rendered inoperable or manifestly incomplete.
Compliance is checked by inspection and by manual test.
Servicing includes replacement of components such as supply cords and switches.
This requirement is met if the barrier is so fixed that it can only be removed by breaking or cutting.
Fixing by means of rivets is allowed, provided that these rivets need not be removed when replacing the
brushes, capacitors, switches, non-detachable flexible cables and cords and the like.
Fixing by means of an adhesive is only allowed if the mechanical strength of the joint is equal to that of the
barrier.
An adequate internal lining of insulation material, or an adequate internal insulating coating on metal
enclosures, is considered to be an insulating barrier provided that the coating cannot easily be removed by
scraping.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 75 页 -->
For class II tools, a sleeve on an insulated internal conductor, other than the core of an external flexible
cable or cord, is considered to be an adequate insulating barrier, if it can only be removed by breaking or
cutting, or if it is clamped at both ends.
Ordinary lacquering on the inside of metal enclosures, varnished cambric, flexible resin-bonded paper, or
the like are not considered to be insulating barriers.
21.10
Inside the tool, the sheath (jacket) of a flexible cable or cord shall only be used as supplementary
insulation where it is not subject to undue mechanical or thermal stresses.
Compliance is checked by inspection.
21.11
Any assembly gap with a width greater than 0,3 mm in supplementary insulation shall not be
coincidental with any such gap in basic insulation, neither shall any such gap in reinforced insulation give
direct access to live parts.
Compliance is checked by inspection and measurement.
21.12
Class I tools shall be so constructed that, should any wire, screw, nut, washer, spring or similar
part become loose or fall out of position, it cannot become so disposed that accessible metal is made live.
Class II tools or class II constructions shall be so constructed that, should any such part become loose or
fall out of position, it cannot become so disposed that creepage distances or clearances over
supplementary insulation or reinforced insulation are reduced to less than 50% of the values specified in
28.1.
Class II tools or class II constructions, other than those of the all-insulated type, shall be provided with
insulating barriers between accessible metal and motor parts and other live parts.
For class I tools, this requirement can be met by the provision of barriers, or by fixing the parts adequately,
and by providing sufficiently large creepage distances and clearances.
It is not to be expected that two independent parts will become loose or fall out of position at the same
time. For electrical connections, spring washers are not considered to be adequate for preventing the
loosening of the parts.
Wires are considered as likely to become free from terminals or soldered connections, unless they are
held in place near to the terminal or termination, independent of the terminal connection or solder.
Short rigid wires are not regarded as liable to come away from a terminal, if they remain in position when
the terminal screw is loosened.
Compliance is checked by inspection, by measurement and by manual test.
21.13
Supplementary insulation and reinforced insulation shall be so designed or protected that they are
not likely to be impaired by deposition of dirt, or by dust resulting from wear of parts within the tool, to such
an extent that creepage distances or clearance are reduced below the values specified in 28.1.
Ceramic material not tightly sintered and similar materials, and beads alone, shall not be used as
supplementary insulation or reinforced insulation.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 76 页 -->
Parts of natural or synthetic rubber used as supplementary insulation shall be resistant to ageing, or be so
arranged and dimensioned that creepage distances are not reduced below the values specified in 28.1,
even if cracks occur.
Insulating material in which heating conductors are embedded serves as basic insulation, and shall not be
used as reinforced insulation.
Compliance is checked by inspection, by measurement and, for rubber, by the following test:
Parts of rubber are aged at a temperature of (100 ± 2) ° C for 70 h. After the test, the samples are
examined, and shall show no crack visible to the naked eye.
NOTE In case of doubt with regard to materials other than rubber, special tests may be made.
21.14
Tools shall be so constructed that internal wiring, windings, commutators, slip rings and the like,
and insulation in general, are not exposed to oil, grease or similar substances.
If the construction necessitates that insulation be exposed to oil or grease or similar substance, as in gears
and the like, the oil or grease or substance shall have adequate insulating properties so that compliance
with the standard is not impaired, and shall have no effect on insulation.
Compliance is checked by inspection and by the tests of this standard.
21.15
It shall not be possible to gain access to brushes without the aid of a tool.
Screw-type brush-caps shall be so designed that, when tightening, two surfaces are clamped together.
Brush-holders, which retain the brushes in position by means of a locking device, shall be so designed that
the locking does not depend upon the brush-spring tension, if the loosening of the locking device might
make accessible metal parts live.
Screw-type brush-caps, which are accessible from the outside of the tool, shall be of insulating material, or
be covered with insulating material of adequate mechanical and electrical strength; they shall not project
beyond the surrounding surface of the tool.
Compliance is checked by inspection and by manual test, the properties of the insulating material being
verified:
– by the tests of 20.2 and 20.4 for screw-type brush-caps which are accessible from the outside of
the tool;
– by the tests specified for supplementary insulation for class I tools and class III tools;
– by the tests specified for reinforced insulation for class II tools.
21.16
Tools employing liquid systems shall protect the user against the increased risk of shock due to the
presence of liquid under conditions of normal use and the faults of the liquid system.
Tools employing liquid systems shall be either:
• of class III construction; or
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
• of class I or class II construction and be provided with a residual current device and comply with
14.4, 14.5 and 14.6; or

<!-- 第 77 页 -->
• of class I or class II construction and be designed for use in combination with an isolating
transformer and comply with 14.4 and 14.5.
Compliance is checked by inspection.
21.17
Switches and reset buttons on non-self-resetting controls shall be so located that accidental
operation is unlikely to occur.
Compliance is checked by inspection, and by the following test:
The tool is connected to the power supply, placed in any possible position and dragged across a horizontal
surface.
Inadvertent operation of the switch shall not then occur.
21.18
Tools, other than those provided with a flexible shaft, shall be fitted with a mains switch which can
be switched off by the user without releasing his grasp on the tool. When a switch has a locking
arrangement to lock it in the "on" position, the requirement in 21.18 is considered as being met provided
the switch unlocks automatically when the trigger or actuating member is actuated.
Compliance is checked by inspection and by manual test.
21.18.1
Where there is a risk associated with continued operation, the switch shall not have any locking
device to lock it in the "on" position and it shall not remain in the "on" position when the trigger is released.
This shall be stated in the relevant part 2.
21.18.2
Where there is a risk associated with inadvertent starting, the switch shall have a locking device
to lock it on the "off" position. This shall be stated in the relevant part 2.
21.19
Tools shall be so designed that the protection against electric shock is not affected when screws
intended for replacement from the outside during routine servicing are replaced by screws having a
greater length.
Compliance is checked by inserting longer screws, without appreciable force, after which creepage
distances and clearances between live parts and accessible metal parts shall not have been reduced
below the values specified in 28.1.
21.20
If the tool is marked with the first numeral of the IP system, the relevant requirements of IEC 60529
shall be fulfilled.
Compliance is checked by making the relevant tests.
21.21
Tools shall be so designed that in normal use there is no risk of electric shock from charged
capacitors when touching the pins of the plug. Capacitors, having a rated capacitance less than or equal to
0,1 µF, are not considered to entail a risk of electric shock. This requirement does not apply to capacitors
complying with the requirements for protective impedance specified in 9.1 and 21.36.
Compliance is checked by the following test, which is made 10 times.
The tool is operated at rated voltage.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
The tool switch, if any, is then moved to the "off" position and the tool is disconnected from the supply by
means of the plug.

<!-- 第 78 页 -->
One second after disconnection, the voltage between the pins of the plug is measured with an instrument
which does not appreciably affect the value to be measured.
The voltage shall not exceed 34 V.
21.22
Non-detached parts, which provide the necessary degree of protection against electric shock,
moisture, or contact with moving parts, shall be fixed in a reliable manner, and shall withstand the
mechanical stress occurring in normal use.
Snap-in devices used for fixing such parts shall have an obvious locked position. The fixing properties of
snap-in devices used in parts which are likely to be removed during servicing shall not deteriorate.
Compliance is checked by the following tests:
Parts which are likely to be removed during servicing are disassembled and assembled 10 times before
the test is carried out.
Servicing includes replacement of the supply cord.
The tool is at room temperature. However, in cases where compliance may be affected by temperature,
the test is also carried out immediately after the tool has been operated under the conditions specified in
clause 12.
The test is applied to all parts which are likely to be detachable, whether or not they are fixed by screws,
rivets, or similar parts.
A force is applied without jerks for 10 s in the most unfavourable direction to those areas of the cover or
part which are likely to be weak. The force is as follows:
– push force 50 N;
– pull force
a) if the shape of the part is such that the fingertips cannot easily slip off 50 N;
b) if the projection of the part which is gripped is less than 10 mm in the direction of removal
30 N.
The push force is applied by means of a rigid test finger similar in dimensions to the standard test finger
shown in Figure 1.
The pull force is applied by a suitable means such as a suction cup, so that the test results are not
affected.
While the pull test of a) or b) is being applied, the test fingernail shown in Figure 7 is inserted in any
aperture or joint with a force of 10 N. The fingernail is then slid sideways with a force of 10 N; it is not
twisted or used as a lever.
If the shape of the part is such that an axial pull is unlikely, no pull force is applied, but the test fingernail
shown in Figure 7 is inserted in any aperture or joint with a force of 10 N, and is then pulled for 10 s by
means of the loop with a force of 30 N in the direction of removal.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
If the cover or part is likely to be subjected to a twisting force, a torque as detailed below is applied at the
same time as the pull or push force:

<!-- 第 79 页 -->
– for major dimensions up to and including 50 mm 2 Nm;
– for major dimensions over 50 mm 4 Nm.
This torque is also applied when the test fingernail is pulled by means of the loop.
If the projection of the part which is gripped is less than 10 mm, the above torque is reduced to 50% of the
value.
Parts shall not become detached, and they shall remain in the locked position.
21.23
Handles, knobs, grips, levers and the like shall be fixed in a reliable manner so that they will not
work loose in normal use, if loosening might result in a hazard.
Compliance is checked by inspection, by manual test, and by trying to remove the handle, knob, grip or
lever applying, for 1 min, a 30 N axial force either pushing or pulling.
21.24
Storage hooks and similar devices for flexible cords shall be smooth and well rounded.
Compliance is checked by inspection.
21.25
Current-carrying parts and other parts, the corrosion of which might result in a hazard, shall be
resistant to corrosion under normal conditions of use.
Compliance is checked by verifying that, after the tests of Clause 30, the relevant parts show no sign of
corrosion. Stainless steel and similar corrosion-resistant alloys and plated steel are considered to be
satisfactory for the purpose of this requirement.
NOTE Examples of causes of corrosion are the incompatibility of materials and effects of heating.
21.26
Void
21.27
Tools other than class II, having parts where reliance is placed upon safety extra-low voltage to
provide the necessary degree of protection against electric shock, shall be so designed that the insulation
between parts operating at safety extra-low voltage and other live parts complies with the requirements for
double insulation or reinforced insulation.
Compliance is checked by the tests specified for double insulation or reinforced insulation.
21.28
Parts separated by protection impedance shall comply with the requirements for double insulation
or reinforced insulation.
Compliance is checked by the tests specified for double insulation or reinforced insulation.
21.29
Void
21.30
Shafts of operating knobs, handles, levers and the like shall not be live unless the shaft is not
accessible when the knob, handle, lever and the like is removed.
Compliance is checked by inspection and by applying the test finger as specified in 9.2 after removal of the
knob, handle, lever, or the like, even with the aid of a tool.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 80 页 -->
21.31
For constructions other than those of class III, handles, levers and knobs which are held or
actuated in normal use shall not become live in the event of an insulation fault. If these handles, levers or
knobs are of metal, and if their shafts or fixings are likely to become live in the event of a basic insulation
fault, they shall either be adequately covered by insulating material, or their accessible parts shall be
separated from their shafts or fixings by insulation.
The covering or insulating material shall comply with the electric strength test in clause 15, Table 2 item 4,
but need not be insulation.
Compliance is checked by inspection, and if necessary, by the tests specified for insulation.
21.32
For all tools that are likely to cut into concealed wiring or their own cord, handles and grasping
surfaces, as specified in the instruction manual, shall be formed of insulating material or, when of metal,
shall be either adequately covered by insulating material or their accessible parts shall be separated by
insulating barrier(s) from accessible metal parts that may become live by the output shaft. These insulating
barriers are not to be regarded as basic, supplementary or reinforced insulation.
An insulated, stick type, auxiliary handle shall be provided with a flange having a height not less than 12
mm above the grasping surface between the grasping area and accessible parts that may become live by
the output shaft.
Compliance is checked by inspection and the tests of 20.5.
21.33
For class II tools, capacitors shall not be connected to accessible metal parts, and their casings, if
of metal, shall be separated from accessible metal parts by supplementary insulation.
This requirement does not apply to capacitors complying with the requirements for protective impedance
specified in 9.1 and 21.36.
Compliance is checked by inspection and by the tests specified for supplementary insulation.
21.34
Capacitors shall not be connected between the contacts of a thermal cut-out.
Compliance is checked by inspection.
21.35
Lampholders shall be used only for the connection of lamps.
Compliance is checked by inspection.
21.36
Protective impedance shall consist of at least two separate components, the impedance of which
is unlikely to change significantly during the lifetime of the tool. If any one of the components is short-
circuited or open-circuited, the values specified in 9.1 shall not be exceeded.
Resistors complying with 14.1 of IEC 60065 and capacitors complying with 14.2 of IEC 60065 are
considered to comply with this requirement.
Compliance is checked by inspection and by measurement.
21.37
Air intake shall not enable the ingress of foreign bodies that could impair the safety.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Compliance is checked by the following test:

<!-- 第 81 页 -->
It shall not be possible to insert a steel ball of 6 mm diameter through the air intake openings other than
those adjacent to the fan.
Internal wiring
22.1
Wireways shall be smooth and free from sharp edges.
Wires shall be protected so that they do not come into contact with burrs, cooling fins, etc., which may
cause damage to the insulation of conductors.
Holes in metal through which insulated wires pass shall be provided with bushings or, unless required
otherwise in part 2, shall have smooth, well-rounded edges. A radius of 1,5 mm is considered to be well
rounded.
Wiring shall be effectively prevented from coming into contact with moving parts.
Compliance is checked by inspection.
22.2
Internal wiring and electrical connections between different parts of the tool shall be adequately
protected or enclosed.
Compliance is checked by inspection.
22.3
Internal wiring shall be either so rigid and so fixed or insulated that, in normal use, creepage
distances and clearances cannot be reduced below the values specified in 28.1. The insulation, if any shall
be such that it cannot be damaged in normal use.
Compliance is checked by inspection, by measurement, and by manual test.
For insulated internal wiring, it is checked that either their insulation is electrically equivalent to the
insulation of the cords complying with IEC 60227 or IEC 60245, or it complies with the following electric
strength test.
A voltage of 2 000 V is applied for 15 min between the conductor and metal foil wrapped around the
insulation. There shall be no breakdown.
When sleeving is used as supplementary insulation on internal wiring, it shall be retained in position by
or cutting, or if it is clamped at both ends.
Compliance is checked by inspection and by manual test.
22.3DV DC Modification: Delete the fourth paragraph and replace the third paragraph with
the following:
Internal wiring shall comply with CSA C22.2 No. 38, CSA C22.2 No. 75, CSA C22.2 No. 127,
or CSA C22.2 No. 210 and UL 44, UL 83, or UL 758, as applicable.
22.4
Conductors identified by the colour combination green/yellow shall not be connected to terminals
other than earthing terminals.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Compliance is checked by inspection.

<!-- 第 82 页 -->
22.4DV DR Modification: Replace the first paragraph with the following:
Conductors identified by the colour green or combination green/yellow shall not be
connected to terminals other than earthing terminals.
22.5
Aluminium wires shall not be used for internal wiring. Windings of a motor are not considered as
internal wiring.
Compliance is checked by inspection.
22.6
Stranded conductors shall not be consolidated by lead-tin soldering where they are subjected to
contact pressure, unless the clamping means is so designed that there is no risk of bad contact due to cold
flow of the solder.
Consolidation of a stranded conductor by lead-tin soldering is allowed if spring terminals are used;
securing the clamping screws alone is not considered adequate.
Soldering of the tip of a stranded conductor is allowed.
Compliance is checked by inspection.
Components
23.1
Components shall comply with the safety requirements specified in the relevant IEC standards, as
far as they reasonably apply.
If components are marked with their operating characteristics, the conditions under which they are used in
the tool shall be in accordance with these markings, unless a specific exception is made.
23.1.1
Capacitors in auxiliary windings of motors shall be marked with their rated voltage and their rated
capacitance.
23.1.2
Fixed capacitors for radio interference suppression shall comply with IEC 60384-14.
23.1.3
Small lampholders similar to E10 lampholders shall comply with the requirements for E10
lampholders; they need not accept a lamp with E10 cap complying with the current edition of Standard
Sheet 7004-22 of IEC 60061.
23.1.4
Isolating transformers and safety isolating transformers shall comply with IEC 61558-1.
23.1.5
Appliance couplers other than those used for IPX0 tools shall comply with IEC 60309. Those used
for IPX0 shall comply with IEC 60320.
Where appliance couplers not standardized by IEC are used, the manufacturer shall inform the user in the
manufacturer.
23.1.6
Automatic controls not complying with IEC 60730-1 shall be tested according to this standard, and
additionally, according to 11.3.5 to 11.3.8 and clause 17 of IEC 60730-1. Controls may be tested
separately from the tool.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
The tests according to IEC 60730-1 are carried out under the conditions occurring in the tool.

<!-- 第 83 页 -->
For the tests of clause 17 of IEC 60730-1, the number of cycles to be used are:
– for thermostats, 10 000 cycles of operation;
– for temperature limiters, 1 000 cycles of operation;
– for self-resetting thermal cut-out, 300 cycles of operation;
– for non-self-resetting thermal cut-out which is manually reset, 10 cycles of operation.
Automatic controls which comply with the requirements of IEC 60730-1, and which are used in accordance
with their marking, are considered to meet the requirements of this standard (the term "marking" includes
documentation and declaration as specified in clause 7 of IEC 60730-1).
The tests of clause 17 of IEC 60730-1 are not carried out on automatic controls which operate during
clause 12, if the tool meets the requirements of this standard when they are short-circuited.
A specific exception with regard to the testing of thermostats and temperature limiters is made in footnote
b) of Table 1 of Clause 12.
23.1.7
The testing of components which have to comply with other standards is, in general, carried out
separately, according to the relevant standard as follows.
If the component is marked and used in accordance with its marking, it is tested in accordance with its
marking, the number of samples being that required by the relevant standard.
In particular, components not mentioned in Table 1 of clause 12 are tested as a part of that tool.
23.1.8
Where no IEC standard exists for the relevant component, or where the component is not
marked, or is not used in accordance with its marking, the component is tested under the conditions
occurring in the tool, the number of samples being, in general, that required by a similar specification.
23.1.9
For capacitors connected in series with a motor winding, it is verified that, when the tool is
operated at a voltage equal to 1,1 times rated voltage and under minimum load, the voltage across the
capacitor does not exceed 1,1 times the rated voltage of the capacitor.
23.1.10
Mains switches shall have adequate breaking capacity, and shall be switches for 50 000 cycles
of operation.
Compliance is checked by inspection and by the following test:
Mains switches are tested together with the tool at rated voltage or at the upper limit of the rated voltage
range of the tool.
The motor is then stalled, and the switch is operated 50 times, each "on" period being not more than 0,5 s,
and each "off" period being not less than 10 s.
If, in normal use, an electronic control device switches off the current before opening the main contacts,
the number of operations is reduced to five, with the electronic control device short-circuited.
After the test, the switch shall have no electrical or mechanical failure.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Mains switches marked with individual ratings are also tested in accordance with IEC 61058-1.

<!-- 第 84 页 -->
23.1.11
Switches, which have not been separately tested and found to comply with IEC 61058-1 under
the conditions occurring in the tool, shall comply with Annex I.
The test of 17.2.4.4 of IEC 61058-1 is carried out for 50 000 cycles of operation.
Switches intended for operation under no load, and which can be operated only with the aid of a tool, are
not subjected to the tests of clause 17 of IEC 61058-1. This applies also to such switches operated by
hand which are interlocked so that they cannot be operated under load, but switches without that interlock
are subjected to the test of 17.2.4.4 for 100 cycles of operation.
The tests of 17.2.4.4 of IEC 61058-1 are not carried out on a switch if the tool meets the requirements of
this standard when the switch is short-circuited.
23.2
Tools shall not be fitted with
– switches or automatic controls in flexible cords, however RCDs are allowed;
– devices which are designed to cause the protection device in the fixed wiring to operate in the
event of a fault in the tool;
– thermal cut-outs which can be reset by a soldering operation.
Compliance is checked by inspection.
23.3
Overload protection devices shall be of the non-self-resetting type.
Compliance is checked by inspection.
23.4
Plugs and socket-outlets used as terminal devices for heating elements, and plugs and socket-
outlets for extra-low voltage circuits, shall not be interchangeable with plugs and socket-outlets listed in
IEC 60884, and with connectors and tool inlets complying with the standard sheets of IEC 60320.
23.5
Motors connected to the supply mains, and having basic insulation which is inadequate for the rated
voltage of the tool, shall comply with the requirements of Annex B.
Compliance is checked by the tests of Annex B.
Supply connection and external flexible cords
24.1
Tools shall be provided with one of the following means of connection to the supply:
– a supply cord with a plug, for tools rated in voltage or frequency for connection to public supplies;
– a supply cord without a plug, if the tool is intended to be connected to non-public power supplies;
– an appliance inlet having at least the same degree of protection against moisture as required for
the tool, and having a locking device preventing inadvertent disconnection;
– a supply cord not exceeding 0,5 m and fixed with an in-line connector (cable coupler) and its
mating counterpart. The in-line connector shall have at least the same degree of protection against
moisture as required for the tool.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Compliance is checked by inspection and for locking devices with the pull test of 24.14.

<!-- 第 85 页 -->
24.1DV D2 Modification: Add the following sentence:
A supply cord shall be less than 0,5 m or greater than 1,8 m long.
24.2
Supply cords shall be assembled to the tool by one of the following methods:
– type X attachment;
– type Y attachment;
– type Z attachment, only for exchange-type tools, as allowed in part 2.
Supply cords with type X and type Y attachment may be either ordinary flexible cords or special cords and
only available from the manufacturer or his service agent. A special cord may also include a part of the
tool.
Compliance is checked by inspection and, if necessary, by manual test.
24.3
Plugs shall not be fitted with more than one flexible cord.
Compliance is checked by inspection.
24.4
Supply cords shall be not lighter than:
– ordinary tough rubber sheathed flexible cord (code designation 60245 IEC 53);
– ordinary polyvinyl chloride sheathed flexible cord (code designation 60227 IEC 53).
Polyvinyl chloride insulated flexible cords shall not be used for tools having external metal parts, the
temperature rise of which exceeds 75 K during the test of clause 12.
Compliance is checked by inspection and measurement.
If provided with a plug, power supply cords of single-phase tools having a rated current not exceeding 16 A
shall be provided with a plug complying with IEC 60884 or IEC 60309.
If plugs complying with IEC 60309 are fitted, the standard sheets to be applied are as follows:
– class I tools
Sheet 2 – I
– class II tools
Sheet 2
– class III tools
Sheet 2 – I
The body of the plug shall be of, or covered with, rubber, polyvinyl chloride or material having no less
mechanical strength.
Power supply cords of single-phase tools, having a rated current exceeding 16 A but not exceeding 63 A,
and of multi-phase tools having a rated current not exceeding 63 A, shall be provided with a plug
complying with IEC 60309, the standard sheets to be applied being as follows:
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 86 页 -->
– class I tools
Sheet 2 – III according to current
– class II tools
Sheet 2
– class III tools
Sheet 2 – III
Two-pole plugs, appliance inlets and connectors for cable couplers and plugs to standard sheet 2 are
allowed in class II tools.
24.4DV DR Modification: Replace 24.4 with the following:
Supply cords shall be not lighter than Junior Hard service cord in accordance with the
National Electrical Code, NFPA 70, and Hard Usage cord in accordance with the Canadian
Electrical Code, Part 1, CSA C22.1.
Attachment plugs and cords should be equal to or greater than the rating of the tool.
24.5
Supply cords shall have a nominal cross-sectional area not less than those shown in Table 6.
Table 6
Minimum cross-sectional area of supply cord
Rated current of the tool
Nominal cross-sectional area
A
mm2
Up to and including 6
0,75
Over 6 up to and including 10
Over 10 up to and including 16
1,5
Over 16 up to and including 25
2,5
Over 25 up to and including 32
Over 32 up to and including 40
Over 40 up to and including 63
Compliance is checked by measurement.
Table 6DV D1 Modification: Replace Table 6 with the following:
Table 6DV
Minimum cross-sectional area of supply cord
Rated current of the tool
Nominal cross-sectional area
A
AWG
Up to and including 10
Over 10 up to and including 13
Over 13 up to and including 18
Over 18 up to and including 25
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 87 页 -->
24.6
For class I tools, the supply cord shall be provided with a green/yellow core; it shall be connected to
the internal earthing terminal of the tool, and to the earthing contact of the plug.
Compliance is checked by inspection.
24.6DV DR Modification: Replace the first paragraph with the following:
For class I tools, the supply cord shall be provided with a green or green/yellow core; it
shall be connected to the internal earthing terminal of the tool and to the earthing contact
of the plug.
24.7
Conductors of supply cords shall not be consolidated by lead-tin soldering where they are subject to
contact pressure, unless the clamping means is so designed that there is no risk of a bad contact due to
cold flow of the solder.
Compliance is checked by inspection.
The requirement may be met by using spring terminals. Securing the clamping screws alone is not
considered adequate.
24.8
For all types of attachment, moulding together the supply cord to the enclosure or part of it shall not
affect the insulation of the cord.
Compliance is checked by inspection.
24.9
Inlet openings shall be provided with a bushing, or shall be so constructed that the protective
covering of the supply cord can be introduced without risk of damage.
Compliance is checked by inspection and by manual test.
24.10
Inlet bushings shall:
– be so shaped as to prevent damage to the supply cord;
– be reliably fixed;
– not be removable without the aid of a tool.
Compliance is checked by inspection and by manual test.
24.11
Void
24.12
Cord guards shall have adequate mechanical strength and shall retain these properties throughout
extended normal use.
Compliance is checked by the following test:
The part of the tool comprising the cable entry, fitted with the cord guard and the flexible cable or cord for
which the tool is designed, is fixed in the oscillating member of an apparatus similar to that shown in
Figure 9. The sample is so mounted that the axis of oscillation is tangential to the outer surface of the part
in which the cord guard is secured, and, when the oscillating member is at the middle of its travel, the axis
of the cable or cord where it leaves the cord guard is vertical.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 88 页 -->
A weight, having a mass equal to that of the tool, but not less than 2 kg or more than 6 kg, is attached to
the cable or cord.
The oscillating member is moved backwards and forwards through an angle of 90° (45° on either side of
the vertical), the number of flexings being 20 000 and the rate of flexing 60 per min. A flexing is one
movement, either backwards or forwards. After 10 000 flexings, the sample is turned through 90° about
the centre line of the cord guard.
After the test, the cord guard shall not have worked loose, and neither the cord guard nor the flexible cable
or cord shall show any damage which could impair compliance with this standard, except that not more
than 10% of the number of strands of each conductor may have been broken.
Immediately after this test, the cord anchorage and the terminal screws are loosened, without removing
the conductors of the flexible cable or cord. However, if the cord guard is clamped under the cord
anchorage, the cord anchorage is not loosened.
The tool is then lifted by the cord guard, without jerks, over a distance of approximately 500 mm in
approximately 1 s, and replaced on a support.
The operation is made 10 times.
During this test, the cord guard shall not slip out of its location.
24.13
Flexible cables or cords of tools shall be protected against excessive bending at the inlet opening
of the tool by means of a cord guard of insulating material.
The guards shall be fixed in a reliable manner, and shall be of such a design that they project outside the
tool for a distance beyond the inlet opening of at least five times the overall diameter of the cable or cord
delivered with the tool.
Compliance is checked by inspection, by measurement and by the following test:
A tool designed for a power supply cord is fitted with a cord guard, the flexible cable or cord being
approximately 100 mm longer than the guard.
The tool is so held that the axis of the cord guard, where the cable or cord leaves it, projects upwards at an
angle 45° to the horizontal when the cable or cord is free from stress.
A mass equal to 10 D2 g is then attached to the free end of the cable or cord. D is the external diameter of
the flexible cable supplied with the tool in mm.
If the cord guard is temperature sensitive, the test is made at a temperature of (23 ± 2) °C.
Immediately after the mass has been attached, the curvature of the cable or cord shall nowhere be less
than 1,5 D.
24.14
Tools provided with a supply cord shall have cord anchorages so that the conductors are relieved
from strain, including twisting, where they are connected within the tool, and that the insulation of the
conductors is protected from abrasion.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
It shall not be possible to push the cord into the tool to such an extent that the cord, or internal parts of the
tool, could be damaged.

<!-- 第 89 页 -->
Compliance is checked by inspection, by manual test, and by the following test:
The cord is subjected 25 times to a pull of the value shown in Table 7. The pulls are applied without jerks in
the most unfavourable direction each time for 1 s.
Immediately afterwards, the cord, other than that of an automatic cord reel, is subjected for 1 min to a
torque of the value shown in Table 7.
Table 7
Pull and torque value
Mass of tool
Pull
Torque
kg
N
Nm
Up to and including 1
0,1
Over 1 up to and including 4
0,25
Over 4
0,35
During the tests, the cord shall not be damaged.
After the tests, the cord shall not have been longitudinally displaced by more than 2 mm, and the
conductors shall not have moved over a distance of more than 1 mm in the terminals, nor shall there be
appreciable strain at the connection.
Creepage distances and clearances shall not be reduced below the value specified in 28.1.
For the measurement of the longitudinal displacement, a mark is made on the cord while it is subjected to
the pull, at a distance of approximately 2 cm from the cord anchorage or other suitable point, before
starting the tests.
After the tests, the displacement of the mark on the cord in relation to the cord anchorage or other point is
measured while the cord is subjected to the pull.
24.15
Cord anchorages shall either be so arranged that they are only accessible with the aid of a tool, or
be so designed that the cord can only be fitted with the aid of a tool.
Compliance is checked by inspection.
24.16
For type X attachments, cord anchorages shall be so designed or located that:
– replacement of the cord is easily possible;
– it is clear how the relief from strain and the prevention of twisting are to be obtained;
– they are suitable for the different types of cord which may be connected, unless the tool is so
designed that only one type of cord can be fitted;
– the cord cannot touch the clamping screws of the cord anchorage, if these screws are accessible,
or at least not separate from accessible metal parts by supplementary insulation;
– the cord is not clamped by a metal screw which bears directly on the cord;
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
– at least one part of the cord anchorage is securely fixed to the tool, unless it is part of the
specially prepared cord;

<!-- 第 90 页 -->
– screws, if any, which have to be operated when replacing the cord, do not serve to fix any other
component, unless, when omitted or incorrectly mounted, they render the tool inoperative or clearly
incomplete, or unless the parts intended to be fastened by them cannot be removed without the aid
of a tool during the replacement of the cord;
– in the case of labyrinths, these labyrinths cannot be bypassed in such a way that the test of 24.14
is not withstood;
– glands shall not be used as cord anchorages for power supply cords;
– for class I tools, they are of insulating material or are provided with an insulating lining, if
otherwise an insulation fault on the cord could make accessible metal parts live;
– for class II tools, they are of insulating material, or, if of metal, are insulated from accessible metal
parts by insulation complying with the requirements for supplementary insulation.
If, for type X attachment, the cord anchorage comprises one or more clamping member (s) to which
pressure is applied by means of one or more nuts engaging with studs, which are securely attached to the
tool, the cord anchorage is considered to have one part securely fixed to the tool, even if the clamping
member(s) can be removed from the studs.
If, however, the pressure on the clamping member(s) is applied by means of one or more screws engaging
either with separate nuts, or with a thread in a part which is integral with the tool, the cord anchorage is not
considered to have one part securely fixed to the tool, unless one of the clamping members itself is fixed to
the tool, or the surface of the tool is of insulating material and so shaped that it is obvious that surface is
one of the clamping member(s) (see Figure 6).
Compliance is checked by inspection, and by the test of 24.14 under the following conditions.
The tests are first made with the lightest permissible type of cord of the smallest cross-sectional area
specified in 25.2, and then with the next heavier type of cord of the largest cross-sectional area specified,
unless the tool is so designed that only one type of cord can be fitted.
Tools, for which a specially prepared cord is used, are tested with the cord as delivered.
The conductors are introduced into the terminals, the terminal screws, if any, being tightened just
sufficiently to prevent the conductors from easily changing their position. The cord anchorage is used in
the normal way, the clamping screws, if any, being tightened with a torque equal to two-thirds of that
specified in 27.1.
Screws of insulating material bearing directly on the cord are fastened with two-thirds of the torque
specified in column I of Table 9; the length of the slot in the screw head being taken as the nominal
diameter of the screw.
24.17
For type Y and Z attachments, cord anchorage shall be adequate.
Compliance is checked by the test of 24.14, which is made with the cord as delivered.
24.18
For type X attachment, production methods such as tying the cord into a knot, or tying the ends
with string, are not allowed.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Compliance is checked by inspection.

<!-- 第 91 页 -->
24.19
The insulated conductors of the supply cord shall be insulated from accessible metal parts by
insulation complying with the requirements for basic insulation for class I tools, and complying with the
requirements for supplementary insulation for class II tools. This insulation shall consist of:
– a separate insulating lining fixed to the cord anchorage;
– a sleeve or grommet fixed to the cord; or
– for class I tools, the sheath of the sheathed cord.
Compliance is checked by inspection.
24.20
The space for the supply cables or the supply cord provided inside, or as a part of the tool for type
X attachment:
– shall be so designed as to permit checking, before fitting the cover, if any, that the conductors are
correctly connected and positioned;
– shall be so designed that covers, if any, can be fitted without risk of damage to the supply
conductors or their insulation;
– shall be so designed that the uninsulated end of the conductor, should it become free from a
terminal, cannot come into contact with accessible metal parts, unless the cord is provided with
terminations that are unlikely to slip free of the conductor.
Compliance is checked by inspection and, for type X attachment, by an installation test with cables or
flexible cords of the largest cross-sectional area specified in 25.2 and by the following additional test.
For pillar terminals where the conductors are not separately clamped at a distance of 30 mm or less from
the terminal, and for other terminals with screw clamping, the clamping screws or nuts are loosened in
turn. Without removing the conductor from the conductor space, a force of 2 N is applied to the wire in any
direction and adjacent to the terminal, screw or stud. The uninsulated end of the conductor shall not then
come into contact with accessible metal parts or any other metal part connected thereto.
For pillar terminals, where the conductors are separately clamped at a distance of 30 mm or less from the
terminal, the tool is considered to meet the requirement that the uninsulated end of the conductor must not
come into contact with accessible metal parts.
24.21
Appliance inlets shall:
– be so located or enclosed that live parts are not accessible during insertion or removal of the
connector;
– be so placed that the connector can be inserted without difficulty;
– be so placed that, after insertion of the connector, the tool is not supported by the connector
when in any position of normal use on a flat surface.
Compliance is checked by inspection and, with regard to the first requirement, by means of the standard
test finger shown in Figure 1, for tool inlets other than those standardized in IEC 60320.
Tools provided with appliance inlets complying with IEC 60320 are considered to comply with the first
requirement.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 92 页 -->
Terminals for external conductors
25.1
Tools with type X attachments, except those with specially prepared cord, shall be provided with
terminals in which connection is made by means of screws, nuts, or equally effective devices. Screw type
terminals in accordance with IEC 60998-2-1, screwless terminals in accordance with IEC 60998-2-2 and
clamping units in accordance with IEC 60999-1 are considered to be equally effective devices.
Screws and nuts shall not serve to fix any other component, except that they may also clamp internal
conductors, if these are so arranged that they are unlikely to be displaced when fitting the supply
conductors.
Compliance is checked by inspection.
For tools with type X attachments, soldered connections may be used for the connection of external
conductors, provided that the conductor is so positioned or fixed that reliance is not placed upon the
soldering alone to maintain the conductor in position, unless barriers are provided so that creepage
distances and clearances between live parts and other metal parts cannot be reduced to less than 50% of
the values specified in 28.1, should the conductor become free at the soldered joint.
For type Y and type Z attachments, soldered, welded, crimped and similar connections may be used for
the connection of external conductors; moreover, for class II tools, the conductor shall be so positioned or
fixed that reliance is not placed upon the soldering, crimping, or welding alone to maintain the conductor in
position, unless barriers are provided so that creepage distances and clearances between live parts and
other metal parts cannot be reduced to less than 50% of the values specified in 28.1, should the conductor
become free at the soldered or welded joint, or slip out of the crimped connection.
It is not to be expected that two independent fixings will become loose at the same time.
Conductors connected by soldering are not considered to be adequately fixed, unless they are held in
place near to the termination, independently of the solder; but "hooking in" before soldering is, in general,
considered to be a suitable means for maintaining the conductors of a power supply cord other than a
tinsel cord in position, provided the hole through which the conductor is passed is not unduly large.
The terminals of a component (such as a switch) built into the tool may be used as terminals intended for
external conductors.
Conductors connected to terminals or terminations by other means are not considered to be adequately
fixed, unless an additional fixing is provided near the terminal or termination; this additional fixing, in the
case of stranded conductors, clamps both the insulation and the conductor.
Compliance is checked by inspection and by measurement.
25.2
Terminals for type X attachment, except those with specially prepared cords, shall allow the
connection of conductors having nominal cross-sectional areas as shown in Table 8, unless the tool is so
designed that only one type of cord can be fitted, in which case the terminals shall be suitable for the
connection of that cord.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 93 页 -->
Table 8
Nominal cross-sectional area of conductors
Rated current of tool
Nominal cross-sectional area of flexible cables and
cords
A
mm2
Up to and including 6
0,75 and 1
Over 6 up to and including 10
1 and 1,5
Over 10 up to and including 16
1,5 and 2,5
Over 16 up to and including 25
2,5 and 4
Over 25 up to and including 32
4 and 6
Over 32 up to and including 40
6 and 10
Over 40 up to and including 63
10 and 16
Compliance is checked by inspection, by measurement and by fitting cables or cords of the smallest and
largest cross-sectional areas specified.
Terminals for supply cord shall be suitable for their purpose.
Compliance is checked by inspection and by applying a pull of 5 N to the connection.
After the test, the connections shall show no damage which could impair compliance with this standard.
Table 8DV D1 Modification: Replace Table 8 with the following:
Table 8DV
Nominal cross-sectional area of conductors
Rated current of the tool
Nominal cross-sectional area
A
AWG
Up to and including 10
Over 10 up to and including 13
Over 13 up to and including 18
Over 18 up to and including 25
25.3
For tools with type X attachments, terminals shall be so fixed that, when the clamping means is
tightened or loosened, the terminal does not work loose, internal wiring is not subjected to stress, and
creepage distances and clearances are not reduced below the values specified in 28.1.
Compliance is checked by inspection, and by the test of 9.6 of IEC 60999-1, the torque applied being,
however, equal to two-thirds of the torque specified in Table 4 of that standard.
Terminals may be prevented from working loose by fixing with two screws, by fixing with one screw in a
recess, so that there is no appreciable play, or by other suitable means.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
The requirement for fixation of terminals does not preclude the provision of supply terminals on switches,
or similar device in a recess if, after connection of the supply cable, and after re-positioning of the switch or

<!-- 第 94 页 -->
similar device in its recess, it can be verified by inspection that these components and the supply cable
are, after re-assembly of the tool, in the correct position.
Covering with sealing compound without other means of locking is not considered to be sufficient. Self-
hardening resins may, however, be used to lock terminals which are not subject to torsion in normal use.
25.4
For tools with type X attachments, terminals shall be so designed that they clamp the conductor
between metal surfaces with sufficient contact pressure, and without damage to the conductor.
Compliance is checked by inspection of the terminals and of the conductors after the test of 25.3.
25.5
For tools with type X attachments, except those with specially prepared cords, terminals shall not
require special preparation of the conductor in order to effect correct connection, and they shall be so
designed or placed that the conductor cannot slip out when clamping screws or nuts are tightened.
Compliance is checked by inspection of the terminals and of the conductors after the test of 25.3.
The term "special preparation of the conductor" covers soldering of the strands, use of cable lugs,
formation of eyelets, etc., but not the reshaping of the conductor before its introduction into the terminal, or
the twisting of a stranded conductor to consolidate the end.
Conductors are considered to be damaged if they show deep or sharp indentations.
25.6
Terminals of the pillar type shall be so located that the end of a conductor introduced into the hole is
visible, or can pass beyond the threaded hole for a distance at least equal to half the nominal diameter of
the screw, or 2,5 mm, whichever is the greater.
Compliance is checked by inspection and by measurement.
25.7
For type X attachments, the terminals shall be clearly recognizable and accessible after opening the
tool. All terminals shall be located behind one cover, or one part of the enclosure.
Compliance is checked by inspection.
25.8
Terminal devices shall not be accessible without the aid of a tool, even if their live parts are not
accessible.
Compliance is checked by inspection and by manual test.
25.9
Terminal devices of tools with type X attachment shall be so located or shielded that should a wire
of a stranded conductor escape when the conductors are fitted, there is no risk of accidental connection
between live parts and accessible metal parts and, in the case of class II tools, between live parts and
metal parts separated from accessible metal parts by supplementary insulation only.
Compliance is checked by the following test:
An 8 mm length of insulation is removed from the end of a flexible conductor having a nominal cross-
sectional area as specified in 24.5.
One wire of the stranded conductor is left free, and the other wires are fully inserted into and clamped in
the terminal.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 95 页 -->
The free wire is bent, without tearing the insulation back, in every possible direction, but without making
sharp bends around barriers.
The free wire of a conductor connected to a live terminal shall not touch any metal part which is
accessible, or is connected to an accessible metal part or, for class II tools, any metal part which is
separated from accessible metal parts by supplementary insulation only. The free wire of a conductor
connected to an earthing terminal shall not touch any live part.
Provision for earthing
26.1
Accessible metal parts of class I tools, which may become live in the event of an insulation fault,
shall be permanently and reliably connected to an earthing terminal or termination within the tool, or to the
earthing contact of the tool inlet.
The printed conductors of printed circuit boards shall not be used to provide continuity of the protective
earthing circuit.
Earthing terminals and earthing contacts shall not be electrically connected to the neutral terminal.
Class II and class III tools shall have no provision for earthing.
If accessible metal parts are screened from live parts by metal parts which are connected to the earthing
terminal or termination, or to the earthing contact, they are not, for the purpose of this requirement,
regarded as likely to become live in the event of an insulation fault.
insulation, are not considered likely to become live in the event of an insulation fault.
Metal parts behind a decorative cover which does not withstand the test of clause 20 are considered to be
accessible metal parts.
Compliance is checked by inspection.
26.1DV D1 Modification: Add the following sentence to the fifth paragraph of Clause 26.1:
Rotating motor components that have metal-to-metal bearing surfaces shall be considered
to be electrically bonded to each other through the bearing surfaces for earthing purposes.
26.2
The clamping means of earthing terminals shall be adequately locked against accidental loosening,
and it shall not be possible to loosen them without the aid of a tool. Screw clamping terminals complying
with clause 25 or screwless terminals in accordance with IEC 60998-2-2 are considered to comply with the
requirements of this clause.
For specifically prepared cords, terminals complying with IEC 60760 are considered to comply with the
requirements of this clause.
Compliance is checked by inspection, by manual test and, for screwless terminals, by the tests specified in
IEC 60998-2-2.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 96 页 -->
26.2DV D1 Modification: Add the following paragraphs:
Quick-connect terminals may be used to terminate or interconnect grounding and bonding
conductors in sizes 18 – 14 AWG under the following conditions:
a) for wire sizes 18 – 16 AWG, the minimum connector and tab width shall be 2.80
mm (0.110 inch); or
b) for wire sizes 14 AWG, the minimum connector and tab width shall be 6.35 mm
(0.250 inch).
Quick-connect tabs shall not be less than 0.5 mm (0.020 inch) thick.
Multipin (friction type) insulated connectors shall not be used in equipment grounding
paths unless they are shown to be acceptable for grounding use.
26.3
If detachable parts have an earth connection, this connection shall be made before the current-
carrying connections are established when placing the part in position, and the current-carrying
connections shall be separated before the earth connection is broken when removing the part.
For tools with supply cords, the arrangement of the terminals, or the length of the conductors between the
cord anchorage and the terminals, shall be such that the current-carrying conductors become taut before
the earthing conductor, if the cord slips out of the cord anchorage.
Compliance is checked by inspection and by manual test.
26.4
All parts of the earthing terminal intended for the connection of external conductors shall be such
that there is no risk of corrosion resulting from contact between these parts and the copper of the earthing
conductor, or any other metal in contact with these parts.
Parts which may transmit current in the event of an insulation fault, other than parts of a metal frame or
enclosure, shall be of coated or uncoated metal having adequate resistance to corrosion. If such parts are
of steel, they shall be provided at the essential areas with an electroplated coating having a thickness of at
least 5 µm.
Parts of coated or uncoated metal, which are only intended to provide or to transmit contact pressure, shall
be adequately protected against rusting.
Examples of parts which may transmit current in the event of an insulation fault, and parts which are only
intended to provide or to transmit contact pressure are shown in Figure 8.
If the body of the earthing terminal is a part of a frame or enclosure of aluminium or aluminium alloy,
precautions shall be taken to avoid the risk of corrosion resulting from contact between copper and
aluminium or its alloys.
Parts of copper alloys containing at least 58% copper for parts that are worked cold, and at least 50%
copper for other parts, and parts of stainless steel containing at least 13% chrome, are considered to be
sufficiently resistant to corrosion. Parts subjected to a treatment such as chromate conversion coating are
in general not considered to be adequately protected against corrosion, but they may be used to provide
or to transmit contact pressure.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 97 页 -->
The essential areas of steel parts are, in particular, those transmitting current. In evaluating such areas,
the thickness of the coating in relation to the shape of the part has to be taken into account. In case of
doubt, the thickness of the coating is measured as described in ISO 2178 or in ISO 1463.
Compliance is checked by inspection, by measurement, by manual test and by the test of 30.1.
26.5
The connection between the earthing terminal or earthing contact, and parts required to be
connected thereto, shall be of low resistance.
Compliance is checked by the following test:
A current derived from a source having a no-load voltage not exceeding 12 V (a.c. or d.c.) and equal to 1,5
times rated current of the tool, or 25 A, whichever is the greater, is passed between the earthing terminal
or earthing contact, and each of the accessible metal parts in turn.
The voltage drop between the earthing terminal of the tool or the earthing contact of the tool inlet, and the
accessible metal part is measured, and the resistance calculated from the current and this voltage drop.
In no case shall the resistance exceed 0,1 Ω.
In case of doubt, the test is carried out until steady conditions have been established.
The resistance of the flexible cord is not included in the resistance measurement.
Care is taken that the contact resistance between the tip of the measuring probe and the metal part under
test does not influence the test results.
Screws and connections
27.1
Fixings, and electrical connections, the failure of which may impair compliance with this standard,
shall withstand the mechanical stresses occurring in normal use.
Screws used for this purpose shall not be of metal which is soft or liable to creep, such as zinc or
aluminium.
Such screws, when of insulating material, shall have a nominal diameter of at least 3 mm; they shall not be
used for any electrical connection.
Screws transmitting electrical contact pressure shall screw into metal.
Screws shall not be of insulating material if their replacement by a metal screw could impair
supplementary insulation or reinforced insulation.
Screws which may be removed when replacing a supply cord having a type X attachment, or when
undertaking user maintenance, shall not be of insulating material if their replacement by a metal screw
could impair basic insulation.
NOTE Earthing connections are an example of electrical connections.
Compliance is checked by inspection and by the following test:
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
The screws or nuts are tightened and loosened:

<!-- 第 98 页 -->
– 10 times for screws in engagement with a thread of insulating material;
– five times for nuts and other screws.
Screws in engagement with a thread of insulating material are completely removed and reinserted each
time.
When testing terminal screws and nuts, a flexible conductor of the largest cross-sectional area specified in
25.2 is placed in the terminal.
The test is made by means of a suitable test screwdriver, spanner, or key applying a torque as shown in
Table 9, the appropriate column being:
– for metal screws without heads, if the screw when tightened does not protrude
from the hole
I
– for other metal screws and for nuts
II
– for screws of insulating material:
•
having a hexagonal head with the dimension across flats exceeding the overall thread
diameter; or
•
with a cylindrical head and a socket for a key, the socket having a cross-corner dimension
exceeding the overall thread diameter; or
•
with a head having a slot or cross slots, the length of which exceeds 1,5
times the overall thread diameter
II
– for other screws of insulating material
III
Table 9
Torque for testing screws and nuts
Nominal diameter of screw
Torque
Nm
mm
I
II
III
Up to and including 2,8
0,2
0,4
0,4
Over 2,8 up to and including 3,0
0,25
0,5
0,5
Over 3,0 up to and including 3,2
0,3
0,6
0,5
Over 3,2 up to and including 3,6
0,4
0,8
0,6
Over 3,6 up to and including 4,1
0,7
1,2
0,6
Over 4,1 up to and including 4,7
0,8
1,8
0,9
Over 4,7 up to and including 5,3
0,8
2,0
1,0
Over 5,3
–
2,5
1,25
The conductor is moved each time the screw or nut is loosened.
During the test, no damage impairing the further use of the fixing or electrical connections shall occur.
The shape of the blade of the test screwdriver is to fit the head of the screw to be tested. The screws and
nuts are not to be tightened in jerks.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 99 页 -->
27.2
Electrical connections shall be so designed that contact pressure is not transmitted through
insulating material which is liable to shrink or to distort, unless there is sufficient resiliency in the metallic
parts to compensate for any possible shrinkage or distortion of the insulating material. Ceramic material is
not liable to shrink or to distort.
Compliance is checked by inspection.
27.3
Space-threaded (sheet metal) screws shall not be used for the connection of current-carrying parts,
unless they clamp these parts directly in contact with each other, and are provided with a suitable means
of locking.
Thread-cutting (self-tapping) screws shall not be used for the electrical connection of current-carrying
parts, unless they generate a full-form standard machine screw thread. Such screws shall not, however,
be used if they are likely to be operated by the user or installer, unless the thread is formed by a swageing
action.
Thread-cutting and space-threaded screws may be used to provide earthing continuity, provided that it is
not necessary to disturb the connection in normal use, and that at least two screws are used for each
connection.
Compliance is checked by inspection.
27.3DV DR Modification:
Delete the phrase "and space-threaded" from the third paragraph.
27.4
Screws, which make a mechanical connection between different parts of the tool, shall be secured
against loosening, if they also make electrical connections.
This requirement does not apply to screws in the earthing circuit if at least two screws are used for the
connection, or if an alternative earthing circuit is provided.
Spring washers and the like may provide satisfactory security. Sealing compound which softens on
heating provides satisfactory security only for screw connections not subject to torsion in normal use.
Rivets used for electrical connections shall be secured against loosening if these connections are subject
to torsion in normal use. A non-circular shank or an appropriate notch may be sufficient to comply with this
requirement.
This requirement does not imply that more than one rivet is necessary for providing earthing continuity.
Compliance is checked by inspection and by manual test.
Creepage distances, clearances and distances through insulation
28.1
Creepage distances and clearances shall not be less than the values in millimetres shown in Table
10. The values specified in the table do not apply to cross-over points of motor windings.
If a resonance voltage occurs between the point where a winding and a capacitor are connected together,
and metal parts which are separated from live parts by basic insulation only, the creepage distance and
resonance, these values being increased by 4 mm in the case of reinforced insulation.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 100 页 -->
Compliance is checked by measurement.
For tools provided with an appliance inlet, the measurements are made with an appropriate connector
inserted; for tools with type X attachment, they are made with supply conductors of the largest cross-
sectional area specified in 25.2, and also without conductors; for other tools, they are made on the tool as
delivered.
For tools provided with belts, the measurements are made with the belts in place, and the devices
intended for varying the belt tension adjusted to the most unfavourable position within their range of
adjustment, and also with the belts removed.
Movable parts are placed in the most unfavourable position; nuts and screws with non-circular heads are
assumed to be tightened in the most unfavourable position.
The clearances between terminals and accessible metal parts are also measured with the screws or nuts
unscrewed as far as possible, but the clearances shall then be not less than 50% of the value shown in
Table 10.
Distances through slots or openings in external parts of insulating material are measured to metal foil in
contact with the accessible surface; the foil is pushed into corners and the like by means of the standard
test finger of Figure 1, but it is not pressed into openings.
If necessary, a force is applied to any point on bare conductors, other than those of heating elements, to
any point on uninsulated metal capillary tubes of thermostats and similar devices, and to the outside of
metal enclosures, in an endeavour to reduce the creepage distances and clearances while taking the
measurements.
Table 10
Minimum creepage distances and clearances
Distances
Class III tools
Creepage
Clearance
Creepage
distance
distance
mm
Between live parts of different
polarity a:
– if protected against
deposition of dirt b
1,0
1,0
1,0
1,0
2,0
2,0
2,0
2,0
– if not protected against
deposition of dirt
– if lacquered or enamelled
windings
– for positive temperature
coefficient (PTC) resistors
including their connecting
wires, if protected against
deposition of moisture or dirt b
Between live parts and other
metal parts over basic
insulation:
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Table 10 Continued on Next Page
DISTRIBUTION WITHOUT PERMISSION FROM UL
Dimensions in millimetres
Other tools
Working voltage
Working voltage
Working voltage
≤130 V
>130 V and ≤250 V
>250 V and ≤440 V
Clearance
Creepage
Clearance
Creepage
Clearance
distance
distance
2,0
1,5
2,0
1,5
3,0
2,5
4,0
3,0
1,0
1,0
1,5
1,5
2,0
2,0
3,0
3,0
–
–
1,0
1,0
1,0
1,0
–
–

<!-- 第 101 页 -->
Table 10 Continued
Distances
Class III tools
Creepage
Clearance
Creepage
distance
distance
mm
– if protected against
deposition of dirt b
• if of ceramic material, pure
mica and the like
• if of other material
1,5
1,0
1,5
1,0
3,0
2,5 c
–
–
– if not protected against
deposition of dirt
– if the live parts are lacquered
or enamelled windings
– at the end of tubular
sheathed-type heating
elements
Between live parts and other
metal parts over reinforced
insulation:
– if the live parts are lacquered
or enamelled windings or
protected against deposition of
dirt
– for other live parts not
protected against deposition of
dirt
Between metal parts separated
by supplementary insulation
a The clearances specified do not apply to the air gap between the contacts of thermal controls, overload protection devices,
switches of micro-gap construction, and the like, or to the air gap between the current-carrying members of such devices where the
clearance varies with the movement of the contacts.
b In general, the interior of a tool having a reasonably dust-proof enclosure is considered to be protected against deposition of dirt;
provided the tool does not generate dust within itself; hermetic sealing is not required.
c If the parts are rigid and located by mouldings, or if the design is such that there is no likelihood of a distance being reduced by
distortion or movement of the parts, this value may be reduced to 2,0 mm.
d If protected against deposition of dirt.
e If over ceramic, pure mica and the like, protected against deposition of dirt.
The force is applied by means of the test finger of Figure 1, and has a value of:
– 30 N for enclosures.
The way in which creepage distances and clearances are measured is indicated in Annex A.
If a barrier is interposed, and if it is in two parts which are not cemented together, the creepage distance is
also measured through the joint.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
If a barrier is interposed, clearances are measured over the barrier or, if the barrier is in two parts with
mating surfaces which are not cemented together, through the joint.
DISTRIBUTION WITHOUT PERMISSION FROM UL
Dimensions in millimetres
Other tools
Working voltage
Working voltage
Working voltage
≤130 V
>130 V and ≤250 V
>250 V and ≤440 V
Clearance
Creepage
Clearance
Creepage
Clearance
distance
distance
1,0
1,0
1,0
1,0
2,5 c
2,5 c
–
–
2,0
1,5
2,0
1,5
4,0
3,0
–
–
1,0
1,0
1,5
1,5
2,0
2,0
–
–
–
–
1,0
1,0
1,0 e
1,0 d
–
–
–
–
5,0
5,0
6,0
6,0
–
–
–
–
8,0
5,0
8,0
8,0
–
–
–
–
2,5
2,5
4,0
4,0
–
–
– 2 N for bare conductors and for uninsulated capillary tubes of thermostats and similar devices;

<!-- 第 102 页 -->
For tools having parts with double insulation where there is no metal between basic insulation and
supplementary insulation, the measurements are made as though a metal foil were present between the
two insulations.
When assessing creepage distances and clearances, the effect of insulating lining of metal enclosures or
covers is taken into consideration.
Means provided for fixing the tool to a support are considered to be accessible.
For conductive patterns on printed circuit boards, except at their edges, the values in the table between
parts of different potential may be reduced, as long as the peak value of the voltage stress does not
exceed:
– 150 V per mm with a minimum distance of 0,2 mm, if protected against the deposition of dirt;
– 100 V per mm with a minimum distance of 0,5 mm, if not protected against the deposition of dirt.
When the limits mentioned above lead to higher values than those of the table, the values of the table
apply.
For peak voltages exceeding 50 V, the reduced creepage distances only apply if the Proof Tracking Index
(PTI) of the printed circuit board, measured as in Annex G, is greater than 175.
These distances may be reduced further, provided that the tool complies with the requirements of clause
18 when the distances are short-circuited in turn.
Creepage distances and clearances within optocouplers are not measured if the individual insulations are
adequately sealed, and if air is excluded between individual layers of the material.
For live parts of different polarity separated by basic insulation only, creepage distances and clearances
smaller than those specified in the table are allowed, provided the requirements of clause 18 are met if
these creepage distances and clearances are short-circuited in turn.
28.2
For working voltages up to and including 130 V, the distance through insulation between metal parts
shall not be less than 1,0 mm, if they are separated by supplementary insulation, and not be less than 1,5
mm, if they are separated by reinforced insulation. For reinforced insulation used between windings and
accessible metal, the distance through the insulation shall not be less than 1,0 mm.
For working voltages over 130 V up to and including 250 V, the distance through insulation between metal
parts shall not be less than 1,0 mm, if they are separated by supplementary insulation, and not be less
than 2,0 mm, if they are separated by reinforced insulation.
This requirement does not apply if the insulation is applied in thin sheet form, other than mica or similar
scaly material, and consists:
– for supplementary insulation, of at least two layers, provided that any one of the layers withstands
the electric strength test prescribed for supplementary insulation;
– for reinforced insulation, of at least three layers, provided that, when any two of the layers are
placed in contact, they withstand the electric strength test prescribed for reinforced insulation.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
The test voltage is applied between the outer surfaces of the layer, or of the two layers, as applicable.

<!-- 第 103 页 -->
Moreover, this requirement does not apply if the supplementary insulation or the reinforced insulation is
inaccessible, and meets one of the following conditions:
– the maximum temperature rise determined during the tests of clause 12 does not exceed the
permissible value specified in 12.5;
– the insulation, after having been conditioned for seven days (168 h) in a oven maintained at a
temperature equal to 50 K greater than the maximum temperature rise determined during the tests
of clause 12, withstands an electric strength test as specified in clause 15, this test being made on
the insulation both at the temperature occurring in the oven, and at approximately room
temperature.
This requirement does not imply that the prescribed distance must be through solid insulation only; it may
consist of thickness of solid insulation plus one or more air layers.
Compliance is checked by inspection and by measurement.
For optocouplers, the conditioning procedure is carried out at a temperature of 50 K in excess of the
maximum temperature rise measured on the optocoupler during the tests of clause 12 and clause 18, the
optocoupler being operated under the most onerous conditions which occur during these tests.
Resistance to heat, fire and tracking
NOTE Annex J shows the selection and sequence of the tests of this clause.
29.1
External parts of non-metallic material, parts of insulating material supporting live parts, including
connections and parts of thermoplastic material providing supplementary insulation or reinforced
insulation, the deterioration of which might cause the tool to fail to comply with this standard, shall be
sufficiently resistant to heat.
of the apparatus shown in Figure 5.
Before starting the test, the part is maintained for 24 h in an atmosphere having a temperature between
15 °C and 35 °C, and a relative humidity between 45% and 75%.
The part is supported so that its upper surface is horizontal and the spherical part of the apparatus is
pressed against this surface with a force of 20 N. The thickness of the part under test shall be at least 2,5
mm.
The required thickness may be obtained by using two or more sections of the part.
The test is made in a heating cabinet at a temperature of (40 ±2) °C plus the maximum temperature rise
determined during the test of clause 12, but it shall be at least:
– for external parts (75 ±2) °C;
– for parts retaining live parts in position (125 ±2) °C.
Before the test is started, the test apparatus is brought to the temperature determined above.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
After 1 h, the apparatus is removed and the part is immediately immersed in cold water so that it is cooled
to room temperature within 10 s. The diameter of the impression shall not exceed 2 mm.

<!-- 第 104 页 -->
For coil formers, only those parts which support or retain in position terminals or terminations are
subjected to the test.
Unless otherwise specified, parts operating at safety extra-low voltage not exceeding 24 V are not
considered to be live parts.
The test is not made on parts of ceramic material.
29.1DV D1 Modification: Replace the last paragraph with the following:
The tests are not made on parts of ceramic material, insulating parts of motors, such as
shaft insulation, end spiders, wedges, or commutators unless otherwise specified in the
Part 2.
29.2
Parts of non-metallic material shall be adequately resistant to ignition and to spread of fire.
This requirement does not apply to decorative trims, knobs, and other parts not likely to be ignited or to
propagate flames originating from inside the tool.
Compliance is checked by subjecting parts of non-metallic material to the glow-wire test of IEC 60695-2-
11, which is carried out at 550 °C.
The glow-wire test is not carried out on parts of material classified at least HB40 according to IEC 60695-
11-10, provided that the test sample was no thicker than the relevant part.
Parts for which the glow-wire test cannot be carried out, such as those made of soft or foamy material,
shall meet the requirements specified in ISO 9772 for category HBF material, the test sample being no
thicker than the relevant part.
29.2DV D2 Modification: Replace Clause 29.2 with the following:
Parts of non-metallic material shall be adequately resistant to ignition and spread of fire.
This requirement does not apply to:
– internal parts that are more than 13,0 mm from an arcing part such as a
commutator, unenclosed switch contacts, and the like;
– internal parts that are more than 1,0 mm from a non-arcing uninsulated live part,
such as a busbar, a connecting strap, a terminal, enamelled wire, and the like;
– the insulation of wires;
– the base material of printed circuit boards;
– gears, cams, belts, bearings, fans, decorative trims, and knobs that would
contribute negligible fuel to fire;
– ceramic materials;
– the following insulating parts of motors: shaft insulation, end spiders, wedges,
and commutators.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Compliance is checked by one of the following:

<!-- 第 105 页 -->
– subjecting parts of non-metallic material to the glow-wire test of IEC 60695-2-11,
which is carried out at 550 °C;
– the material is being classified at least HB40 according to IEC 60695-11-10
provided that the test sample was no thicker than the relevant part;
– the material having a glow wire ignition temperature of at least 575 °C according to
IEC 60695-2-13 provided that the test sample was no thicker than the relevant part.
Parts for which the above cannot be carried out, such as those made of soft or foamy
material, shall meet the requirements specified in ISO 9772 for category HBF material, the
test sample being no thicker than the relevant part.
29.3
Insulating material, across which a tracking path may occur, shall have adequate resistance to
tracking, taking into account the severity of its duty conditions.
A tracking current may occur
– between live parts of different polarity;
– between live parts and earthed metal parts;
– across insulating material of commutators and brush-caps.
All tools are considered to be normal duty unless stated in the relevant part 2.
For parts of insulating material used under severe or extra-severe duty conditions, compliance is checked
by the proof tracking test referred to in Annex G.
For parts of insulating material used under normal duty conditions, and parts of ceramic material, no
tracking test is made.
For parts of insulating material used under severe duty conditions, the test voltage is 175 V. If the
specimens do not withstand this test and there is no hazard other than fire, surrounding parts are
subjected to the needle-flame test referred to in Annex F.
For parts of insulating material used under extra-severe duty conditions, the test voltage is 250 V. If the
specimens do not withstand this test, but withstand the test made with a test voltage of 175 V, and there is
no hazard other than fire, surrounding parts are subjected to the needle-flame test referred to in Annex F.
The needle-flame test is made on all parts of non-metallic material positioned within a distance of 50 mm
from any place where a tracking path may occur, unless these parts are shielded by a separate barrier or
enclosure from that tracking path, in which case the barrier or enclosure is subjected to the needle-flame
test.
Resistance to rusting
30.1
Ferrous parts, the rusting of which might cause the tool to fail to comply with this standard, shall be
adequately protected against rusting.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Compliance is checked by the following test:

<!-- 第 106 页 -->
All grease is removed from the parts to be tested by immersing them in a suitable degreasing agent for 10
min.
The parts are then immersed for 10 min in a 10% solution of ammonium chloride in water at a temperature
of (20 ± 5) °C.
Without drying, but after shaking off any drops, the parts are placed for 10 min in a box containing air
saturated with moisture at a temperature of (20 ± 5) °C.
After the parts have been dried for 10 min in a heating cabinet at a temperature of (100 ± 5) °C, their
surfaces shall show no signs of rust.
When using the liquids specified for the test, adequate precautions must be taken to prevent the inhalation
of their vapours.
Traces of rust on sharp edges and any yellowish film removable by rubbing are ignored.
For small helical springs and the like, and for parts exposed to abrasion, a layer of grease may provide
sufficient protection against rusting. Such parts are only subjected to the test if there is doubt about the
effectiveness of the grease film, and the test is then made without previous removal of the grease.
Radiation, toxicity and similar hazards
31.1
Tools shall not emit harmful radiation, or present a toxic or similar hazard.
Compliance is checked by test.
NOTE Test specifications are given in part 2, where necessary.
31.2
If the tool is fitted with a laser to indicate a cutting line or the like, the laser shall be of category II or
lower, according to IEC 60825-1.
Compliance is checked by inspection.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 107 页 -->
Figure 1
Standard test finger
Material: metal, except where otherwise specified
Linear dimensions in millimetres
Key
Tolerances on dimensions without specific tolerance:
A Handle
F Chamfer all edges
on angles: 0/-10°
B Guard
G Spherical
on linear dimensions:
C Insulating material
H Cylindrical
up to 25 mm: 0/-0,05
D Joints
over 25 mm: ±0,2
E Stop face
Both joints shall permit movement in the same plane and the same direction through an angle of 90° with a 0° to +10°
tolerance.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 108 页 -->
Figure 2
Test pin
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 109 页 -->
Key
C Circuit of Figure 10 for the leakage current meter
S Mains switch of the product under test
1 Accessible part
2 Inaccessible metal part
3 Basic insulation
4 Supplementary insulation
5 Reinforced insulation
6 Double insulation
APRIL 30, 2020
CAN/CSA-C22.2 No. 60745-1-07 ♦UL 60745-1
Figure 3
Diagram for leakage current measurement at operating temperature for single-phase connection
and three-phase tools suitable for single-phase supply
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 110 页 -->
Key
C Circuit of Figure 10 for the leakage current meter
1 Accessible part
2 Inaccessible metal part
3 Basic insulation
4 Supplementary insulation
5 Three-phase supply
6 Double insulation
CAN/CSA-C22.2 No. 60745-1-07 ♦UL 60745-1
APRIL 30, 2020
Figure 4
Diagram for leakage current measurement at operating temperature for three-phase connection
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 111 页 -->
Key
A Spherical
B Sample
APRIL 30, 2020
CAN/CSA-C22.2 No. 60745-1-07 ♦UL 60745-1
Figure 5
Ball-pressure test apparatus
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 112 页 -->
Figure 6
Schematic representation of cord anchorages
Part of tool of insulating
material and so-shaped
that it obviously forms
part of a cord clamp
Acceptable constructions
(Figure 6 Continued)
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
DISTRIBUTION WITHOUT PERMISSION FROM UL
One of the clamping
measures is fixed to the
tool

<!-- 第 113 页 -->
Screws passing through threaded holes in the tool (or screws passing through clearance holes in the tool and secured by nuts) are
equally unacceptable
Unacceptable constructions
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 114 页 -->
Key
A Insulating material
B Spring diameter
C Loop
CAN/CSA-C22.2 No. 60745-1-07 ♦UL 60745-1
APRIL 30, 2020
Figure 7
Test fingernail
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 115 页 -->
Figure 8
Examples of parts of earthing terminals
Key
A Part providing earthing continuity
B Part providing or transmitting contact pressure
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 116 页 -->
Key
A Axis of oscillation
B Oscillating frame
C Counterweight
D Sample
E Adjustable carrier plate
F Adjustable bracket
G Load
CAN/CSA-C22.2 No. 60745-1-07 ♦UL 60745-1
APRIL 30, 2020
Figure 9
Flexing test apparatus
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 117 页 -->
Figure 10
Circuit for measuring leakage currents
Figure 11
Example of an electronic circuit with low-power points
A and B are points closest to the supply source where the maximum power delivered to external load does not exceed 15 W. These
are low-power points.
D is a point farthest from the supply source where the maximum power delivered to external load exceeds 15 W.
Points A and B are separately short-circuited to C.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
The fault conditions a) to f) specified in 18.10.2 are applied individually to Z1, Z2, Z3, Z6 and Z7 where applicable.

<!-- 第 118 页 -->
Annex A
(normative)
Measurement of creepage distances and clearances
A.1
Measurement of creepage distances and clearances
The methods of measuring creepage distances and clearances, which are specified in 28.1, are indicated
in cases 1 to 10 (see Figure A.1).
These cases do not differentiate between gaps and grooves, or between types of insulation.
The following assumptions are made:
– a groove may have parallel, converging, or diverging sides;
– any groove having diverging sides, a minimum width exceeding 0,25 mm, a depth exceeding 1,5 mm,
and a width at the bottom equal to or greater than 1 mm, is regarded as an air gap across which no
creepage path exists (case 8);
– any corner including an angle less than 80° is assumed to be bridged with an insulating link of 1 mm
width (0,25 mm for dirt-free situations), moved into the most unfavourable position (case 3);
– where the distance over the top of a groove is 1 mm (0,25 mm for dirt-free situations) or more, no
creepage distance exists across the air gap (case 2);
– creepage distances and clearances measured between parts moving relative to each other are
measured when these parts are placed in their most unfavourable stationary positions;
– any air gap less than 1 mm wide (0,25 mm for dirt-free situations) is ignored in computing the total
clearance.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 119 页 -->
Figure A.1a
Clearance gap for parallel sided and V-shaped groove
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 120 页 -->
Figure A.1b
Clearance gap for rib and uncemented joint with groove
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 121 页 -->
Figure A.1c
Clearance gap for uncemented joint and diverging-sided groove
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 122 页 -->
Figure A.1d
Clearance gap between wall and screw
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 123 页 -->
Annex B
(normative)
Motors not isolated from the supply mains and having basic insulation not designed for the rated
voltage of the tool
B.1
Scope
B.1.1
This annex applies to motors having a working voltage not exceeding 42 V, not isolated from the
supply mains, and having basic insulation not designed for the rated voltage of the tool.
All clauses of this standard apply to these motors, unless otherwise specified in this annex.
B.9
Protection against access to live parts
B.9.1
Metal parts of the motor are considered to be bare live parts.
B.12
Heating
B.12.3
The temperature rise of the body of the motor is determined instead of the temperature rise of the
windings.
B.12.5
The temperature rise of the body of the motor, where it is in contact with insulating material, shall
not exceed the values shown in Table 1 for the relevant insulating material.
B.15
Electric strength
B.15.3
The insulation between live parts of the motor and its other metal parts is not subjected to this
test.
B.18
Abnormal operation
B.18.1
The test of 18.7 is not made.
Tools are also subjected to the test of B.18.201.
B.18.201
The tool is operated at rated voltage with each of the following defects:
– short circuit of the terminals of the motor, including any capacitor incorporated in the motor circuit;
– open circuit of the supply to the motor;
– open circuit of any shunt resistor during operation of the motor.
Only one defect is simulated at a time, the tests being made consecutively.
B.21
Construction
B.21.201
For class I tools incorporating a motor supplied by a rectifier circuit, the d.c. circuit shall be
insulated from accessible parts of the tool by double insulation or reinforced insulation.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Compliance is checked by the tests specified for double insulation and reinforced insulation.

<!-- 第 124 页 -->
Components
— original connection
- – - short circuit
≈open circuit
A short circuit of the terminals of the motor
B short circuit of the terminals of the rectifier
C open circuit of the supply to the motor
D open circuit of the shunt resistor
CAN/CSA-C22.2 No. 60745-1-07 ♦UL 60745-1
APRIL 30, 2020
B.28
Creepage distances, clearances and distances through insulation
B.28.1
The values specified in Table 10 do not apply to distances between live parts of the motor and its
other metal parts.
Figure B.1
Simulation of defects
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 125 页 -->
Annex C
Void
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 126 页 -->
Annex D
Void
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 127 页 -->
Annex E
Void
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 128 页 -->
Annex F
(normative)
Needle-flame test
The needle-flame test is made in accordance with IEC 60695-11-5.
For the purpose of this standard, the following modifications to clauses and subclauses of IEC 60695-11-5
apply.
Description of the test apparatus
5.4
Specified layer
In cases where burning or glowing particles might fall from the specimen onto an external surface
underneath the tool, the test is made with a piece of white pine-wood board, approximately 10 mm thick,
and covered with a single layer of tissue paper, positioned at a distance of 200 mm ±5 mm below the place
where the test flame is applied to the specimen. If the tool as a whole is tested, it is placed in its normal
position of use above the pine-wood board, which is covered with a single layer of tissue paper.
Severities
The duration of application of the test flame is 30 s.
Test procedure
9.3
Number of test specimens
The test is made on one specimen. If the specimen does not withstand the test, the test is repeated on two
further specimens, both of which shall then withstand the test.
Evaluation of test results
Add:
When a layer of tissue paper is used, there shall be no ignition of the tissue paper, or scorching of the
white pine-wood board; a slight discoloration of the white pine-wood board being neglected.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 129 页 -->
Annex G
(normative)
Proof tracking test
The proof tracking test is made in accordance with IEC 60112.
For the purpose of this standard, the following modifications to clauses and subclauses of IEC 60112
apply.
Test specimen
The second paragraph, after NOTE 2, does not apply.
Test apparatus
The test solution A described in 7.3 is used.
Basic test procedure
The test voltage referred to in 8.2 is adjusted to 175 V or 250 V, as appropriate.
Determination of erosion
This clause does not apply.
Determination of proof tracking index (PTI)
The number of specimens is five.
Determination of comparative tracking index (CTI)
This clause does not apply.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 130 页 -->
Annex H
Void
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 131 页 -->
Annex I
(normative)
Switches
Switches which are tested with the tool shall comply with this standard and with the following clauses of
IEC 61058-1, as modified.
Unless otherwise specified, the tests are carried out on the switch incorporated in the tool. Before being
tested in the tool, switches are operated 20 times without load.
Marking and documentation
Switches are not required to be marked, except that incorporated switches shall be marked with the
manufacturer's name or trade mark and the type reference.
NOTE According to IEC 61058-1, an incorporated switch can be tested separately from the tool.
Mechanism
This clause is applicable.
NOTE The tests may be carried out on a separate sample.
Insulation resistance and dielectric strength
15.1
The dielectric strength of switches shall be adequate.
Compliance is checked by the test of 15.3, the test being made immediately after the test of 14.3 of IEC
60745.
For mechanical switches, the test is carried out across full disconnection and micro-disconnection only.
For electronic switches, the test is carried out across full disconnection and micro-disconnection only on
electronic switches with mechanical switching devices connected in series with the semiconductor
switching device.
For electronic switches, the tests are not carried out across protective impedances and poles
interconnected by components.
15.2
This subclause is not applicable.
Endurance
17.1.1
Addition:
Switches in the tool are considered to be for declared specific loads.
17.1.2
The sequence of tests for all switches except electronic switches is as follows:
– a test at accelerated speed as specified in 17.2.4.4;
– a temperature-rise test in accordance with 16.2, with the exception that the temperature-rise test
at the terminals is carried out at rated current and in an ambient temperature of 25°C ±10°C;
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 132 页 -->
– a dielectric strength test in accordance with 15.3, with the exception that the specimens are not
subjected to the humidity treatment before the application of the test voltage. The test voltage shall
be 75% of the corresponding test voltage specified in that subclause.
17.2.1.1
The switch shall be loaded at rated voltage under the conditions occurring in the tool.
Circuits and contacts which are not intended for external loads are operated with the designated load.
No electrical endurance tests are necessary for switches for 20 mA load as classified in 7.1.2.6.
NOTE For a specific lamp load, it is recommended that the specimen be operated with loads that are used in the field rather
than with synthetic loads. Forced cooling of the specific lamp load may be applied in order to ensure cold resistance for
each operating cycle and shorten the test time.
For electronic switches, the test circuit shall be as shown in Figure 19. The declared load shall be set at
rated voltage before the electronic switch is inserted into the circuit.
17.2.1.2
This subclause is not applicable.
17.2.2.1
All tests are carried out at 25°C ±10°C.
17.2.3.1
Items a) and b) are not applicable.
17.2.3.3
This subclause is not applicable.
17.2.3.4.2
This subclause is not applicable.
17.2.3.4.3
This subclause is not applicable.
17.2.4.1
This subclause is not applicable.
17.2.4.2
This subclause is not applicable.
17.2.4.3
This subclause is not applicable.
17.2.4.4
Test at accelerated speed (TC4)
For all switches except electronic switches, the electrical conditions are those specified in 17.2.1.
For electronic switches, the electrical conditions are those specified in Table 15.
The thermal conditions are those specified in 17.2.2.
The total number of operations shall be 50 000.
The method of operation is that specified for accelerated speed in 17.2.3.
17.2.4.9
This subclause is not applicable.
Clearances, creepage distances, solid insulation and coatings of rigid printed board
assemblies
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This clause is applicable for creepage distances and clearances for live parts of different potential only, for
operational insulation and across full disconnection and micro-disconnection.

<!-- 第 133 页 -->
Annex J
(informative)
Selection and sequence of the tests of clause 29
Resistance to heat and fire
Tools
Parts of
insulating
material
supporting live
External parts
of non-metallic
parts,
including
connections
material
Ball pressure
Ball pressure
test
≥75 °C
test
≥125 °C
(29.1)
(29.1)
Glow-wire test
550 °C
IEC 60695-2-
(29.2)
Resistance to tracking
Tools
Normal duty
Severe duty
conditions
conditions
Tracking test 175 V
No tracking test
Annex G
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
DISTRIBUTION WITHOUT PERMISSION FROM UL
Thermoplastic
material
providing
supplementa-
ry or
reinforced
Other parts of
non-metallic
insulation
material
Ball pressure
Ball pressure
test
ΔTmax + 40 K
test
No
requirements
(29.1)
Extra severe duty
conditions
Tracking test
250 V
Annex G
Failure
Failure
Tracking test 175 V
Annex G
Pass
Needle-flame test on surrounding
parts
Annex F

<!-- 第 134 页 -->
Annex K
(normative)
Battery tools and battery packs
K.1
Scope
This annex applies to rechargeable battery-powered motor-operated or magnetically driven tools and the
battery packs for such tools. This annex applies to tools incorporating detachable, integral and separable
battery packs. The maximum rated voltage for tools and battery packs is 75 V d.c.
Battery tools covered by this annex are not considered to be class I, class II, or class III tools and therefore
are not required to have basic, supplementary or reinforced insulation. Electric shock hazard is considered
to exist only between parts of opposite polarity.
Battery packs for tools covered under this annex intended to be charged by a non-isolated charger shall
be evaluated by this annex and standard. When evaluating a battery pack for protection against electric
shock, creepage distances, clearances and distances through insulation, the battery pack shall be fitted to
the intended charger.
All clauses of this standard apply unless otherwise specified in this annex. If a clause is stated in the
annex, the requirements replace the requirements of the standard.
For the purpose of the tools covered by this annex, the term "mains switch" as it appears in the standard is
understood to refer to the power switch of the battery-operated tool.
This annex is not intended to apply to tools using general purpose batteries installed by the user and this
annex alone will not be sufficient to ensure all hazards are considered for these products' “battery packs”.
This annex does not apply to battery chargers which are covered by IEC 60335-2-29.
K.2
Normative references
This clause is applicable except as follows:
Additional normative reference:
IEC 61558-2-6:1997, Safety of power transformers, power supply units and similar – Part 2: Particular
requirements for safety isolating transformers for general use
K.3
Terms and Definitions
For the purpose of this annex, the following definitions apply.
K.3.201
battery pack: assembly of one or more cells intended to provide electrical current to the tool
K.3.201.1
detachable battery pack: battery pack which is contained in a separate enclosure from the
battery tool and is intended to be removed from the tool for charging purposes
K.3.201.2
integral battery pack: battery pack which is contained within the battery tool and is not
removed from the battery tool for charging purposes. A battery pack that is to be removed from the battery
tool for disposal or recycling purposes only is considered to be an integral battery pack
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
K.3.201.3
separable battery pack: battery pack which is contained in a separate enclosure from the
battery tool and is connected to the battery tool by a cord

<!-- 第 135 页 -->
K.3.202
fully charged battery pack: battery pack which has been through at least two discharge and
charge cycles with an interval of at least two hours after each cycle in accordance with the manufacturer's
instructions
K.3.203
non-isolated source: voltage source in which the output is not isolated from the mains supply
by means of a safety isolating transformer as specified in IEC 61558-1 and IEC 61558-2-6
K.3.204
hazardous voltage: voltage between parts having an average value exceeding 60 V d.c. or
42,4 V peak when the peak to peak ripple exceeds 10% of the average value
K.3.205
power switch: power switch that controls the primary operating means of the tool
K.5
General conditions for the tests
K.5.7.1
This subclause is not applicable.
K.5.7.2
Tools having more than one rated voltage are tested on the basis of the most unfavourable
voltage.
K.5.7.3
This subclause is not applicable.
K.5.10
This subclause is not applicable.
K.5.11
This subclause is not applicable.
K.5.14
This subclause is not applicable.
K.5.15
This subclause is not applicable.
K.5.16
This subclause is not applicable.
K.5.201
Unless otherwise specified, a fully charged battery pack shall be used for each test.
K.5.202
When measuring voltage, the peak value of any superimposed ripple exceeding 10% of the
average value shall be included. Transient voltages are ignored, such as a temporary increase above
rated voltage, for example after the battery pack is removed from the charger.
K.7
Classification
This clause is not applicable.
K.8
Marking and instructions
K.8.1
Battery tools and detachable or separable battery packs shall be marked with:
– rated voltage(s) or rated voltage range(s), in volts;
– symbol for nature of supply;
– name or trade mark or identification mark of the manufacturer or responsible vendor;
– model or type reference;
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
– manufacturer's address or country of origin;
– any mandatory mark showing compliance with legislation by reference to this standard.

<!-- 第 136 页 -->
Additional markings shall not give rise to misunderstanding.
Compliance is checked by inspection.
K.8.1DV D1 Modification: Add the following after the last dashed item:
– "WARNING – To reduce the risk of injury, user must read instruction manual" or
the sign M002 of ISO 7010.
If used, the word "WARNING" shall be in capital letters not less than 2,4 mm high and shall
not be separated from the cautionary statement.
If used, the statement shall be verbatim except the term "operator’s manual" or "user
guide" may be used for the term "instruction manual".
K.8.2
This subclause is not applicable.
K.8.5
This subclause is not applicable.
K.8.7
This subclause is not applicable.
K.8.8
This subclause is not applicable.
K.8.12.1.1
This subclause is applicable except as follows:
Item 5) Service, is replaced by the following:
5) Battery tool use and care
a) Recharge only with the charger specified by the manufacturer. A charger that is suitable for
one type of battery pack may create a risk of fire when used with another battery pack.
b) Use power tools only with specifically designated battery packs. Use of any other battery
packs may create a risk of injury and fire.
c) When battery pack is not in use, keep it away from other metal objects, like paper clips,
coins, keys, nails, screws or other small metal objects, that can make a connection from
one terminal to another. Shorting the battery terminals together may cause burns or a fire.
d) Under abusive conditions, liquid may be ejected from the battery; avoid contact. If
contact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek
medical help. Liquid ejected from the battery may cause irritation or burns.
6) Service
a) Have your power tool serviced by a qualified repair person using only identical
replacement parts. This will ensure that the safety of the power tool is maintained.
K.8.12.1.1DV D2 Modification: Add the following paragraph to Clause K.8.12.1.1:
Clauses 8.12.1.1, 8.12.1.2, 8.12.2 (first paragraph and associated warnings only) may be
replaced in their entirety with Clauses 8.14.1.1, 8.14.1.2, and 8.14.1.3 of UL 62841-1 or
CAN/CSA C22.2 No. 62841-1. Partial substitution of the above-mentioned set of clauses
between standards is not permitted.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 137 页 -->
K.9
Protection against electric shock
NOTE The title of this clause differs from that of the main standard.
Battery tools and battery packs shall be so constructed and enclosed that there is adequate protection against electric
shock.
K.9.1
This subclause is not applicable.
K.9.2
It shall not be possible to have two conductive, simultaneously accessible parts where the voltage
between them is hazardous unless they are provided with protective impedance.
In the case of protective impedance the short circuit current between the parts shall not exceed 2 mA for d.
c. or 0,7 mA peak for a.c. and there shall not be more than 0,1 µF capacitance directly between the parts.
Compliance for accessibility is checked by applying the test finger of Figure 1 to each conductive part.
The test finger of Figure 1 is applied without any appreciable force through openings to any depth that the
finger will permit, and it is rotated or angled before, during and after insertion to any position.
If the opening does not allow entry of the finger, the force on the finger in the straight position is increased
to 20 N and the test with the finger bent repeated.
Contact with the test finger is determined with all detachable parts removed and the battery tool operated
in any possible position of normal use.
Lamps located behind detachable covers are not removed, providing the lamp may be de-energized by
means of a user operable plug, battery pack disconnection or a switch.
K.9.3
This subclause is not applicable.
K.9.4
This subclause is not applicable.
K.10
Starting
This clause is not applicable.
K.11
Input and current
This clause is not applicable.
K.12
Heating
K.12.1
Battery tools and battery packs shall not attain excessive temperatures.
Compliance is checked by determining the temperature rise of the various parts under the following
conditions:
The tool is operated at no-load until maximum temperature is reached or the tool no longer operates due
to the battery pack being discharged.
During the test, thermal cut-outs and overload releases shall not operate. The temperature rises shall not
exceed the values shown in Table K.1.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 138 页 -->
Table K.1
Maximum normal temperature rises for battery tools
Parts
Temperature rise K
External enclosure, except handles held in normal use
Handles, knobs, grips, and the like which, in normal use, are continuously held:
– of metal
– of porcelain or vitreous material
– of molded material, rubber or wood
Handles, knobs, grips, and the like which, in normal use, are held for short
periods only (e.g. switches):
– of metal
– of porcelain or vitreous material
– of molded material, rubber or wood
Parts in contact with oil having a flash point of t° C
t-50
K.12.2 to K.12.6 These subclauses are not applicable.
K.13
Leakage current
This clause is not applicable.
K.14
Moisture resistance
This clause is not applicable.
K.15
Electric Strength
K.15.1
Materials providing insulation from electric shock shall be adequate.
Compliance is checked by subjecting the insulating material for 1 min to 750 V with a substantially
sinusoidal wave form having a frequency of 50 Hz or 60 Hz. This provision does not exclude the testing of
the material as situated within the tool, providing care is taken to ensure that materials not under
consideration are not subjected to the test voltage.
This test applies only to materials which, if they were to fail to insulate, would subject the user to a shock
hazard from a hazardous voltage. This test does not apply to materials that provide only a physical barrier
to contact. As such, an uninsulated energized part shall be within 1,0 mm of the material surface to be
considered for this requirement.
K.15.1DV D1 Modification: Add the following sentences:
If accessible parts of insulated materials are tested, they shall be covered with metal foil.
No flashover or breakdown shall occur during the test.
K.15.2
This subclause is not applicable.
K.16
Overload protection of transformers and associated circuits
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
This clause is not applicable.

<!-- 第 139 页 -->
K.17
Endurance
This clause is not applicable.
K.18
Abnormal operation
K.18.1
All tools when operating under battery power and their battery packs shall be so designed that the
risk of fire or electric shock as a result of abnormal operation is obviated as far as is practical.
Compliance is checked by the following tests:
The battery tool and battery pack, as is appropriate, are to be placed on a soft wood surface covered by
two layers of tissue paper; the battery tool and battery pack are to be covered by one layer of untreated
100% cotton medical gauze. The test is to be conducted until failure or until the test sample returns to
room temperature. A new sample can be used for each fault listed below. There shall be adequate
protection against electric shock as defined in Clause K.9 and no charring or burning of the gauze or tissue
paper shall result when a battery tool and battery pack are subjected to any one of the following fault
conditions shown below in tests a to f.
Charring is defined as a blackening of the gauze caused by combustion. Discolouration of the gauze
caused by smoke is acceptable.
Thermal cut-outs and thermal overloads may operate during the above tests. In this case, the same test is
to be repeated three more times, using three additional samples. The resistance for the short in items a),
b), d), e) and f) shall not exceed 10 mΩ.
a) The terminals of a detachable battery pack with exposed terminals are shorted. Battery pack
terminals that can be contacted using either Figure 1 or Figure 2 probes are considered exposed.
The means of shorting shall not attain excessive temperatures so as to char or ignite the tissue
paper or gauze.
b) The motor terminals are shorted.
c) The motor rotor is locked.
d) A cord provided between the separable battery pack and the battery tool shall be shorted at the
point likely to produce the most adverse effects.
e) A cord provided between the tool and the charger shall be shorted at the point likely to produce
the most adverse effects.
f) For battery tools a short is introduced between any two uninsulated parts of opposite polarity not
in accordance with the spacings given in clause K.28.
K.18.1DV.1 D2 Modification: Replace Item (b) of Clause K.18.1 with the following:
b) The terminals of each motor are shorted one at a time, except for electronically
commutated motors.
K.18.1.DV.2 D2 Modification: Replace Item (c) of Clause K.18.1 with the following:
c) The rotor of each motor is locked one at a time, except for electronically commutated
motors.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
K.18.2 to K.18.9 These subclauses are not applicable.

<!-- 第 140 页 -->
K.18.12
This subclause is not applicable.
K.19
Mechanical Hazards
K.19.201
If a tool is marked with a direction of movement, it shall not be possible to connect a battery
pack such that the marking is not correct.
K.20
Mechanical strength
K.20.1
Battery tools and battery packs shall have adequate mechanical strength, and shall be so
constructed that they withstand such rough handling as may be expected in normal use.
Compliance is checked by the tests of 20.2 and K.20.3.
Following the test, the battery tool and battery pack shall meet the requirements of Clauses K.9, K.19 and
either K.18.1 f) or K.28.1.
K.20.3
A battery tool with its battery pack attached, shall withstand being dropped three times on a
concrete surface from a height of 1 m. The sample shall be positioned to vary the point of impact.
For battery tools with detachable or separable battery packs, the test is repeated three more times without
the battery pack attached to the tool.
In addition, for detachable or separable battery packs the test is repeated three more times on the battery
packs separately.
New samples may be used for each series of three drops
K.20.4
This subclause is not applicable.
K.21
Construction
K.21.5
This subclause is not applicable.
K.21.6
This subclause is not applicable.
K.21.8 to K.21.16 These subclauses are not applicable.
K.21.21
This subclause is not applicable.
K.21.25 to K.21.34 These subclauses are not applicable.
K.21.201
Tools shall not readily accept general purpose batteries (either primary or rechargeable).
NOTE: Examples of general purpose batteries are AA, C, D, etc.
K.22
Internal wiring
K.22.3
This subclause is applicable only for hazardous voltages.
K.22.4
This subclause is not applicable.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
K.23
Components
K.23.1.10
Power switches shall have adequate breaking capacity.

<!-- 第 141 页 -->
Compliance is checked by subjecting a switch to 50 operations of making and breaking the locked output
mechanism current of the fully charged battery operated tool. Each "on" period has a duration of not more
than 0,5 s and each "off" period having a duration of at least 10 s.
After this test the power switch shall have no electrical or mechanical failure. If the switch operates
properly in the "on" and "off" positions at the end of the test, it is considered to have no mechanical or
electrical failures.
K.23.1.11
Power switches shall withstand, without excessive wear or other harmful effect, the
mechanical, electrical, and thermal stresses occurring in normal use.
Compliance is checked by subjecting a switch to 6 000 cycles of operation making and breaking the
current encountered in the fully charged battery tool operated at no-load. The switch is operated at a
uniform rate of 30 operations per minute. During the test the switch shall operate correctly. After the test,
inspection of the switch shall show no undue wear, no discrepancy between the position of the operating
means and that of the moving contacts, no loosening of electrical or mechanical connections, no seepage
of sealing compound.
K.23.5
This subclause is not applicable.
K.24
Supply connection and external flexible cords
This clause is not applicable, except as follows:
K.24.201
For battery tools with separable battery packs, the external flexible cable or cord shall have
anchorages such that the conductors are relieved from strain, including twisting, where they are connected
within the tool, and protected from abrasion.
Compliance is checked by inspection.
K.25
Terminals for external conductors
This clause is not applicable.
K.26
Provision for earthing
This clause is not applicable.
K.27
Screws and connections
K.27.1
This subclause is applicable except as follows: the sixth paragraph and the accompanying note,
which refers to earthing connections are not applicable.
K.28
Creepage distances, clearances and distances through insulation
K.28.1
Creepage distances and clearances shall not be less than the values in millimetres shown in
Table K.2. The clearances specified do not apply to the air gap between the contacts of thermal controls,
overload protection devices, switches of micro-gap construction, and the like, or to the air gap between the
current-carrying members of such devices where the clearances vary with the movement of the contacts.
Creepages and clearances also do not apply to the construction of battery cells or the interconnections
between cells in a battery pack. The values specified in Table K.2 do not apply to cross-over points of
motor windings.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
For parts having a hazardous voltage between them, the sum total of the measured distances between
each of these parts and their nearest accessible surface shall not be less than 1,5 mm clearance and 2,0
mm creepage.

<!-- 第 142 页 -->
NOTE Figure K.1 provides clarification on the measurement method.
Compliance is checked by measurement.
The way in which creepage distances and clearances are measured is indicated in Annex A.
For parts of different polarity, clearance and creepage distances less than those given in Table K.2 are
acceptable if the shorting of the two parts does not result in the tool starting.
NOTE The risk of fire due to spacings below the required values is covered by the requirements of 18.1.
Table K.2
Minimum creepage distances and clearances between parts of opposite polarity
Dimensions in millimetres
≤15V
>15V and ≤32V
>32V
Creepage
Creepage
Creepage
Distance
Clearance
distance
Clearance
distance
Clearance
–
0,8
–
1,5
2,0
1,5
Distances through slots or openings in external parts of insulating material are measured to the metal foil
in contact with the accessible surface; the foil is pushed into corners and the like by means of the standard
test finger of Figure 1, but is not pressed into openings.
The sum total of distances measured between parts operating at hazardous voltage and accessible
surfaces is determined by measuring the distance from each part to the accessible surface. The distances
are to be added together to determine the sum total. See Figure K.1.
For the purpose of this determination, one of the distances shall be 1,0 mm or greater. See annex A, cases
1 to 10.
If necessary, a force is applied to any point on bare conductors and to the outside of metal enclosures, in
an endeavour to reduce the creepage distances and clearances while taking the measurements.
The force is applied by means of a test finger having a tip as shown in Figure 1 and has a value of:
– 2 N for bare conductors;
– 30 N for enclosures.
If a barrier is interposed, and if it is in two parts which are not cemented together, the creepage distance is
also measured through the joint.
If a barrier is interposed, clearances are measured over the barrier or, if the barrier is in two parts with
mating surfaces which are not cemented together, through the joint.
When assessing creepage distances and clearances, the effect of insulating lining of metal enclosures or
covers is taken into consideration.
Means provided for fixing the tool to a support are considered to be accessible.
K.28.2
This subclause is not applicable.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 143 页 -->
K.29
Resistance to heat, fire and tracking
K.29.1
External parts of non-metallic material, the deterioration of which might cause the tool or battery
pack to fail to comply with this annex, shall be sufficiently resistant to heat.
of the apparatus shown in Figure 5.
Before starting the test the part is maintained for 24 h in an atmosphere having a temperature between 15°
C and 35°C, and a relative humidity between 45% and 75%.
The part is supported so that its upper surface is horizontal and the spherical part of the apparatus is
pressed against this surface with a force of 20 N. The thickness of the part under test shall be at least 2,5
mm. The required thickness may be obtained by using two or more sections of the part.
The test is made in a heating cabinet at a temperature of (40 ±2) °C plus the maximum temperature rise
determined during the test of K.12, but it shall be at least:
– for external parts (75 ±2) °C.
Before the test is started, the test apparatus is brought to the temperature determined above.
After 1 h, the apparatus is removed and the part is immediately immersed in cold water so that it is cooled
to room temperature within 10 s. The diameter of the impression shall not exceed 2 mm. The test is not
made on parts of ceramic material.
K.29.2
This subclause applies only to the external enclosure enclosing the current-carrying part of the
tool or battery pack.
K.29.3
This subclause is not applicable.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 144 页 -->
Figure K.1
Measurement of clearances
Dimension a = distance from positive bare conductive part to the external surface as defined by foil stretched across the openings.
Dimension b = distance from negative bare conductive part to the external surface as defined by foil stretched across the openings.
a + b is the sum total as defined in K.28.1.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 145 页 -->
Annex L
(normative)
Battery tools and battery packs provided with mains connection or non-isolated sources
L.1
Scope
This annex applies to rechargeable battery-powered motor-operated or magnetically driven tools and the
battery packs for such tools that are also operated and/or charged directly from the mains or a non-
isolated source, including tools provided with integral battery chargers. This annex applies to tools
incorporating detachable, integral and separable battery packs. The maximum rated voltages for tools are
250 V single phase a.c. or d.c. mains source and 75 V d.c. battery source. The maximum rated voltage for
battery packs is 75 V d.c.
Battery packs for tools covered under this annex intended to be charged by a non-isolated charger shall
be evaluated by this annex and standard. When evaluating a battery pack for protection against electric
shock, creepage distances, clearances and distances through insulation, the battery pack shall be fitted to
the intended charger.
All clauses of this standard apply unless otherwise specified in this annex. If a clause is stated in the
annex, the requirements replace the requirements of the standard.
For the purpose of the tools covered by this annex, the term "mains switch" as it appears in the standard is
understood to refer to the power switch of the battery-operated tool.
This annex is not intended to apply to tools using general purpose batteries installed by the user and this
annex alone will not be sufficient to ensure all hazards are considered for these products.
This annex does not apply to battery chargers which are covered by IEC 60335-2-29.
L.2
Normative References
This clause is applicable except as follows:
Additional normative reference:
IEC 61558-2-6:1997, Safety of power transformers, power supply units and similar – Part 2: Particular
requirements for safety isolating transformers for general use
L.3
Terms and definitions
For the purpose of this annex, the following definitions apply:
L.3.201
battery pack: assembly of one or more cells intended to provide electrical current to the tool
L.3.201.1
detachable battery pack: a battery pack which is contained in a separate enclosure from the
battery tool and is intended to be removed from the tool for charging purposes
L.3.201.2
integral battery pack: A battery pack which is contained within the battery tool and is not
removed from the battery tool for charging purposes. A battery pack that is to be removed from the battery
tool for disposal or recycling purposes only is considered to be an integral battery pack
L.3.201.3
separable battery pack: A battery pack which is contained in a separate enclosure from the
battery tool and is connected to the battery tool by a cord
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 146 页 -->
L.3.202
fully charged battery pack: A battery pack which has been through at least two discharge and
charge cycles with an interval of at least two hours after each cycle in accordance with the manufacturer's
instructions
L.3.203
non-isolated source: A voltage source in which the output is not isolated from the mains supply
by means of a safety isolating transformer as specified
L.3.204
hazardous voltage: A voltage between parts having an average value exceeding 60 V d.c. or
42,4 V peak when the peak to peak ripple exceeds 10% of the average value
L.3.205
power switch: power switch that controls the primary operating means of the tool
L.3.206
interconnecting cord: external flexible cord provided as part of a complete tool for purposes
other than connection to the supply mains
NOTE A remote hand-held switching device, an external interconnection between two parts of a tool and a cord connecting
an accessory to the tool or to a separate signalling circuit are examples of interconnecting cords
L.5
General conditions for the tests
L.5.201
Unless otherwise specified, a fully charged battery pack shall be used for each test.
L.5.202
When measuring voltage, the peak value of any superimposed ripple exceeding 10% of the
average value shall be included. Transient voltages are ignored, such as a temporary increase above
rated voltage, such as after the battery pack is removed from the charger.
L.7
Classification
L.7.1
This subclause applies except that class III tools are not considered in this annex.
L.8
Marking and Instructions
L.8.1
The first paragraph of this subclause is replaced by the following:
Non-isolated sources that can supply a tool, or tools that can be supplied directly from the mains, shall be
marked with the following. In the case of tools supplied directly from the mains, these markings shall
include those for both mains and battery operation:
– rated voltage(s) or rated voltage range(s), in volts;
– symbol for nature of supply;
– rated input, in watts, or rated current in amperes;
– name or trade mark or identification mark of the manufacturer or responsible vendor;
– model or type reference;
– symbol for class II construction, for class II tools only;
– manufacturer's address or country of origin;
– any mandatory mark showing compliance with legislation by reference to this standard.
Compliance is checked by inspection.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
L.8.1.201
Tools, other than those that can be supplied directly from the mains, and detachable or
separable battery packs shall be marked with:

<!-- 第 147 页 -->
– rated voltage(s) or rated voltage range(s), in volts;
– symbol for nature of supply;
– name or trade mark or identification mark of the manufacturer or responsible vendor;
– model or type reference;
– manufacturer's address or country of origin;
– any mandatory mark showing compliance with legislation by reference to this standard.
Additional markings shall not give rise to misunderstanding.
Compliance is checked by inspection.
L.8.12.1.1
This subclause is applicable except as follows:
Item 5) Service, is replaced by the following:
5) Battery tool use and care
a) Recharge only with the charger specified by the manufacturer. A charger that is suitable for
one type of battery pack may create a risk of fire when used with another battery pack.
b) Use power tools only with specifically designated battery packs. Use of any other battery
packs may create a risk of injury and fire.
c) When battery pack is not in use, keep it away from other metal objects like paper clips,
coins, keys, nails, screws, or other small metal objects, that can make a connection from
one terminal to another. Shorting the battery terminals together may cause burns or a fire.
d) Under abusive conditions, liquid may be ejected from the battery; avoid contact. If
contact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek
medical help. Liquid ejected from the battery may cause irritation or burns.
6) Service
a) Have your power tool serviced by a qualified repair person using only identical
replacement parts. This will ensure that the safety of the power tool is maintained.
L.8.12.1.1DV D2 Modification: Add the following paragraph to Clause L.8.12.1.1:
Clauses 8.12.1.1, 8.12.1.2, 8.12.2 (first paragraph and associated warnings only) may be
replaced in their entirety with Clauses 8.14.1.1, 8.14.1.2, and 8.14.1.3 of UL 62841-1 or
CAN/CSA C22.2 No. 62841-1. Partial substitution of the above-mentioned set of clauses
between standards is not permitted.
L.9
Protection against electric shock
NOTE The title of this clause differs from that of the main standard.
The requirements of 9.1 through 9.4 apply for all conditions along with the following addition:
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Addition:

<!-- 第 148 页 -->
Tools covered by this annex and their battery packs shall be so constructed and enclosed that there is
adequate protection against electric shock.
non-isolated source. During the evaluation in this condition, battery packs are to be connected to the tool
in the normal fashion. The tool is also evaluated with the battery pack removed if such removal can be
accomplished without the use of a tool.
L.9.1.201
For battery packs which may be disconnected from the tool and tools operated under battery
power it shall not be possible to have two conductive, simultaneously accessible parts where the voltage
between them is hazardous, unless they are provided with protective impedance.
In the case of protective impedance the short circuit current between the parts shall not exceed 2 mA for d.
c. or 0,7 mA peak for a.c. and there shall not be more than 0,1 µF capacitance directly between the parts.
Compliance for accessibility is checked by applying the test finger of Figure 1 to each conductive part.
The test finger of Figure 1 is applied without any appreciable force through openings to any depth that the
finger will permit, and it is rotated or angled before, during and after insertion to any position.
If the opening does not allow entry of the finger, the force on the finger in the straight position is increased
to 20 N and the test with the finger bent repeated.
Contact with the test finger is determined with all detachable parts removed and the battery tool operated
in any possible position of normal use.
Lamps located behind detachable covers are not removed, providing the lamp may be de-energized by
means of a user operable plug, battery disconnection or a switch.
L.10
Starting
This clause only applies when the tool is in the configuration where it is directly connected to the mains or
to a non-isolated source.
L.11
Input and current
This clause only applies when the tool is in the configuration where it is directly connected to the mains or
to a non-isolated source. In the case of tools that can also charge the battery while performing their
intended function, the test is conducted while charging a previously discharged battery pack.
L.12
Heating
This clause only applies when the tool is in the configuration where it is directly connected to the mains or
to a non-isolated source. In the case of tools that can also charge the battery pack while performing their
intended function, they are tested with the charger connected and are operated at no load until the tool
stops operating due to the battery pack being discharged or until thermal stabilization is achieved,
whichever occurs first. The test is repeated, allowing the battery pack to charge while the tool is not
operating.
L.13
Leakage current
This clause only applies when the tool is in the configuration where it is directly connected to the mains or
to a non-isolated source.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 149 页 -->
L.14
Moisture resistance
This clause only applies when the tool is in the configuration where it is directly connected to the mains or
to a non-isolated source.
L.15
Electric strength
This clause only applies when the tool is in the configuration where it is directly connected to the mains or
to a non-isolated source. Care shall be taken that the premature failure of electronic devices does not
prevent the application of the test voltage across insulation. If this is the case, electronic devices may be
bypassed to enable the test to be conducted.
L.16
Overload protection of transformers and associated circuits
This clause only applies when the tool is in the configuration where it is directly connected to the mains or
to a non-isolated source.
L.17
Endurance
This clause applies to tools capable of continuous operation when they are supplied directly from the
mains or from a non-isolated source. Tools that are not capable of continuous operation shall be operated
from under battery power for the duration of the test but shall be evaluated for electric strength with their
charger connected.
L.18
Abnormal operation
This clause only applies when the tool is in the configuration where it is directly connected to the mains or
to a non-isolated source.
L.18.201
All tools when operating only under battery power and their battery packs shall be so designed
that the risk of fire or electric shock as a result of abnormal operation is obviated as far as is practical.
Compliance is checked by the following tests:
The battery tool and battery pack, as is appropriate, are to be placed on a soft wood surface covered by
two layers of tissue paper; the battery tool and battery pack are to be covered by one layer of untreated
100% cotton medical gauze. The test is to be conducted until failure or until the test sample returns to
room temperature. A new sample can be used for each fault listed below. There shall be adequate
protection against electric shock as defined in Clauses L.9 and L.13 and no charring or burning of the
gauze or tissue paper shall result when a battery tool and battery pack are subjected to any one of the
following fault conditions shown below in tests a) to f).
Charring is defined as a blackening of the gauze caused by combustion. Discolouration of the gauze
caused by smoke is acceptable.
Thermal cut-outs and thermal overloads may operate during the above tests. In this case, the same test is
to be repeated three more times, using three additional samples. The resistance for the short in items a),
b), d), e) and f) shall not exceed 10 mΩ.
a) The terminals of a detachable battery pack with exposed terminals are shorted. Battery pack
terminals that can be contacted using either Figure 1 or Figure 2 probes are considered exposed.
The means of shorting shall not attain excessive temperatures so as to char or ignite the tissue
paper or gauze.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
b) The motor terminals are shorted.
c) The motor rotor is locked.

<!-- 第 150 页 -->
d) A cord provided between the separable battery pack and the battery tool shall be shorted at the
point likely to produce the most adverse effects.
e) A cord provided between the tool and the charger shall be shorted at the point likely to produce
the most adverse effects.
f) For battery tools a short is introduced between any two uninsulated parts of opposite polarity not
in accordance with the spacings given in L.28.201.
L.18.201DV.1 D2 Modification: Replace Item (b) of Clause L.18.201 with the following:
b) The terminals of each motor are shorted one at a time, except for electronically
commutated motors.
L.18.201DV.2 D2 Modification: Replace Item (c) of Clause L.18.201 with the following:
c) The rotor of each motor is locked one at a time, except for electronically
commutated motors.
L.19
Mechanical Hazards
L.19.201
If a tool is marked with a direction of movement it shall not be possible to connect a battery
pack such that the marking is not correct.
L.20
Mechanical strength
This clause only applies when the tool is in the configuration where it is directly connected to the mains or
to a non-isolated source.
L.20.201
With the battery connected, battery tools and battery packs shall have adequate mechanical
strength, and shall be so constructed that they withstand such rough handling as may be expected in
normal use.
A battery tool with its battery pack attached, shall withstand being dropped three times on a concrete
surface from a height of 1 m. The sample shall be positioned to vary the point of impact.
For battery tools with detachable or separable battery packs, the test is repeated three more times without
the battery pack attached to the tool.
In addition for detachable or separable battery packs the test is repeated three more times on the battery
packs separately.
New samples may be used for each series of three drops.
Following the test, the battery tool and battery pack shall meet the requirements of Clauses L.9, L.19,
L.28.1 and either L.18.201(f) or L.28.201.
L.21
Construction
This clause only applies when the tool is in the configuration where it is directly connected to the mains or
to a non-isolated source.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 151 页 -->
L.22
Internal wiring
This clause only applies when the tool is in the configuration where it is directly connected to the mains or
to a non-isolated source.
L.23
Components
L.23.1.10
The subclause of the standard applies only to tools capable of performing their intended
operation when connected to the mains or to a non-isolated source for those switches that control the
primary operating means of the tool.
L.23.1.10.201
Switches, other than those of tools described in L.23.1.10, that control the primary
operating means of the tool shall have adequate breaking capacity.
Compliance is checked by subjecting a switch to 50 operations of making and breaking the locked output
mechanism current of the fully charged battery-operated tool. Each "on" period having a duration of not
more than 0,5 s and each "off" period having a duration of at least 10 s.
After this test the power switch shall have no electrical or mechanical failure. If the switch operates
properly in the on and off positions at the end of the test, it is considered to have no mechanical or
electrical failures.
L.23.1.11
The subclause of the standard applies only to tools capable of performing their intended
operation when connected to the mains or to a non-isolated source for those switches that control the
primary operating means of the tool.
L.23.1.11.201
Switches, other than those described in L.23.1.11, that control the primary operating
means of the tool, shall withstand, without excessive wear or other harmful effect, the mechanical,
electrical, and thermal stresses occurring in normal use.
Compliance is checked by subjecting a switch to 6 000 cycles of operation making and breaking the
current encountered in the fully charged battery tool operated at no-load. The switch is operated at a
uniform rate of 30 operations per minute. During the test the switch shall operate correctly. After the test,
inspection of the switch shall show no undue wear, no discrepancy between the position of the operating
means and that of the moving contacts, no loosening of electrical or mechanical connections, no seepage
of sealing compound.
L.24
Supply connection and external flexible cords
L.24.1
This subclause also applies to a flexible cord between a non-isolated power source and the tool.
L.24.3
This subclause also applies to a flexible cord between a non-isolated power source and the tool.
L.24.4
This subclause applies, except a flexible cord provided between a non-isolated power source and
the tool shall not be provided with a plug that can be connected directly to the mains.
L.24.5
This subclause does not apply to a flexible cord provided between a non-isolated power source
and the tool.
L.24.21
This subclause applies, except a flexible cord provided between a non-isolated power source
and the tool shall not be provided with an appliance inlet that can be connected directly to the mains.
L.24.201
For battery tools with separable battery packs, the external flexible cable or cord shall have
anchorages such that the conductors are relieved from strain, including twisting, where they are connected
within the tool, and protected from abrasion.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 152 页 -->
Compliance is checked by inspection.
L.25
Terminals for external conductors
This clause does not apply to interconnecting cords.
L.26
Provision for earthing
L.28
Creepage distances, clearances and distances through insulation
The clause of the standard is applicable except as follows:
L.28.1
Addition:
NOTE Figure L.1 provides clarification on the measurement method.
Compliance is checked by measurement.
The way in which creepage distances and clearances are measured is indicated in annex A.
NOTE The risk of fire due to spacings below the required values is covered by the requirements of 18.1.
Creepage
Creepage
Distance
Clearance
CAN/CSA-C22.2 No. 60745-1-07 ♦UL 60745-1
APRIL 30, 2020
This clause only applies when the tool is in the configuration where it is directly connected to the mains or
to a non-isolated source.
This subclause only applies when the tool is in the configuration where it is directly connected to the mains
or to a non-isolated source. During the evaluation in this condition, battery packs are to be connected to
the tool. The tool is also evaluated with the battery pack removed if such removal can be accomplished
without the use of a tool.
L.28.201
Creepage distances and clearances shall not be less than values in millimetres shown in Table
L.1. The clearances specified do not apply to the air gap between the contacts of thermal controls,
overload protection devices, switches of micro-gap construction, and the like, or to the air gap between the
current-carrying members of such devices where the clearances vary with the movement of the contacts.
Creepages and clearances also do not apply to the construction of battery cells or the interconnections
between cells in a battery pack. The values specified in Table L.1 do not apply to cross-over points of
motor windings.
For parts having a hazardous voltage between them, the sum total of the measured distances between
each of these parts and their nearest accessible surface shall not be less than 1,5 mm clearance and 2,0
mm creepage.
For parts of different polarity, clearance and creepage distances less than those given in Table L.1 are
acceptable if the shorting of the two parts does not result in the tool starting.
Table L.1
Minimum creepage distances and clearances between parts of opposite polarity
Dimensions in millimetres
≤15V
>15V and ≤32V
>32V
Creepage
distance
Clearance
distance
Clearance
–
0,8
–
1,5
2,0
1,5
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 153 页 -->
Distances through slots or openings in external parts of insulating material are measured to metal foil in
contact with the accessible surface; the foil is pushed into corners and the like by means of the standard
test finger of Figure 1, but is not pressed into openings.
The sum total of distances measured between parts operating at hazardous voltage and accessible
surfaces is determined by measuring the distance from each part to the accessible surface. The distances
are to be added together to determine the sum total. See Figure L.1. For the purpose of this determination,
one of the distances shall be 1,0 mm or greater. See annex A, cases 1 to 10.
If necessary, a force is applied to any point on bare conductors and to the outside of metal enclosures, in
an endeavour to reduce the creepage distances and clearances while taking the measurements.
The force is applied by means of a test finger having a tip as shown in Figure 1 and has a value of:
– 2 N for bare conductors;
– 30 N for enclosures.
If a barrier is interposed, and if it is in two parts which are not cemented together, the creepage distance is
also measured through the joint.
If a barrier is interposed, clearances are measured over the barrier or, if the barrier is in two parts with
mating surfaces which are not cemented together, through the joint.
When assessing creepage distances and clearances, the effect of insulating lining of metal enclosures or
covers is taken into consideration.
Means provided for fixing the tool to a support are considered to be accessible.
L.29
Resistance to heat, fire and tracking
The clause of the standard is applicable except as follows:
L.29.1
Addition:
This subclause only applies when the tool is in the configuration where it is directly connected to the mains
or to a non-isolated source.
In the case of tools that can charge the battery while performing their intended function, the battery pack
shall be evaluated with the charger connected to the mains and with a battery in a condition that results in
the most unfavourable temperatures.
In addition, tools capable of charging the battery and which may also be capable of performing its intended
operation shall also be evaluated with battery power alone if this may create temperatures that are more
unfavourable. For the purposes of this clause, a part that is energized only by a battery source is not to be
considered live.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 154 页 -->
Figure L.1
Measurement of clearances
Dimension a – distance from positive bare conductive part to the external surface as defined by foil stretched across the openings.
Dimension b – distance from negative bare conductive part to the external surface as defined by foil stretched across the openings.
a + b is the sum total as defined in clause L.28.201
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 155 页 -->
Annex M
(normative)
Safety of working stands for operation with hand-held motor-operated electric tools
M.1
Scope
This annex applies to working stands with and without mains supply, and intended to be used in
combination with hand-held electric tools but not intended for continuous production or production line use.
All clauses of this standard apply as far as reasonable for the type of working stand, unless otherwise
specified in this annex.
For the purpose of this annex, the term “tool” as it appears in the main body of this standard is understood
to refer to the working stand.
M.2
Normative references
This clause is applicable except as follows:
Additional normative references:
M.2DV DC Modification: Add the following sentence:
Where IEC or ISO normative documents are referenced in this standard, US and Canadian
standards shall replace the IEC or ISO documents.
IEC 60204-1;
Safety of machinery – Electrical equipment of machines – Part 1: General requirements
M.3
Terms and Definitions
This clause is applicable except as follows:
M.3.201
working stand: device that a hand held electric motor operated tool is attached to in order to
operate as a stationary electric motor-operated tool. Some working stands integrate clamping devices,
protective equipment and supports for accessories (saw blades, bits and the like)
M.3.202
adjusting/control device: device used to adjust/control a function of the working stand or tool
M.3.203
dust collection equipment: device intended to remove and collect dust and chips, either
integral or with optional connection to an external suction equipment
M.5
General conditions for the tests
This clause is applicable except as follows:
M.5.201
If the test results for the working stand, under any clause of this standard, are dependent on the
tool used on the working stand, then the tool / working stand combination stated in M.8.12.2 a) 201) that
leads to the most unfavourable results shall be tested.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
For the tool / working stand combinations stated in M.8.12.2 a) 201), the working stand shall not adversely
affect the safety of the tool when used in combination with such.

<!-- 第 156 页 -->
M.7
Classification
This clause is applicable except as follows:
M.7.1
Replacement:
If the working stand is designed for
– Class I tools or
– Class I and Class II tools,
Parts of the electrical system supplying the tool shall be of Class I.
If the working stand is designed for Class II tools, parts of the electrical system supplying the tool shall be
of Class I or Class II.
Compliance is checked by inspection and by the relevant tests.
M.8
Marking and instructions
This clause is applicable except as follows:
M.8.1
Addition:
The working stand shall be marked with capacities, such as power, weight, dimensions, as specified in the
relevant part 2.
M.8.12.1.1
Replacement:
General Working Stand Safety Warnings
WARNING Read all safety warnings and all instructions provided with the working stand and the
power tool to be mounted. Failure to follow the warnings and instructions may result in electric shock,
fire and/or serious injury.
Save all warnings and instructions for future reference.
The term "power tool" in the warnings refers to your mains-operated (corded) power tool or battery-
operated (cordless) power tool.
NOTE The terms "working stand" and "power tool" may be substituted by a specific name, i.e. "router table" and "router".
Disconnect the plug from the power source and/or the battery pack from the power tool before
making any adjustments or changing accessories. Accidental starting of the power tool is a cause of
some accidents.
Properly assemble the working stand before mounting the tool. Proper assembly is important to
prevent risk of collapse.
Securely fasten the power tool to the working stand before use. Power tool shifting on the working
stand can cause loss of control.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Place the working stand on a solid, flat and level surface. When the working stand can shift or rock,
the power tool or workpiece cannot be steadily and safely controlled.

<!-- 第 157 页 -->
Do not overload the working stand or use as ladder or scaffolding. Overloading or standing on the
working stand causes the stand to be “top-heavy” and likely to tip over.
NOTE The above warning may be omitted if the working stand is unlikely to be used as ladder or scaffolding, e.g. because it
is too small.
M.8.12.2
a) Addition:
201) Information about the electric tools intended to be installed in the working stand and a warning
to hazards if an electric tool is installed which is not intended for use with this working stand.
202) If applicable, the instruction manual shall provide information on how to assemble and secure
the stand to the floor, bench, etc.
M.10
Starting
This clause is not applicable.
M.11
Input and current
This clause is not applicable.
M.17
Endurance
This clause is applicable except as follows:
M.17.2
Replacement of the fifth paragraph:
The test is performed in the normal operating position of the working stand.
M.19
Mechanical hazards
This clause is applicable except as follows:
M.19.201
Working stands which may be used without fixing to the floor or to a table shall have adequate
stability.
Compliance is checked by the following test:
Working stands with an appliance inlet are fitted with an appropriate connector and a flexible cable or cord.
The working stand fitted with the electric tool is placed with the electric tool switched off in any normal
position of use on a plane inclined at an angle of 10° to the horizontal, the cable or cord resting on the
inclined plane in the most unfavourable position. If, however, the working stand is such that, were it to be
tilted through an angle of 10° when standing on a horizontal plane, a part of the working stand normally not
in contact with the supporting surface would touch the horizontal plane, the working stand is placed on a
horizontal plane and tilted in the most unfavourable direction through an angle of 10°.
Working stands with doors are tested with the doors open or closed whichever is the most unfavourable.
Working stands intended to be filled with liquid by the user in normal use are tested empty or filled with the
most unfavourable quantity of water or the recommended liquid, up to the rated capacity.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
The working stand shall not overturn.

<!-- 第 158 页 -->
M.19.202
Screws which make a mechanical connection between different parts of the working stand
shall not become loose in normal use.
Compliance is checked by inspection.
M.19.203
Any protective devices such as guards, which are necessary for the combination of the
working stand and the tool shall be delivered with the working stand. It is stated in the relevant part 2 which
protective devices are required to be delivered with the working stand.
Compliance is checked by inspection.
M.19.204
Use of a tool with a stand shall not impair the safety of the hand-held tool when removed from
the stand and used as a stand-alone product.
Compliance is checked by inspection.
M.21
Construction
This clause is applicable except as follows:
M.21.17
Replacement:
Switches shall be so located that accidental operation is unlikely to occur.
Compliance is checked by applying a sphere with a diameter of 100 mm ± 1 mm to the switch. It shall not
be possible to start the electric tool by means of the sphere.
M.21.18
Replacement:
The mains switch of the working stand or of the hand-held motor-operated electric tools shall be so located
that it can be switched on and off by the user from the operator’s position. When a switch has a locking
arrangement to lock it in the "on" position, the requirement in M.21.18 is considered as being met provided
the switch unlocks automatically when the trigger or actuating member is actuated.
It is stated in the relevant part 2, whether a working stand shall be fitted with a switch to start and stop the
installed electric tool.
Compliance is checked by inspection and by manual test.
M.21.201
A handle, a lever, a knob, or other control that is likely to be actuated while the tool is in
operation shall be so located that, from the operator’s position, it is not necessary to traverse an area that
may involve a risk of injury when reaching for it.
If an area that may involve a risk of injury is adjacent to the control then this area shall be guarded or so
located that it cannot be entered unintentionally.
Compliance is checked by inspection.
M.21.202
Working stands shall be equipped with facilities needed to fix the hand-held electric tools
which are intended to be installed.
Compliance is checked by inspection.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
M.21.203
After voltage recovery, following an interruption of the power supply, the reactivation of the
electric tool/working stand shall not cause a hazard.

<!-- 第 159 页 -->
The relevant part 2 shall state if this clause is applicable.
Compliance is checked by inspection.
M.21.204
If the tool is provided with a dust collection system, the working stand shall be designed such
that in normal use the dust-collection devices on the tool can be used without any restriction.
Alternatively the working stand itself may be fitted with dust-collection devices, either integral or to be
connected to external dust collection equipment, that performs in an equivalent manner.
If additional measures are necessary for dust collection, this is stated in the relevant part 2.
Compliance is checked by inspection and by manual test.
M.23
Components
This clause is applicable except as follows:
M.23.1.10
Replacement:
Mains switches shall be rated for at least the tool with the highest rated input or rated current
recommended by the manufacturer and shall be rated for 10 000 cycles of operation.
Compliance is checked by inspection and by the following test which shall be performed with the hand-
manufacturer.
The mains switch of the working stand is tested at rated voltage or at the upper limit of the rated voltage
range of the tool.
The motor is then stalled, and the switch is operated 50 times, each "on" period being not more than 0,5 s,
and each "off" period being not less than 10 s.
Compliance is checked by inspection and by the following test which shall be performed with the hand-
manufacturer.
The mains switch of the working stand is tested at rated voltage or at the upper limit of the rated voltage
range of the tool.
The motor is then stalled, and the switch is operated 50 times, each "on" period being not more than 0,5 s,
and each "off" period being not less than 10 s.
If, in normal use, an electronic control device switches off the current before opening the main contacts,
the number of operations is reduced to five, with the electronic control device shortcircuited.
After the test, the switch shall have no electrical or mechanical failure.
Mains switches marked with individual ratings are also tested in accordance with IEC 61058-1.
M.23.1.11
Replacement:
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
Switches, which have not been separately tested and found to comply with IEC 61058-1 under the
conditions occurring in the tool shall comply with Annex I.

<!-- 第 160 页 -->
The test of 17.2.4.4 of IEC 61058-1 is carried out for 10 000 cycles of operation.
Switches intended for operation under no-load, and which can be operated only with the aid of a tool, are
which are interlocked so that they cannot be operated under load, but switches without that interlock are
subjected to the test of 17.2.4.4 for 100 cycles of operation.
The tests of 17.2.4.4 of IEC 61058-1 are not carried out on a switch if the working stand meets the
requirements of this standard when the switch is short-circuited.
M.24
Supply connection and external flexible cords
This clause is applicable except as follows:
M.24.12
This subclause in not applicable.
M.25
Terminals for external conductors
This clause is applicable except as follows:
M.25.201
Terminals shall comply with IEC 60204-1.
Compliance is checked by inspection.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 161 页 -->
Annex N
(normative)
Rules for routine tests
N.1
General
The tests specified in this annex are intended to reveal, as far as safety is concerned, unacceptable
variations in material or manufacture. These production tests do not impair the properties and the reliability
of the tool, and should be made by the manufacturer on each tool.
manufacturer to ensure that every tool conforms with the samples that withstood the tests of this
specification, according to the experience gained by the manufacturer.
The manufacturer may use a test procedure which is better suited to his production arrangements and
may make the tests at an appropriate stage during production provided it can be shown that tools which
withstand the tests carried out by the manufacturer provide at least the same degree of safety as tools
which the tests specified in this annex.
N.2
Correct operation test
The safe operation shall be checked, for example, by electrical measurements, by verifying the functional
devices, such as switches and manually-operated controls, and by verifying the direction of rotation of
motors.
N.3
Electric strength test
The insulation of the tools shall be checked by the following test:
A voltage of substantially sine-wave form, having a frequency of 50 Hz or 60 Hz and the value shown in
Table N.1, is immediately applied, for 3 s, between live parts and:
a) accessible metal parts which may become live in the event of an insulation fault or as a result of
incorrect assembly;
b) inaccessible metal parts.
The tests of item a) are made on the assembled tool; the test of item b) is made on the tool, either
completely assembled, or in the production line.
The tests of item a) are made on all tools, the tests of item b) being only made on class II tools.
The high-voltage transformer used for the tests shall be so designed that, when the output terminals are
short-circuited after the output voltage has been adjusted to the appropriate test voltage, the output
current is at least 200 mA.
The overcurrent relay shall trip when the output current exceeds 5 mA.
Care shall be taken that the r.m.s. value of the test voltage applied is measured within ± 3% and that the
voltage measuring device or other indicator responds to the output voltage of the transformer.
Attention is drawn to the fact that the test described cannot always be used if the tool incorporates d.c.
components; in such cases, tests with d.c. may be necessary.
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
The inherent resistance of the d.c. source shall allow a short-circuit current of at least 200 mA.

<!-- 第 162 页 -->
No flashover or breakdown shall occur during the tests.
Table N.1
Test voltages for the electric strength test
Application of test voltage
Test voltage V
Class III tools
Class II tools
Class I tools
Over basic insulation
1 000
1 000
Over double insulation or
reinforced insulation
–
2 500
–
N.4
Earthing continuity test
For class I tools, a current of at least 10 A, derived from an a. c. source having a no-load voltage not
exceeding 12 V, is passed between the earthing terminal or the earthing contact and, in turn, each of the
accessible metal parts which need to be earthed for safety reasons.
The voltage drop between the earthing contact of the plug or the external end of an earth continuity
conductor or of the appliance inlet and the accessible metal part is measured, and the resistance
calculated from the current and this voltage drop.
In no case shall the resistance exceed 0,3 Ω. This value is applicable to supply cable lengths up to 5 m. In
case of supply cables having a length exceeding 5 m it is increased by 0,12 Ωfor any further length of 5 m.
Care shall be taken that the contact resistance between the tip of the measuring probe and the metal parts
under test does not influence the test results.
Annex DVN National Difference Deleted
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 163 页 -->
Bibliography
IEC 60335-2-29,
Household and similar electrical appliances – Safety – Part 2: Particular requirements for battery chargers
IEC 60335-2-45,
Safety of household and similar electrical appliances – Safety – Part 2: Particular requirements for
portable heating tools and similar appliances
IEC 60601
(all parts), Medical electrical equipment
IEC 61000-3-2,
Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions (equipment
input current ≤16 A per phase)
IEC 61000-3-3,
Electromagnetic compatibility (EMC) – Part 3: Limits – Section 3: Limitation of voltage fluctuations and
flicker in low-voltage supply systems for equipment with rated current ≤16 A
CISPR 11,
Industrial, scientific and medical (ISM) radio-frequency equipment – Electro-magnetic disturbance
characteristics – Limits and methods of measurement
CISPR 14-1,
Electromagnetic compatibility – Requirements for household appliances, electric tools and similar
apparatus – Part 1: Emission
CISPR 14-2,
Electromagnetic compatibility – Requirements for household appliances, electric tools and similar
apparatus – Part 2: Immunity – Product family standard
UL COPYRIGHTED MATERIAL –
NOT AUTHORIZED FOR FURTHER REPRODUCTION OR

<!-- 第 164 页 -->
333 Pfingsten Road
Northbrook, Illinois 60062–2096
847.272.8800
For other locations in the UL family of companies,
please visit UL.com/contact