# IEC 62841-2-14 IEC 62841-2-14

- 标准号：IEC 62841-2-14　年份：—　文件名状态：—
- 来源 PDF：`安全标准\电动工具\62841系列\IEC 62841-2-14.pdf`
- 页数：24　提取字符：33,495　页眉页脚过滤：1 条
- 文字层完整性：full（每页数字中位数 39.0）　语种：英文　小数：完整 95 / 疑似残缺 0
- 提取时间：2026-11-03　方式：文字层直提（未 OCR）
- 正文可疑：否

> 本页眉之后是原文，按页排列。**表格线、图样、尺寸标注在纯文本里会走形，判定试验参数时以 PDF 原件为准。**


<!-- 第 1 页 -->
®
IEC 62841-2-14:2015-06(en)
IEC 62841-2-14
Edition 1.0 2015-06 
INTERNATIONAL 
STANDARD
Electric motor-operated hand-held tools, transportable tools and lawn and 
garden machinery – Safety –  
Part 2-14: Particular requirements for hand-held planers

<!-- 第 2 页 -->
THIS PUBLICATION IS COPYRIGHT PROTECTED 
Copyright © 2015 IEC, Geneva, Switzerland  
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form 
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from 
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC 
copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or 
your local IEC member National Committee for further information.
IEC Central Office 
Tel.: +41 22 919 02 11 
3, rue de Varembé 
Fax: +41 22 919 03 00 
CH-1211 Geneva 20 
info@iec.ch 
Switzerland 
www.iec.ch
About the IEC 
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes 
International Standards for all electrical, electronic and related technologies. 
About IEC publications  
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the 
latest edition, a corrigenda or an amendment might have been published. 
IEC Catalogue - webstore.iec.ch/catalogue 
The stand-alone application for consulting the entire 
bibliographical information on IEC International Standards, 
Technical Specifications, Technical Reports and other 
documents. Available for PC, Mac OS, Android Tablets and 
iPad. 
IEC publications search - www.iec.ch/searchpub 
variety 
of 
criteria 
(reference 
number, 
text, 
technical 
committee,…). It also gives information on projects, replaced 
and withdrawn publications. 
IEC Just Published - webstore.iec.ch/justpublished 
Stay up to date on all new IEC publications. Just Published 
details all new publications released. Available online and 
also once a month by email.
The world's leading online dictionary of electronic and 
electrical terms containing more than 30 000 terms and 
definitions in English and French, with equivalent terms in 15 
additional languages. Also known as the International 
Electrotechnical Vocabulary (IEV) online. 
IEC Glossary - std.iec.ch/glossary 
More than 60 000 electrotechnical terminology entries in 
English and French extracted from the Terms and Definitions 
clause of IEC publications issued since 2002. Some entries 
have been collected from earlier publications of IEC TC 37, 
77, 86 and CISPR. 
IEC Customer Service Centre - webstore.iec.ch/csc 
If you wish to give us your feedback on this publication or 
need further assistance, please contact the Customer Service 
Centre: csc@iec.ch.

<!-- 第 3 页 -->
®
Electric motor-operated hand-held tools, transportable tools and lawn and 
garden machinery – Safety –  
Part 2-14: Particular requirements for hand-held planers
ICS 25.140.20
IEC 62841-2-14
Edition 1.0 2015-06 
INTERNATIONAL 
STANDARD
INTERNATIONAL 
ELECTROTECHNICAL 
COMMISSION
ISBN 978-2-8322-2770-1

<!-- 第 4 页 -->
CONTENTS
FOREWORD ......................................................................................................................... 3
Scope ............................................................................................................................ 5
Normative references..................................................................................................... 5
Terms and definitions .................................................................................................... 5
General requirements .................................................................................................... 5
General conditions for the tests ...................................................................................... 5
Radiation, toxicity and similar hazards ........................................................................... 6
Classification ................................................................................................................. 6
Marking and instructions ................................................................................................ 6
Protection against access to live parts ........................................................................... 6
Starting ......................................................................................................................... 6
Input and current ........................................................................................................... 7
Heating ......................................................................................................................... 7
Resistance to heat and fire ............................................................................................ 7
Moisture resistance ....................................................................................................... 7
Resistance to rusting ..................................................................................................... 7
Overload protection of transformers and associated circuits ............................................ 7
Endurance ..................................................................................................................... 7
Abnormal operation ....................................................................................................... 7
Mechanical hazards ....................................................................................................... 8
Mechanical strength ..................................................................................................... 10
Construction ................................................................................................................ 10
Internal wiring .............................................................................................................. 11
Components ................................................................................................................ 11
Supply connection and external flexible cords .............................................................. 11
Terminals for external conductors ................................................................................ 11
Provision for earthing ................................................................................................... 11
Screws and connections .............................................................................................. 11
Creepage distances, clearances and distances through insulation ................................ 11
Annexes ............................................................................................................................. 14
Annex I (informative)  Measurement of noise and vibration emissions .................................. 14
Annex K (normative)  Battery tools and battery packs .......................................................... 18
Annex L (normative)  Battery tools and battery packs provided  with mains connection 
or non-isolated sources ....................................................................................................... 19
Bibliography ....................................................................................................................... 20
Figure 101 – Examples of cutting heads with basic dimensions ............................................ 12
Figure 102 – Test probe ...................................................................................................... 13
Figure I.101 – Test set-up for planers .................................................................................. 16
Figure I.102 – Positions of transducers ............................................................................... 17
Table 4 – Required performance levels ................................................................................. 8
Table I.101 – Test conditions .............................................................................................. 14

<!-- 第 5 页 -->
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
ELECTRIC MOTOR-OPERATED HAND-HELD TOOLS, TRANSPORTABLE
TOOLS AND LAWN AND GARDEN MACHINERY – SAFETY –
Part 2-14: Particular requirements for hand-held planers
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising 
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote 
international co-operation on all questions concerning standardization in the electrical and electronic fields. To 
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, 
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC 
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested 
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely 
with the International Organization for Standardization (ISO) in accordance with conditions determined by 
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international 
consensus of opinion on the relevant subjects since each technical committee has representation from all 
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National 
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC 
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any 
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications 
transparently to the maximum extent possible in their national and regional publications. Any divergence 
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in 
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity 
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any 
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and 
members of its technical committees and IEC National Committees for any personal injury, property damage or 
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and 
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC 
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is 
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of 
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 62841-2-14 has been prepared by IEC technical committee 116: 
Safety of motor-operated electric tools.
The text of this standard is based on the following documents:
FDIS 
Report on voting
116/222/FDIS 
116/236/RVD
Full information on the voting for the approval of this standard can be found in the report on 
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
This Part 2-14 is to be used in conjunction with the first edition of IEC 62841-1 (2014).

<!-- 第 6 页 -->
This Part 2-14 supplements or modifies the corresponding clauses in IEC 62841-1, so as to 
convert it into the IEC standard: Particular requirements for hand-held planers.
Where a particular subclause of Part 1 is not mentioned in this Part 2-14, that subclause 
applies as far as relevant. Where this standard states “addition”, “modification” or 
“replacement”, the relevant text in Part 1 is to be adapted accordingly.
The following print types are used:
– 
requirements: in roman type;
– 
test specifications: in italic type;
– 
notes: in small roman type.
The terms defined in Clause 3 are printed in bold typeface.
Subclauses, notes and figures which are additional to those in Part 1 are numbered starting 
from 101.
A list of all parts of the IEC 62841 series, under the general title: Electric motor-operated 
hand-held tools, transportable tools and lawn and garden machinery – Safety, can be found 
on the IEC website.
The committee has decided that the contents of this publication will remain unchanged until 
the stability date indicated on the IEC website under "http://webstore.iec.ch" in the data 
related to the specific publication. At this date, the publication will be
• 
reconfirmed,
• 
withdrawn,
• 
replaced by a revised edition, or
• 
amended.
A bilingual version of this publication may be issued at a later date.
NOTE The attention of National Committees is drawn to the fact that equipment manufacturers and testing 
organizations may need a transitional period following publication of a new, amended or revised IEC publication in 
which to make products in accordance with the new requirements and to equip themselves for conducting new or 
revised tests.
It is the recommendation of the committee that the content of this publication be adopted for implementation 
nationally not earlier than 36 months from the date of publication.
--`,```,``,,`,,`,,,,``,,`,```,,`-`-`,,`,,`,`,,`---

<!-- 第 7 页 -->
ELECTRIC MOTOR-OPERATED HAND-HELD TOOLS, TRANSPORTABLE
TOOLS AND LAWN AND GARDEN MACHINERY – SAFETY –
Part 2-14: Particular requirements for hand-held planers
Scope
This clause of Part 1 is applicable, except as follows:
Addition:
This part of IEC 62841 applies to planers.
Normative references
This clause of Part 1 is applicable.
Terms and definitions
This clause of Part 1 is applicable, except as follows:
Additional definitions:
3.101 
planer 
tool intended for removing surface material, equipped with a rotating cutting head where the 
axis of rotation of the cutting head is parallel to the plane of the base plate, which is the part 
supporting the planer on the workpiece
Note 1 to entry: The base plate consists of a fixed shoe and an adjustable shoe that determines the depth of cut.
3.102 
lift-off device 
device which keeps the blade(s) from making contact with a flat surface when the base plate 
of the planer is attempted to be placed on the flat surface
3.103 
cutting head 
assembly of blades, cutter block, blade fixing elements, relevant screws and spindle, the 
whole being ready for working
General requirements
This clause of Part 1 is applicable.
General conditions for the tests
This clause of Part 1 is applicable, except as follows:
5.17 Addition:
The mass of the tool includes the cutting head including blades and the dust extraction 
adapter, if any.
--`,```,``,,`,,`,,,,``,,`,```,,`-`-`,,`,,`,`,,`---

<!-- 第 8 页 -->
Radiation, toxicity and similar hazards
This clause of Part 1 is applicable.
Classification
This clause of Part 1 is applicable.
Marking and instructions
This clause of Part 1 is applicable, except as follows:
8.1 Addition:
– 
rated no-load speed.
8.3 Addition:
– 
direction of rotation of the working spindle. This shall be indicated by an arrow, raised or 
sunk, or by other means no less visible and indelible.
8.14.1 Addition:
For planers, the additional safety instructions as specified in 8.14.1.101 shall be given. This 
part may be printed separately from the “General power tool safety warnings”.
8.14.1.101 Safety instructions for planers
a) Wait for the cutter to stop before setting the tool down. An exposed rotating cutter
may engage the surface leading to possible loss of control and serious injury.
b) Hold the power tool by insulated gripping surfaces, because the cutter may contact
its own cord. Cutting a "live" wire may make exposed metal parts of the power tool "live" 
and could give the operator an electric shock.
c) Use clamps or another practical way to secure and support the workpiece to a stable
platform. Holding the workpiece by your hand or against the body leaves it unstable and 
may lead to loss of control.
8.14.2 b) Addition:
101)  instructions on how to adjust the entire range of the depth of cut;
102)  instruction on the correct use of the dust collection system.
8.14.2 c) Addition:
101) information about types of cutting heads which can be used, if applicable;
102)  instructions for the changing of the blades and their adjustment to the correct position;
103)  instruction on how to properly clean/clear the chip ejection opening.
Protection against access to live parts
This clause of Part 1 is applicable.
10 Starting
This clause of Part 1 is applicable.
--`,```,``,,`,,`,,,,``,,`,```,,`-`-`,,`,,`,`,,`---

<!-- 第 9 页 -->
11 Input and current
This clause of Part 1 is applicable.
12 Heating
This clause of Part 1 is applicable.
13 Resistance to heat and fire
This clause of Part 1 is applicable.
14 Moisture resistance
This clause of Part 1 is applicable.
15 Resistance to rusting
This clause of Part 1 is applicable.
16 Overload protection of transformers and associated circuits
This clause of Part 1 is applicable.
17 Endurance
This clause of Part 1 is applicable, except as follows:
17.101 If a lift-off device is provided to meet the requirements of 18.8 or 21.18.1.1, it shall 
be sufficiently durable.
Compliance is checked by a new tool sample completing the following test.
The planer is to be set in horizontal position. The lift-off device is cycled through its 
intended range of operation for 50 000 cycles. This sequence is repeated at a rate not less 
than 10 cycles per minute.
After completion of the cycling test as specified above, the planer shall then comply with 
19.111.
18 Abnormal operation
This clause of Part 1 is applicable, except as follows:
18.8 Replacement of Table 4 by the following:

<!-- 第 10 页 -->
Table 4 – Required performance levels
Type and purpose of SCF 
Minimum Performance
Level (PL)
Power switch – prevent unwanted switch-on  
c
Power switch – provide desired switch-off for planers with lift-off device  
a
Power switch – provide desired switch-off for planers without lift-off device  
b
Any electronic control to pass the test of 18.3 
a
Overspeed prevention to prevent output speed above 130 % of rated no-load speed 
b
Provide desired direction of rotation 
a
Prevent exceeding thermal limits as in Clause 18 
a
Prevent self-resetting as required in 23.3  
b
Lock-off function as required by 21.18.1.2 
b
19 Mechanical hazards
This clause of Part 1 is applicable, except as follows:
19.1 Addition:
For the requirements given in 19.107, 19.108 and 19.109, only the test probe shown in 
Figure 102 is used.
19.4.101 Planers with a mass according to 5.17 exceeding 3 kg shall have at least two 
handles. The auxiliary handle, if any, may also be used for the depth-of-cut setting, provided 
the adjustment of depth of cut is achieved by a rotary action.
Compliance is checked by inspection and by measurement.
19.101 The cutting head shall be cylindrically shaped except for the blades, the gullet and 
the blade clamping means.
The maximum gullet width s shall be
smax = 0,235 d + 7,2 mm
where d is the diameter of the rotating circle of the cutting edges. See Figure 101.
Compliance is checked by inspection and by measurement.
19.102 The blades when aligned with the fixed shoe shall not project by more than 1,1 mm 
radially beyond the cutter block (as per dimension “a” in Figure 101).
Compliance is checked by measurement.
19.103 At any depth of cut, the distance “b” (see Figure 101) between the rotating circle of 
the cutting edges and the trailing edge on the adjustable shoe shall not exceed 5 mm 
measured radially.
Compliance is checked by inspection and by measurement.

<!-- 第 11 页 -->
19.104 The blades shall be secured in the cutter block in such a way that friction alone is not 
relied upon to prevent the radial ejection of the blades.
Compliance is checked by inspection.
19.105 Cutting heads shall be designed and made of such materials that they withstand the 
forces and loads expected in normal use.
Compliance is checked by the following test:
An overspeed test shall be made on a sample cutting head, equipped with blades for the 
largest cutting diameter and the largest cutting edge width, the test speed being 1,5 times the 
rated no-load speed. If applicable, tension elements such as clamping screws shall be 
tightened in accordance with the instructions required by 8.14.2 b).
After the test, the cutting head shall not be deformed or cracked, no screws shall be 
loosened and displacements of separable parts shall be less than specified in the test 
procedure.
The test procedure is as follows:
1) Measure the cutting head dimensions.
2) Bring the cutting head to the rated no-load speed, for 1 min.
3) Stop and re-measure the cutting head; measured displacements of the separable parts of 
the cutting head shall not be greater than 0,15 mm.
4) Bring the cutting head to the test speed, for 1 min.
5) Stop and re-measure the cutting head and compare the results with those obtained from 
step 3. The compared displacements shall not exceed 0,15 mm.
19.106 Clamping screws or bolts shall not project beyond the cutter block as shown in 
Figure 101.
Compliance is checked by inspection.
19.107 It shall not be possible to inadvertently touch rotating parts from the sides of the 
planer, except for the cases covered by 19.108.
Compliance is checked by the following test:
The planer is set to minimum depth of cut and is positioned with the shoes resting on a flat 
surface that extends beyond the planer by at least 100 mm in all directions. Any lift-off 
device is disabled. The accessibility is checked by means of the test probe shown in 
Figure 102 with a force not exceeding 5 N.
19.108 Planers with rabbeting facilities shall be provided with a guard that avoids 
inadvertent contact at the sides with the blades.
NOTE Rabbeting is also known as rebating.
Compliance is checked by inspection and by the following test:
The planer is set to minimum depth of cut and is positioned with the shoes resting on a flat 
surface that extends beyond the planer by at least 100 mm in all directions. Any lift-off 
device is disabled. The accessibility is checked by means of the test probe shown in 
Figure 102 without any force.

<!-- 第 12 页 -->
19.109 It shall not be possible to touch the blades through the chip ejection opening.
Compliance is checked by testing all apertures for chip ejection with the test probe of 
Figure 102. It shall not be possible to touch the blades in the cutting head at any angle of the 
probe.
19.110 Planers shall stop within 10 s after switching off.
Compliance is checked by inspection and by measurement.
19.111 Lift-off device
19.111.1 If a lift-off device is provided to meet the requirements of 18.8 or 21.18.1.1, it 
shall meet the requirements of 19.111.2 and 19.111.3, which are checked only after 
completing the endurance test of 17.101.
19.111.2 If a lift-off device is provided, it shall be designed so that
– 
it is automatically activated, when the planer is lifted up from a horizontal surface; and
– 
the blade(s) do not make contact, when the planer is set at maximum depth of cut in 
accordance with 8.14.2 b) 101) and placed on a horizontal surface.
Compliance is checked by inspection.
19.111.3 A lift-off device shall provide sufficient stability.
Compliance is checked by the following test:
The planer is set to maximum depth of cut in accordance with 8.14.2 b) 101) and with the 
supply cord, if any, removed. The planer is then placed on a flat board of medium density 
fibreboard (MDF) having a density of 650 kg/m3 to 850 kg/m3 that is inclined at an angle of 
10°, such that the rear of the planer is nearest to the high side of the board and allowed to 
rest freely for 10 s to 12 s. During the test, the planer is permitted to slide, however, the lift-
off device shall not collapse such that the planer blades come into contact with the board.
20 Mechanical strength
This clause of Part 1 is applicable.
21 Construction
This clause of Part 1 is applicable, except as follows:
21.18.1.1 Addition:
Planers whose blade(s) make contact with a flat surface when the base plate is placed on the 
flat surface and without a lift-off device are regarded as tools having a risk associated with 
continued locked-on operation.
NOTE In Europe (EN 62841-2-14), the above text is replaced by the following:
For planers, the switch shall not have any locking device to lock it in the “on” position.
21.18.1.2 Addition:
Planers are regarded as tools having a risk associated with inadvertent starting.

<!-- 第 13 页 -->
21.35 This subclause of Part 1 is applicable.
22 Internal wiring
This clause of Part 1 is applicable.
23 Components
This clause of Part 1 is applicable.
24 Supply connection and external flexible cords
This clause of Part 1 is applicable.
25 Terminals for external conductors
This clause of Part 1 is applicable.
26 Provision for earthing
This clause of Part 1 is applicable.
27 Screws and connections
This clause of Part 1 is applicable.
28 Creepage distances, clearances and distances through insulation
This clause of Part 1 is applicable.

<!-- 第 14 页 -->
a) Example 1 and explanation of basic dimensions
b) Example 2
Key
fixed shoe
adjustable shoe
trailing edge
a 
radial projection of the blades beyond the cutter block
b 
distance between the rotating circle of the cutting edges and the trailing edge of the adjustable shoe
d 
diameter of the rotating circle of the cutting edges
s 
gullet width
Figure 101 – Examples of cutting heads with basic dimensions
IEC
IEC
--`,```,``,,`,,`,,,,``,,`,```,,`-`-`,,`,,`,`,,`---

<!-- 第 15 页 -->
∅35±0,2
∅8
Key
handle section
test section
probe’s flange
Dimensions in millimetres
−0,05
∅12 
+0
R6 +0
−0,05
50±0,2 
IEC
Figure 102 – Test probe

<!-- 第 16 页 -->
Annexes
The annexes of Part 1 are applicable except as follows.
Annex I 
(informative)
Measurement of noise and vibration emissions
NOTE In Europe (EN 62841-2-14), Annex I is normative.
I.2 Noise test code (grade 2)
This clause of Part 1 is applicable except as follows:
I.2.4 Installation and mounting conditions of the power tools during noise tests
Addition:
Planers are held and used as specified in I.2.5.
I.2.5 Operating conditions
Addition:
Planers are tested under load observing the conditions shown in Table I.101.
The temperature requirements of 5.6 are not applicable.
Table I.101 – Test conditions
Orientation 
Planing along a horizontal surface of a softwood workpiece free of knots and having a 
residual moisture not exceeding 14 %.
To prevent absorption of airborne noise, the resilient material shall either
– 
not extend the contact area between workpiece and test bench; or
– 
be of non airborne-sound absorbing material, such as rubber.
If a parallel guide is provided, this may be used.
NOTE Examples of softwood are pine and fir.
Tool bit 
Blade as specified for planing softwood. The depth of cut shall be set to maximum 
capacity.
Feed force 
As necessary to achieve a constant feed rate resulting in 10 s to 15 s planing time for one 
test cycle (600 mm). Equal forces are applied to the main handle and the auxiliary 
handle, if applicable, avoiding excessive gripping forces.
Test cycle 
Planing the complete length of 600 mm at maximum depth of cut.
--`,```,``,,`,,`,,,,``,,`,```,,`-`-`,,`,,`,`,,`---
The workpiece shall have a minimum length of 600 mm, a minimum height of 90 mm and 
a width B, where B is the maximum planing width of the tool minus (15 ± 2) mm.
The workpiece shall be supported on resilient material and fixed vertically by screws, 
clamps, air cylinders or the like to a test bench of Figure I.1, see Figure I.101. For the 
fixing, the workpiece may have recesses or the like; an example is shown in Figure I.101. 
The resilient material shall be mounted so that it does not have any significant resonance 
in the frequency range that can influence the test result.
However, if it is not possible to plane the whole surface length within the given time, 
because the planer may stall, a longer test cycle time is permitted using a feed force as 
high as possible without stalling the planer.
The measurement takes place over a length of approximately 400 mm that does not 
include the ends of the workpiece.

<!-- 第 17 页 -->
I.3 Vibration
This clause of Part 1 is applicable except as follows:
I.3.3.2 Location of measurement
Addition:
Figure I.102 shows the positions on the main handle and the auxiliary handle, if applicable.
I.3.5.3 Operating conditions
Addition:
Planers are tested under load according to the conditions shown in Table I.101.
I.3.6.2 Declaration of the vibration total value
Addition:
The vibration total value ah of the handle with the highest emission and the uncertainty K shall 
be declared.
--`,```,``,,`,,`,,,,``,,`,```,,`-`-`,,`,,`,`,,`---

<!-- 第 18 页 -->
Key
test bench of Figure I.1
resilient material
workpiece
fixing means (e.g. clamps)
IEC 62841-2-14:2015 © IEC 2015
IEC
a) Side view
IEC
b) Front view
Figure I.101 – Test set-up for planers

<!-- 第 19 页 -->
IEC
Figure I.102 – Positions of transducers

<!-- 第 20 页 -->
Annex K 
(normative)
Battery tools and battery packs
K.1 Scope
Addition:
All clauses of this Part 2-14 apply unless otherwise specified in this annex.
K.8.14.1.101 Item b) is not applicable.
K.12.2.1 This subclause is not applicable.
K.20.5 This subclause is not applicable.
K.21.18.1.2 Addition:
Two separate and dissimilar actions shall be necessary before the motor is switched on (e.g. 
a power switch which has to be pushed in before it can be moved laterally to close the 
contacts to start the motor). It shall not be possible to achieve these two actions with a single 
grasping motion or a straight line motion.
Compliance is checked by inspection and by manual test.
K.21.30 This subclause is not applicable.
NOTE In Europe (EN 62841-2-14), the following additional subclause applies:
K.21.18.Z101 Isolation device
Planers with an integral battery shall be equipped with an isolation device to prevent the risk of injury from 
mechanical hazards during user maintenance that
– 
ensures a reliable disconnection of at least one pole of the battery from the relevant load(s);
– 
has a reliable mechanical link between the manual control and the disconnecting element(s);
– 
is equipped with an unambiguous indication of the state of the disconnection device which corresponds to each 
position of its manual control (actuator);
– 
protects against accidental reconnection.
NOTE 1 Examples of methods to achieve this disconnection include removable jumpers, removable batteries or a 
electromechanical power switch with a direct mechanical link between the actuator and the contact.
NOTE 2 The risk of accidental reconnection for a power switch is addressed by the requirement of 21.18.1.2. 
The other examples in Note 1 achieve this by the necessary actions for reconnection.
Compliance is checked by inspection.

<!-- 第 21 页 -->
Annex L 
(normative)
Battery tools and battery packs provided  
with mains connection or non-isolated sources
L.1 Scope
Addition:
All clauses of this Part 2-14 apply unless otherwise specified in this annex.
L.21.18.1.2 Addition:
Two separate and dissimilar actions shall be necessary before the motor is switched on (e.g. 
a power switch which has to be pushed in before it can be moved laterally to close the 
contacts to start the motor). It shall not be possible to achieve these two actions with a single 
grasping motion or a straight line motion.
Compliance is checked by inspection and by manual test.
NOTE In Europe (EN 62841-2-14), the following additional subclause applies:
L.21.18.Z101 Isolation device
Planers with an integral battery shall be equipped with an isolation device to prevent the risk of injury from 
mechanical hazards during user maintenance that
– 
ensures a reliable disconnection of at least one pole of the battery from the relevant load(s);
– 
has a reliable mechanical link between the manual control and the disconnecting element(s);
– 
is equipped with an unambiguous indication of the state of the disconnection device which corresponds to each 
position of its manual control (actuator);
– 
protects against accidental reconnection.
NOTE 1 Examples of methods to achieve this disconnection include removable jumpers, removable batteries or a 
electromechanical power switch with a direct mechanical link between the actuator and the contact.
NOTE 2 The risk of accidental reconnection for a power switch is addressed by the requirement of 21.18.1.2. 
The other examples in Note 1 achieve this by the necessary actions for reconnection.
Compliance is checked by inspection.

<!-- 第 22 页 -->
Bibliography
The bibliography of Part 1 is applicable.
___________
--`,```,``,,`,,`,,,,``,,`,```,,`-`-`,,`,,`,`,,`---

<!-- 第 24 页 -->
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION 
3, rue de Varembé
PO Box 131 
CH-1211 Geneva 20
Switzerland 
Tel: + 41 22 919 02 11 
Fax: + 41 22 919 03 00
info@iec.ch 
www.iec.ch